32400-90(R)

SERIAL COMMANDS TABLE

Command

Description

Notes:

CMD100

OPERATE

Places unit in continuous or polled operation

CMD110

PAUSE

Interrupts/pauses operation

CMD200 n

DAMPING (0=NONE, 1=FAST, 2=SLOW)

Determines compass measurement averaging (32500 Only)

CMD210 n

FORMAT:

0 ASCII

1 POLLED ASCII

2 NMEA (KTS, DIR)

3 NMEA (KTS, DIR, TEMP, RH, BARO)

4 RMYT

5 PRECIP

6 PRECIP POLLED

7 ASCII 2

9 DIAGNOSTIC

Determines serial output format. 

See section 3.1 for more detailed information. 

PRECIP formats substitute tipping bucket precipitation counts for 

the VIN4 voltage measurement. 

ASCII 2 omits VIN measurement values from the output string

CMD220 n 

OUTPUT RATE (0=15Hz, 1=0.1Hz, 2=2Hz)

The rate at which serial data strings are sent.

CMD230 c 

POLL CHARACTER (0-9, A-Z)

Sets the unique, single alphanumeric character polling address

CMD240 nn 

BAUD RATE: 

12 = 1200, 48 = 4800, 96 = 9600, 

192 = 19200, 384 = 38400

Selects one of several preset baud rates. If you change baud rate 

while connected, your external device must also be changed in 

order to continue communicating with the 32400

CMD250 n 

INPUT TYPE (1 = PULSE/POT, 2 = VIN3/VIN4)

Determines wind speed & direction inputs to use for output 

calculation.  Type 2 requires 0 to 5000 mV = 0 to 100 m/s (VIN1) 

and 0 to 540 degrees (VIN2).  Type 2 typically used for 86000 family 

of 2D Ultrasonic Anemometers.

CMD260 nnnn

BARO RANGE LOW (hPa)

Sets barometer low range at 0.0VDC (0500 hPa default)

CMD270 nnnn

BARO RANGE HIGH (hPa)

Sets barometer high range at 5.0VDC (1100 hPa default)

CMD280 nnn

PROPELLER PITCH (mm/rev)

Sets sensor cup wheel/propeller pitch

 

03002: 750 mm/rev

 

04101/4106/05103/05106: 294 mm/rev (default)

 

05108: 500 mm/rev

 

05305: 307 mm/rev

CMD900 

REPORT PARAMETER SETTINGS

Returns list of current settings in unit

CMD910 

START COMPASS CALIBRATION

See section 3.1 (32500 only)

CMD920 

STOP COMPASS CALIBRATION

See section 3.1 (32500 only)

Alternative command to enter OPERATE mode

Places unit in continuous or polled operation

3xESC 

Alternative command to PAUSE

Interrupts/pauses operation

3xCNTL-S 

Alternative command to START calibration

See section 3.1 (32500 only)

3xCNTL-X 

Alternative command to STOP calibration

See section 3.1 (32500 only)

Содержание 32400 SERIAL INTERFACE

Страница 1: ...ICAL INSTRUMENTS INSTRUCTIONS R M YOUNG COMPANY 2801 AERO PARK DRIVE TRAVERSE CITY MICHIGAN 49686 USA TEL 231 946 3980 FAX 231 946 4772 WEB www youngusa com P N 32400 90 REV R073117 SERIAL INTERFACE M...

Страница 2: ...ies that jumper is installed 0 signifies that jumper is omitted See the SERIAL FORMAT DIAGRAM for more details A B C SERIAL OUTPUT FORMAT Baud Rate Output Rate 0 0 0 ASCII Ouput 9600 2Hz 0 0 1 Polled...

Страница 3: ...erial output format isASCII POLLED or PRECIP POLLED See the SERIAL FORMAT DIAGRAM the 32400 sends data only when it receives a serial polling command Mc where c is the unique address of the unit The d...

Страница 4: ...al device must also be changed in order to continue communicating with the 32400 CMD250 n INPUT TYPE 1 PULSE POT 2 VIN3 VIN4 Determines wind speed direction inputs to use for output calculation Type 2...

Страница 5: ...Page 4 32400 90 R SERIAL OUTPUT FORMATS MODEL 32400...

Страница 6: ...Page 5 32400 90 R WIRING DIAGRAM MODEL 32400 JUMPER CONFIGURATIONS POWER...

Страница 7: ...Page 6 32400 90 R SERIAL WIRING CONNECTION MODEL 32400...

Страница 8: ...Page 7 32400 90 R WIRING DIAGRAM Output to 06201 Wind Tracker or 06206 Marine Wind Tracker...

Страница 9: ...Page 8 32400 90 R WIRING DIAGRAM TYPICAL APPLICATION WIRING...

Страница 10: ...Page 9 32400 90 R WIRING DIAGRAM NMEA2 TYPICAL WIRING WHEN USING NMEA2 FORMAT SENSORS MUST BE CONNECTED AS SHOWN FOR PROPER DATA REPORTING...

Отзывы: