TROUBLESHOOTING
This table provides the cause and corrective actions against most commonly
occurred problems
Problem
Cause
Corrective Action
Lamp not working
- Lamp faults
Replace Power section
- Each connector not well connected
Repair faulty circuits
- Wiring(Polarity) of the lamp is fault
Replace Power section
- Faulty isolated transformer
Replace isolated
transformer
Color of the lighting
looking different than
other lightings
- Lamp fault
Replace Power section
Lamp looking dimmer
than other lamps.
- Lamp fault
Replace the lamp
- Reflector fault
Replace the reflector
- Faulty isolated transformer
Replace isolated
transformer
- Polluted lens
Clean the lens
- Power section fault
Replace Power section
Intensity not changed - Check the specification of Power