32400-90(R)
SERIAL COMMANDS TABLE
Command
Description
Notes:
CMD100
OPERATE
Places unit in continuous or polled operation
CMD110
PAUSE
Interrupts/pauses operation
CMD200 n
DAMPING (0=NONE, 1=FAST, 2=SLOW)
Determines compass measurement averaging (32500 Only)
CMD210 n
FORMAT:
0 ASCII
1 POLLED ASCII
2 NMEA (KTS, DIR)
3 NMEA (KTS, DIR, TEMP, RH, BARO)
4 RMYT
5 PRECIP
6 PRECIP POLLED
7 ASCII 2
9 DIAGNOSTIC
Determines serial output format.
See section 3.1 for more detailed information.
PRECIP formats substitute tipping bucket precipitation counts for
the VIN4 voltage measurement.
ASCII 2 omits VIN measurement values from the output string
CMD220 n
OUTPUT RATE (0=15Hz, 1=0.1Hz, 2=2Hz)
The rate at which serial data strings are sent.
CMD230 c
POLL CHARACTER (0-9, A-Z)
Sets the unique, single alphanumeric character polling address
CMD240 nn
BAUD RATE:
12 = 1200, 48 = 4800, 96 = 9600,
192 = 19200, 384 = 38400
Selects one of several preset baud rates. If you change baud rate
while connected, your external device must also be changed in
order to continue communicating with the 32400
CMD250 n
INPUT TYPE (1 = PULSE/POT, 2 = VIN3/VIN4)
Determines wind speed & direction inputs to use for output
calculation. Type 2 requires 0 to 5000 mV = 0 to 100 m/s (VIN1)
and 0 to 540 degrees (VIN2). Type 2 typically used for 86000 family
of 2D Ultrasonic Anemometers.
CMD260 nnnn
BARO RANGE LOW (hPa)
Sets barometer low range at 0.0VDC (0500 hPa default)
CMD270 nnnn
BARO RANGE HIGH (hPa)
Sets barometer high range at 5.0VDC (1100 hPa default)
CMD280 nnn
PROPELLER PITCH (mm/rev)
Sets sensor cup wheel/propeller pitch
03002: 750 mm/rev
04101/4106/05103/05106: 294 mm/rev (default)
05108: 500 mm/rev
05305: 307 mm/rev
CMD900
REPORT PARAMETER SETTINGS
Returns list of current settings in unit
CMD910
START COMPASS CALIBRATION
See section 3.1 (32500 only)
CMD920
STOP COMPASS CALIBRATION
See section 3.1 (32500 only)
X
Alternative command to enter OPERATE mode
Places unit in continuous or polled operation
3xESC
Alternative command to PAUSE
Interrupts/pauses operation
3xCNTL-S
Alternative command to START calibration
See section 3.1 (32500 only)
3xCNTL-X
Alternative command to STOP calibration
See section 3.1 (32500 only)
Содержание 32400 SERIAL INTERFACE
Страница 5: ...Page 4 32400 90 R SERIAL OUTPUT FORMATS MODEL 32400...
Страница 6: ...Page 5 32400 90 R WIRING DIAGRAM MODEL 32400 JUMPER CONFIGURATIONS POWER...
Страница 7: ...Page 6 32400 90 R SERIAL WIRING CONNECTION MODEL 32400...
Страница 8: ...Page 7 32400 90 R WIRING DIAGRAM Output to 06201 Wind Tracker or 06206 Marine Wind Tracker...
Страница 9: ...Page 8 32400 90 R WIRING DIAGRAM TYPICAL APPLICATION WIRING...