background image

 

death, serious injury or considerable material damage.

Qualified personnel

Installation and operation of this equipment described in this manual may only be performed by 
qualified personal.
Only people that are authorized to install, connect and use this equipment and have the proper 
knowledge   about   labeling   and   grounding   electrical   equipment   and   circuits   and   can   do   so 
according to safety and regulatory standards are considered qualified personnel in the manual.

Use for the intend purpose

The equipment (device, module) may only be used for the application cases specified in the 
catalog and the user manual and only in connection with devices and components recommended 
and approved by YTL.

Exclusion of liability

We have checked the contents of this publication and every effort has been made to ensure that 
the descriptions are as accurate as possible. However, deviations from the description cannot be 
completely ruled out, so that no liability can be accepted for any errors or omissions in the 
information given. The data in this manual is checked regularly and the necessary corrections will 
be included in subsequent editions. If you have any suggestions, pls let us know.

Subject to technical modifications without notice.

Copyright

Copyright Zhejiang Yongtailong Electronic Co., Ltd. April 2013 All rights Reserved.
It is prohibited to pass on or copy this document or to use or disclose its contents without our  
express permission. Any duplication is a violation of the law and subject to criminal and civil 
penalties. All rights reserved, particularly for pending or approved patents award or registered 
trademarks.

General Warning

After   removing   the   packaging   make   sure   the   integrity   of   the   unit.   If   in   doubt   don't   use   the 

11

Содержание D111031-01

Страница 1: ...1 Introduction 2 Technical Parameters 3 Description 4 Display 5 Connection Diagram 6 Meter Dimension 7 Installation Instruction Single Phase Two Wire Meter User Manual for D111031 01...

Страница 2: ...can up to 50A Counter display 99999 9kWh Degree of Protection IP51 indoor meter 2 2 Technical Parameters Voltage 230V 20 Current 0 25 5 30 A 0 25 5 32 A 0 25 5 40 A 0 25 5 45 A 0 25 5 50 A Accuracy cl...

Страница 3: ...ture range 25 55 Flashing red Impulse indication Average humidity value of year 75 Non Condensing Maximal value 95 3 Description Material Case ABS PC Alloy material Hook ABS material 4 Display Counter...

Страница 4: ...6 Meter Dimensions 3...

Страница 5: ...Height 63mm Width 19mm Length 116mm 4...

Страница 6: ...truction Choose 35mm standard Din Rail the length is confirmed by yourself fixed them in the location which are waiting for installation Push down the clip under the bottom of the meter for a gear see...

Страница 7: ...6 After push down the clip...

Страница 8: ...Fig 1 Fig 2 Put the meter into the Din rail as per Fig 3 then push up the clip for a gear install meter to the Din rail see Fig 4 7...

Страница 9: ...Fig 3 Fig 4 Recommended wire For your reference 8...

Страница 10: ...arrying capacity A BX BLX BV BLV 1 1 13 1 20 18 1 1 37 1 5 25 22 1 1 76 2 5 33 25 30 23 1 2 24 4 42 33 40 30 1 2 73 6 55 42 50 40 7 1 33 10 80 55 75 55 7 1 76 16 105 80 100 75 7 2 12 25 140 105 130 10...

Страница 11: ...is equipment module device because special operating conditions local code requirements or local regulations may necessitate further measures However it does contain information which must be adhered...

Страница 12: ...and every effort has been made to ensure that the descriptions are as accurate as possible However deviations from the description cannot be completely ruled out so that no liability can be accepted...

Страница 13: ...cal staff Failure to comply with the above may compromise the device safety Warranty The manufactory will repair or exchange the products while the lead seal is still exited within 18 months when disc...