background image

i

T H I S   PA G E   L E F T   I N T E N T I O N A L L Y   B L A N k

WA R R A N T Y

The YSI Professional OBOD

®

 (ProOBOD

TM

) probe and cable assembly is warranted

for two (2) years from date of purchase by the end user against defects in materials and 

workmanship, exclusive of batteries and any damage caused by defective batteries. 

ProOBOD sensor caps are warranted for one (1) year from date of purchase by the end 

user against defects in material and workmanship.  ProOBOD systems (instrument 

& cable/probe assemblies) are warranted for 90 days from date of purchase by the 

end  user  against  defects  in  material  and  workmanship  when  purchased  by  rental 

agencies for rental purposes.  Within the warranty period, YSI will repair or replace, 

at its sole discretion, free of charge, any product that YSI determines to be covered 

by this warranty.

To  exercise  this  warranty,  call  your  local  YSI  representative,  or  contact  YSI 

Customer Service in Yellow Springs, Ohio at +1 937 767-7241, 800-897-4151 or visit 

www.YSI.com for a Product Return Form.  Send the product and proof of purchase, 

transportation prepaid, to the Authorized Service Center selected by YSI.  Repair 

or  replacement  will  be  made  and  the  product  returned,  transportation  prepaid.  

Repaired or replaced products are warranted for the balance of the original warranty 

period, or at least 90 days from date of repair or replacement.

LIMITATION OF WARRANTY

This Warranty does not apply to any YSI product damage or failure caused by: 

Failure to install, operate or use the product in accordance with YSI’s written 

1. 

instructions; 

Abuse or misuse of the product;

2.

Failure to maintain the product in accordance with YSI’s written instructions

3.

or standard industry procedure;

Any improper repairs to the product;

4.

Use  by  you  of  defective  or  improper  components  or  parts  in  servicing  or

5.

repairing the product;

Modification of the product in any way not expressly authorized by YSI.

6.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR 

IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS 

FOR A PARTICULAR PURPOSE.  YSI’S LIABILITY UNDER THIS WARRANTY 

IS  LIMITED  TO  REPAIR  OR  REPLACEMENT  OF  THE  PRODUCT,  AND  THIS 

SHALL  BE  YOUR  SOLE  AND  EXCLUSIVE  REMEDY  FOR  ANY  DEFECTIVE 

PRODUCT  COVERED  BY  THIS  WARRANTY.    IN  NO  EVENT  SHALL  YSI  BE 

LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL 

DAMAGES  RESULTING  FROM  ANY  DEFECTIVE  PRODUCT  COVERED  BY 

THIS WARRANTY.

Содержание WE KNOW ProOBOD

Страница 1: ...USER MANUAL ...

Страница 2: ...ntenance and Storage 8 Updating Instrument and Probe Firmware 8 Sensor Maintenance Dissolved Oxygen 8 Sensor Maintenance Temperature 11 Sensor Storage 12 Troubleshooting 12 Dissolved Oxygen Readings 12 Help 13 Error Status messages 13 Restore Default Calibration Values 14 Probe Specifications 15 Accessories Parts List 16 Declaration of Conformity 17 Recycling 19 Contact Information 20 Ordering and...

Страница 3: ...elected by YSI Repair or replacement will be made and the product returned transportation prepaid Repaired or replaced products are warranted for the balance of the original warranty period or at least 90 days from date of repair or replacement LIMITATION OF WARRANTY This Warranty does not apply to any YSI product damage or failure caused by Failure to install operate or use the product in accorda...

Страница 4: ...tional outlet adapters are also included The ProOBOD sensor measures dissolved oxygen in water using lifetime luminescence technology and uses a digital signal to send information between the instrument and probe The probe features a stirrer and motor to aid in sample movement to keep solids from settling at the bottom of the sample bottle and to speed up the response of the sensor Key advantages ...

Страница 5: ...nstruction sheet is important because it contains the calibration coefficients for your sensor cap After using this sheet for general probe setup be sure to store it in a safe place in case you need to reload these calibration coefficients in the unlikely event that they are ever deleted from the instrument and probe Note A new cable probe assembly already has a sensor cap installed and the sensor...

Страница 6: ...r cap needs replaced See the Sensor Maintenance Dissolved Oxygen section of this manual or the instruction sheet included with the replacement sensor cap for instructions on updating the Sensor Cap Coefficients When updating the Coefficients the sensor cap serial will be updated automatically based on your entries The Temperature Coefficient should not be modified unless instructed by YSI Technica...

Страница 7: ...nd then press Cal to complete the calibration The message line at the bottom of the screen will display Calibrating Channel followed by Calibration Successful Press Esc to cancel the calibration i Temperature All ProOBOD probes have built in temperature sensors Temperature calibration is not required nor is it available To set the units press the Probe key on the ProODO instrument and select Displ...

Страница 8: ...en replacing a Sensor Cap the Sensor Cap Coefficients must be manually updated in the ProODO instrument The instruction sheet shipped with the replacement OBOD sensor cap includes the calibration coefficients that are specific to your Sensor Cap u IMPORTANT Be sure to save the OBOD Sensor Cap instruction sheet in case you need to reload the calibration coefficients The replacement OBOD Sensor Cap ...

Страница 9: ...Calibration Code has been entered correctly press enter to confirm Highlight K2 through KC in turn and use the 5 numeric entry screen to enter the corresponding new coefficient from the Calibration Code label as described in step 4 Press enter after each entry and then proceed to the next K selection After all the new coefficients have been entered highlight 6 Update Coefficients and press enter A...

Страница 10: ... sensor cap and then recalibrate If you are still getting erroneous dissolved oxygen readings try replacing the sensor cap and then recalibrate If the erroneous readings continue contact YSI Technical Support to help determine the next step Inspecting the Sensor Cap for Damage Caution Avoid touching the sensing end of the sensor cap during the following maintenance procedures If DO measurements se...

Страница 11: ... Values Occasionally the instrument may need to have the factory calibration default values restored To perform a factory reset press Calibrate highlight Restore Default Cal and press enter Select the parameter you wish to restore either DO or Barometer and press enter After selecting barometer or DO you will be asked to confirm the operation Highlight Yes and press enter P robe S pecifications Th...

Отзывы: