 Page 7

85000-90

8.0  WARRANTY

This  product  is  warranted  to  be  free  of  defects  in  materials  and 

construction for a period of 12 months from date of initial purchase. 

Liability is limited to repair or replacement of defective item. A copy 

of the warranty policy may be obtained from R. M. Young Company.

9.0  CE COMPLIANCE

This product has been tested and shown to comply with European 

CE requirements for the EMC Directive. Please note that shielded 

cable must be used.

Declaration of Conformity

R. M. Young Company

2801 Aero Park Drive

Traverse City, MI 49686 USA

Model  85000

The undersigned hereby declares on behalf of R. M.

Young Company that the above-referenced product, to

which this declaration relates, is in conformity with the

provisions of:

Council Directive 2004/108/EC (December 15, 2004)

on Electromagnetic Compatibility

David Poinsett

R&D Manager

Содержание 85000

Страница 1: ...AL INSTRUMENTS INSTRUCTIONS R M YOUNG COMPANY 2801 AERO PARK DRIVE TRAVERSE CITY MICHIGAN 49686 USA TEL 231 946 3980 FAX 231 946 4772 WEB www youngusa com PN 85000 90 REV J110410 ULTRASONIC ANEMOMETER...

Страница 2: ...peration 4 6 0 SETTING SERIAL OUTPUTS AND OPERATING PARAMETERS 6 1 Setup using Young the 2DSETUP program 4 6 2 Setup using terminal Program 4 6 3 Command Overview 4 6 4 Command Details 5 7 0 EXAMPLE S...

Страница 3: ......

Страница 4: ...data using RS 232 RS 485 or SDI 12 connections Continuous output or polled operation may be used Serial formats may be selected for direct connection to YOUNG Wind Tracker displays marine NMEA systems...

Страница 5: ...the mounting post band clamp to secure the position DO NOT OVER TIGHTEN 4 2 4 Slide the orientation ring up so its guide pin is fully engaged in the sensor mounting post notch Tighten the orientation...

Страница 6: ...Wind Tracker or other NMEA capable device NMEA FORMAT WIMWV ddd R www w N A cc CR LF where ddd Wind direction degrees www w Wind speed knots Asterisk ASCII 42 cc Checksum CR LF Carriage return line f...

Страница 7: ...AM If desired a serial communications program like HyperTerminal may be used Parameters are set using simple commands A limited number of parameters may also be set using SDI 12 commands For serial co...

Страница 8: ...tomatically changed as listed below FORMAT ADDITIONAL CODE PARAMETERS CHANGED 01 RMYT BAUD 9600 OUTPUT MODE 07 THRESHOLD 25 cm s OUTPUT DELAY 01 SAMPLE COUNT 31 02 ASCII 03 ASCII POLLED None 04 NMEA B...

Страница 9: ...d direction or Cartesian UV form This setting also determines the whether voltage outputs are in Polar or Cartesian format 00 Polar 01 Cartesian UV 6 4 14 SET14n SET VOLTAGE OUTPUT STATUS Serial ASCII...

Страница 10: ...oduct has been tested and shown to comply with European CE requirements for the EMC Directive Please note that shielded cable must be used Declaration of Conformity R M Young Company 2801 Aero Park Dr...

Страница 11: ...Page 8 85000 90 APPENDIX A WIRING CONNECTIONS...

Страница 12: ...Page 9 85000 90 APPENDIX A WIRING CONNECTIONS...

Страница 13: ...Page 10 85000 90 APPENDIX A WIRING CONNECTIONS...

Страница 14: ...Page 11 85000 90 APPENDIX A WIRING CONNECTIONS...

Страница 15: ...Page 12 85000 90 APPENDIX A WIRING CONNECTIONS...

Страница 16: ...TION U V U WIND FROM EAST V WIND FROM NORTH EXAMPLE WIND AT 45 OPTIONAL 85052 BIRD WIRE ASSY WHEN PROPERLY ALIGNED JUNCTION BOX FACES SOUTH INSTALL VERTICALLY AS SHOWN TO AVOID MOISTURE DAMAGE TO CIRC...

Отзывы: