85000-90

MODEL 85000

ULTRASONIC ANEMOMETER

1.0  SPECIFICATIONS

WIND SPEED

Range: 

0-70 m/s (156 mph)

Resolution: 

0.1 m/s

Accuracy: 

0 to 30 m/s, ±2% or 0.1m/s 

30 to 70 m/s, ±3%

WIND DIRECTION

Azimuth Range: 

0-360 degrees

Resolution: 

1 degree

Accuracy: 

± 2 degrees

SERIAL OUTPUT

Type: 

RS-232, RS-485, SDI-12

Formats: 

ASCII Text (polled and continuous)

 

RMYT (Wind Tracker)

 

NMEA

 

SDI-12 (v1.3)

Baud Rates: 

1200, 4800, 9600, and 38400 baud

ANALOG VOLTAGE OUTPUT

Polar

Wind Speed: 

0 to 5000 mV (0 to 100 m/s)

Wind Direction: 

0 to 5000 mV (0 to 360° or 0 to 540°)

Cartesian (UV)

U and V: 

0 to 5000 mV  (-100 m/s to +100 m/s)

GENERAL

Output rate:  

1 Hz  typical (selectable)

Power Supply:  

9 to 16 VDC,

 

150 mA max

Dimensions: 

34 cm high x 17 cm wide

Weight:  

0.7 kg (1.5 lb)

Shipping Weight:  1.6 kg (3.5 lb)

2.0 INTRODUCTION

The YOUNG 85000  Ultrasonic Anemometer is a 2-axis, no-

moving-parts wind sensor.  It is ideal for general meteorological 

applications requiring accurate and reliable measurement. 

The sensor features wide operating range, compact size, easy 

installation and low power operation.  Analog and digital signal 

outputs are available in several popular formats.

The 85000 measures wind based on the transit time of ultrasonic 

pulses between four transducers. Air flow alters the transit 

time  which is used to calculate flow velocity. Wind direction is 

determined from relative velocities along each acoustic path.

Measurement  results  are  available  as  calibrated  voltage 

output signals or serial data using RS-232, RS-485, or SDI-12 

connections. Continuous output or polled operation may be used. 

Serial formats  may be selected for direct connection to YOUNG 

Wind Tracker displays, marine NMEA systems, SDI-12 data 

loggers, and ASCII serial communication programs.

Operating parameter options are selected using a simple setup 

program provided. All 85000 settings are stored internally in non-

volatile memory.

The sensor is constructed using UV-stabilized thermoplastic, 

stainless steel, and anodized aluminum for superior environmental 

resistance.     It is easily mounted on standard 1 inch (IPS) pipe. 

An orientation ring preserves mounting position when the sensor 

is removed.

3.0 INITIAL CHECKOUT

Carefully unpack the unit and inspect for physical damage. Any 

damage should be reported to the shipper. The 85000 arrives fully 

calibrated and ready to use. As supplied, the sensor is configured 

as follows:

 

    FACTORY DEFAULT CONFIGURATION: 

       

         Serial Output:

  

- RMYT Format

  

- RS-232

 

- RS-485 Output Only

 

- 9600 baud

        Analog Voltage Outputs:

 

- Channel V1:  Wind Speed

 

 

        0-5000 mV = 0-100 m/sec

 

- Channel V2:  Wind Direction

 

 

        0-5000mV = 0-360 Deg

These settings will permit direct serial connection to the Young 

Model 06201 Wind Tracker and connection of the voltage outputs 

to a voltage measuring device or datalogger.  For other available 

serial or voltage output configurations refer to the appropriate 

sections of the manual.

A simple operational check of the sensor may be performed as 

follows: (Requires Model 06201 Wind Tracker)

3.1  Remove junction box cover and connect power and 

signal wires to terminals as indicated in WIRING 

CONNECTIONS (APPENDIX A).  Supply voltage must 

be 9 to 16 VDC.

Содержание 85000

Страница 1: ...AL INSTRUMENTS INSTRUCTIONS R M YOUNG COMPANY 2801 AERO PARK DRIVE TRAVERSE CITY MICHIGAN 49686 USA TEL 231 946 3980 FAX 231 946 4772 WEB www youngusa com PN 85000 90 REV J110410 ULTRASONIC ANEMOMETER...

Страница 2: ...peration 4 6 0 SETTING SERIAL OUTPUTS AND OPERATING PARAMETERS 6 1 Setup using Young the 2DSETUP program 4 6 2 Setup using terminal Program 4 6 3 Command Overview 4 6 4 Command Details 5 7 0 EXAMPLE S...

Страница 3: ......

Страница 4: ...data using RS 232 RS 485 or SDI 12 connections Continuous output or polled operation may be used Serial formats may be selected for direct connection to YOUNG Wind Tracker displays marine NMEA systems...

Страница 5: ...the mounting post band clamp to secure the position DO NOT OVER TIGHTEN 4 2 4 Slide the orientation ring up so its guide pin is fully engaged in the sensor mounting post notch Tighten the orientation...

Страница 6: ...Wind Tracker or other NMEA capable device NMEA FORMAT WIMWV ddd R www w N A cc CR LF where ddd Wind direction degrees www w Wind speed knots Asterisk ASCII 42 cc Checksum CR LF Carriage return line f...

Страница 7: ...AM If desired a serial communications program like HyperTerminal may be used Parameters are set using simple commands A limited number of parameters may also be set using SDI 12 commands For serial co...

Страница 8: ...tomatically changed as listed below FORMAT ADDITIONAL CODE PARAMETERS CHANGED 01 RMYT BAUD 9600 OUTPUT MODE 07 THRESHOLD 25 cm s OUTPUT DELAY 01 SAMPLE COUNT 31 02 ASCII 03 ASCII POLLED None 04 NMEA B...

Страница 9: ...d direction or Cartesian UV form This setting also determines the whether voltage outputs are in Polar or Cartesian format 00 Polar 01 Cartesian UV 6 4 14 SET14n SET VOLTAGE OUTPUT STATUS Serial ASCII...

Страница 10: ...oduct has been tested and shown to comply with European CE requirements for the EMC Directive Please note that shielded cable must be used Declaration of Conformity R M Young Company 2801 Aero Park Dr...

Страница 11: ...Page 8 85000 90 APPENDIX A WIRING CONNECTIONS...

Страница 12: ...Page 9 85000 90 APPENDIX A WIRING CONNECTIONS...

Страница 13: ...Page 10 85000 90 APPENDIX A WIRING CONNECTIONS...

Страница 14: ...Page 11 85000 90 APPENDIX A WIRING CONNECTIONS...

Страница 15: ...Page 12 85000 90 APPENDIX A WIRING CONNECTIONS...

Страница 16: ...TION U V U WIND FROM EAST V WIND FROM NORTH EXAMPLE WIND AT 45 OPTIONAL 85052 BIRD WIRE ASSY WHEN PROPERLY ALIGNED JUNCTION BOX FACES SOUTH INSTALL VERTICALLY AS SHOWN TO AVOID MOISTURE DAMAGE TO CIRC...

Отзывы: