Young 86004 Скачать руководство пользователя страница 6

 Page 3

86004-90(G)

5.3.4  NMEA

NMEA format provides continuous wind measurements in standard 

NMEA marine sentences at 4800 baud. Use RS-485 OUTPUT ONLY 

serial output mode with YOUNG Model 06206 Marine Wind Tracker 

or other NMEA-capable device.

 

NMEA FORMAT

 

$WIMWV,ddd,R,www.w,N,A*cc<CR><LF>

 

where

 

ddd

 

= Wind direction (degrees)

 

www.w

  

= Wind speed (knots)

 

*

 

= Asterisk (ASCII 42)

 

cc

 

= Checksum

 

<CR><LF>

  = Carriage return, line feed (ASCII 13, 10)

CHECKSUM  is  the  two-character  printable  hexadecimal  value  

generated by taking the exclusive-or of all characters between 

'$'

 

and 

'*'

.

5.4   LOW  POWER OPERATION

Average current consumption with default settings is about 20 mA. 

This configuration uses minimal power and enables all features even 

though they may not be used. This is suitable for many low power 

applications.
To reduce current consumption further, additional strategies include 

disabling unused outputs, using polled serial operation, increasing 

the output interval, and limiting the sample count to the minimum 

optimal  number.  Faster  baud  rates  also  reduce  power  by  limiting 

transmit duration.

6.0 SETTING OUTPUTS AND OPERATING 

PARAMETERS

6.1    SENSOR  CONFIGURATION  WITH  86SETUP  PROGRAM 

(RECOMMENDED)

The YOUNG 86SETUP program is available from the factory web site 

at www.youngusa.com. It provides an easy method for checking and 

configuring sensor operation. Install the program on a Windows PC 

and follow instructions that appear on the program screen to retrieve 

current sensor settings or send new settings.

6.2  SENSOR CONFIGURATION USING A GENERAL-

       PURPOSE COMMUNICATIONS PROGRAM

A general purpose text-based serial communications program like 

HyperTerminal may be used to manually configure the sensor by 

sending simple text commands.
The YOUNG sensor and communication program must operate at 

the  same  baud  rate  and  be  properly  connected.  Sensor  RS-232 

mode must be enabled. See the RS-232 Wiring diagram, Fig A3,  

in Appendix A.
Factory default sensor baud rate is 9600, but may be set to 1200, 

4800, 19200 or 38400. Configure the serial communications program 

for NO handshaking and 1 start, 8 data, 1 stop bit.
The sensor must be in COMMAND MODE in order to set parameters. 

Enter COMMAND MODE by sending three ESC characters (ASCII 

27) in quick succession while the sensor is running. When the sensor 

is in COMMAND MODE, it sends a '>' prompt character indicated 

that it is ready to accept commands.
If the prompt does not appear after sending three ESC characters, 

re-check  wiring  and  communication  program  setup.  If  the  sensor 

baud rate is unknown, try sending the ESC characters at each of 

the five available baud rates (1200, 4800, 9600, 19200 and 38400). 

It  is  also  possible  that  sensor  parameters  have  been  purposely 

configured to disable RS-232 mode. If this the case, the following 

method must be used.

In order to provide access under all conditions, the sensor always 

begins operation at power up with serial communications set to 38400 

baud and RS-232 connections enabled. Immediately after power up, 

there is a short time window in which to send the ESC characters 

and enter COMMAND MODE.
To use this feature, set your serial communication program baud rate 

to 38400. Remove power then wait 5 seconds. Re-apply power to 

the sensor. The sensor will transmit four asterisks immediately after 

power up. After the asterisks appear, send three ESC characters. 

The COMMAND MODE 

'>'

 prompt should appear.

6.3  COMMAND OVERVIEW

After the '>' prompt appears, send 

'??'

 to display a list of available 

commands. Send 

'RPTV'

 to report current settings. (Note that some 

values in the report are for factory settings cannot be changed by 

the user.) 
Commands are case sensitive and the exact format must be used. 

For example, the 

SET01nn

 command requires two digits for the serial 

format code. If you send 

SET014

 instead of 

SET0104

 the sensor will 

reject the command and indicate an error.  End all commands with 

a carriage return (ASCII 13). In HyperTerminal, do this by pressing 

the ENTER key.
After  receiving  the  carriage  return,  the  sensor  will  evaluate  the 

command. Valid commands will be executed. Current settings can be 

evaluated at any time by sending RPTV to get a new report.

IMPORTANT NOTE:

The YOUNG 86SETUP program automatically saves all 

settings to flash memory when they are sent to the sensor. 

Settings that are changed manually must be saved to flash 

with the SET77 command.

Содержание 86004

Страница 1: ...AL INSTRUMENTS INSTRUCTIONS R M YOUNG COMPANY 2801 AERO PARK DRIVE TRAVERSE CITY MICHIGAN 49686 USA TEL 231 946 3980 FAX 231 946 4772 WEB www youngusa com PN 86004 90 REV G092117 ULTRASONIC ANEMOMETER...

Страница 2: ...G Wind Tracker Display 2 5 3 Serial Output Formats and Protocols 2 5 4 Low Power Operation 3 6 0 SETTING SERIAL OUTPUTS AND OPERATING PARAMETERS 6 1 Setup using YOUNG 86SETUP program 3 6 2 Setup using...

Страница 3: ......

Страница 4: ...ady to use Unless otherwise specified the sensor is configured as follows FACTORY DEFAULT CONFIGURATION Analog Voltage Outputs Channel VI1 Wind Speed 0 5000 mV 0 100 m sec Channel VI2 Wind Direction 0...

Страница 5: ...uts since they share connection terminals in the junction box Analog outputs may be configured for either Polar speed and direction or Cartesian UV output format For voltage output with cable lengths...

Страница 6: ...d 1 start 8 data 1 stop bit The sensor must be in COMMAND MODE in order to set parameters Enter COMMAND MODE by sending three ESC characters ASCII 27 in quick succession while the sensor is running Wh...

Страница 7: ...direction to minimize erratic wind direction indications at very low wind speeds This allows the sensor output to mimic a mechanical wind vane that retains its orientation when there is no wind Wind b...

Страница 8: ...sted settings Not all possible setting combinations are shown Using YOUNG 86SETUP program for changing parameters is recommended See wiring diagrams for jumper settings 7 1 FACTORY DEFAULT RS 232 Enab...

Страница 9: ...Page 6 86004 90 G APPENDIX A WIRING CONNECTIONS...

Страница 10: ...Page 7 86004 90 G APPENDIX A WIRING CONNECTIONS...

Страница 11: ...Page 8 86004 90 G APPENDIX A WIRING CONNECTIONS...

Страница 12: ...TH 270 90 180 EXAMPLE WIND AT 45 POLAR WIND SPEED WIND DIRECTION 0 V m s WIND FROM NORTH CARTESIAN U V U m s WIND FROM EAST 86052 OPTIONAL BIRD WIRE ASSEMBLY R M YOUNG COMPANY 2801 Aero Park Drive Tra...

Отзывы: