Young 32400 SERIAL INTERFACE Скачать руководство пользователя страница 2

Page 1

32400-90(R)

MODEL 32400

SERIAL INTERFACE

SERIAL INTERFACE SPECIFICATION SUMMARY

*

Wind Speed Input: 

 

Sensor Type: 

AC Frequency Generator

 

Sensitivity: 

50mV p-p at 10Hz

 

Range: 

0-2000 Hz

Wind Direction Input:

 

Sensor Type: 

Potentiometer

 

Range: 

0-5000mV = 0 to 355 degrees

 

Excitation: 

5000mV (limited to 5 mA)

Voltage Inputs (Auxiliary Sensor Inputs):

 Resolution: 

12-bit

 

VIN1 and VIN2 

0-1000mV 

 

VIN3 and VIN4 

0-5000mV

Voltage Outputs:

 

OUT1 

0-5000mV 

0-100 m/s wind speed

 

OUT2 

0-5000mV 

0-360° wind direction

Serial Output: 

Full duplex RS-232, 

 

Half duplex RS-485 (2 mS turnaround), 

Baud: 1200, 4800, 9600, 19.2K, & 

38.4K, 8 data, 1 stop, no parity

Operating Temp: 

-50°C to 50°C 

Power: 

11 to 30 VDC, 40 mA

Mounting: 

Stainless steel U-bolt mounting clamp 

fits vertical pipe 25-50 mm (Ø1-2 in)

 

(1 inch IPS (Ø1.34 inch actual)

Size:    

7.50” (19.0cm) H

 

 

3.00” (7.6cm) W

 

 

3.00” (7.6cm) D

*

Specifications subject to change

1.0 INTRODUCTION

The Model 32400 SERIAL INTERFACE measures wind speed and 

direction signals from YOUNG sensors and signals from four general 

purpose voltage inputs. The voltage inputs may be used with YOUNG 

temperature, humidity, barometric pressure, precipitation, or other 

sensors. One of the voltage inputs may also be used with a tipping 

bucket precipitation gauge.  These input signals are converted into 

scaled values and placed in a serial string, which is output at up to 

15 hertz.
The serial output is available in several serial data formats in either full 

duplex RS-232 or half-duplex RS-485 signals. Both continuous and 

polled serial outputs are available. When polled, up to 16 units can 

be networked together. For marine applications the 32400 produces 

standard NMEA serial output sentences. Calibrated voltage outputs 

for wind speed and direction are also provided when the 32400 is 

connected to a YOUNG wind sensor.

2.0 INSTALLATION

The 32400 is supplied in a weather-resistant enclosure that mounts 

with a stainless steel U-bolt that will fit a 25 to 50 mm (1-2 in.) diameter 

vertical pipe. Refer to the WIRING DIAGRAM for electrical connection 

details and jumper settings.

3.0 OPERATION

Operation begins automatically when power is applied.  Jumper 

settings configure the 32400 for common output formats as well as 

output type.  Input signal connections are dependent upon the serial 

output format.

3.1 JUMPER CONFIGURATIONS

W1 JUMPERS  A, B, and C, determine serial output format. Jumper 

configurations and associated output format are listed below: 

1 signifies that jumper is installed, 0 signifies that jumper is omitted. 

See the SERIAL FORMAT DIAGRAM for more details.

A B C

SERIAL OUTPUT FORMAT (Baud Rate, Output Rate)

0 0 0 ASCII Ouput (9600, 2Hz)

0 0 1 Polled ASCII (9600)

0 1 0 NMEA1 (4800, 2 Hz)

0 1 1 NMEA2 (4800, 2 Hz)

1 0 0 RMYT (9600, 15 Hz)

1 0 1 PRECIP (9600, 15 Hz)

1 1 0 PRECIP POLLED (9600)

1 1 1 SOFTWARE Mode (set by user, see section 4.2)

ASCII and POLLED ASCII are general purpose outputs that may 

be used with the YOUNG 26800 or devices that can communicate 

serially.  
NMEA1 and NMEA2 outputs are generally for marine applications. 

NMEA1 produces a “$WIMVW” string containing speed and direction 

values.NMEA2 produces both a “$WIMVW” and “$WIXDR” string, 

the latter containing temperature, humidity and pressure values.
RMYT is a binary format for use with the YOUNG Wind Tracker.

PRECIP and PRECIP POLLED configure VIN4 as a special input to 

count tipping bucket precipitation gauge switch closures. (Requires 

a 10K ohm resistor from VIN4 to EXC terminal.)
SOFTWARE mode allows output format and other parameters to 

be set using serial commands. Please see section 4.0 SERIAL 

COMMUNICATION and the SERIAL FORMAT DIAGRAM for more 

information.
W2 & W3 JUMPERS determine output connection type. Only one 

connection type may be used at a time. Please refer to the WIRING 

DIAGRAM for jumper location and connection details.

JUMPERS

OUTPUT TYPE

VOUT

Calibrated output for wind speed and direction 

OUT1  0-5000mV = 0-100 m/s Wind Speed 

OUT2  0-5000mV = 0-360 degrees Wind Direction

232

RS-232 full duplex serial

485

RS-485 half duplex serial

3.2 SIGNAL INPUTS

The 32400 has two special inputs for wind speed and direction from 

YOUNG wind sensors and four voltage input channels for connection 

to temperature, humidity, barometric pressure, precipitation, or other 

sensors. For best performance, sensors should be installed within 

3m (10ft.) of the 32400.

Measurements from the voltage input channels are converted to 

numerical values (0-4000) when ASCII, POLLED ASCII, PRECIP, 

or PRECIP POLLED are used.  VIN1 and VIN2 full scale input is 

1000mV DC (serial value = input mV x 4); VIN3 and VIN4 full scale 

input is 5000mV (serial value = input mV x 0.8).  Note that VIN4 is 

used to count tipping bucket precipitation sensor tips when PRECIP 

or PRECIP POLLED are used.
When NMEA1 or NMEA2 are used the measurements from the 

voltage input channels are converted to following: 

VIN1 (0 to 1000mV must = -50 to +50 C),Temperature (C); 

VIN2 (0 to 1000mV must = 0 to 100%), Humidity (%); 

VIN3, Barometric Pressure (hPa); 

VIN4, not used.  [Wind speed, (Knots)]

Please refer to SERIAL FORMAT DIAGRAM and WIRING DIAGRAM 

in the back of this manual for additional details.

Содержание 32400 SERIAL INTERFACE

Страница 1: ...ICAL INSTRUMENTS INSTRUCTIONS R M YOUNG COMPANY 2801 AERO PARK DRIVE TRAVERSE CITY MICHIGAN 49686 USA TEL 231 946 3980 FAX 231 946 4772 WEB www youngusa com P N 32400 90 REV R073117 SERIAL INTERFACE M...

Страница 2: ...ies that jumper is installed 0 signifies that jumper is omitted See the SERIAL FORMAT DIAGRAM for more details A B C SERIAL OUTPUT FORMAT Baud Rate Output Rate 0 0 0 ASCII Ouput 9600 2Hz 0 0 1 Polled...

Страница 3: ...erial output format isASCII POLLED or PRECIP POLLED See the SERIAL FORMAT DIAGRAM the 32400 sends data only when it receives a serial polling command Mc where c is the unique address of the unit The d...

Страница 4: ...al device must also be changed in order to continue communicating with the 32400 CMD250 n INPUT TYPE 1 PULSE POT 2 VIN3 VIN4 Determines wind speed direction inputs to use for output calculation Type 2...

Страница 5: ...Page 4 32400 90 R SERIAL OUTPUT FORMATS MODEL 32400...

Страница 6: ...Page 5 32400 90 R WIRING DIAGRAM MODEL 32400 JUMPER CONFIGURATIONS POWER...

Страница 7: ...Page 6 32400 90 R SERIAL WIRING CONNECTION MODEL 32400...

Страница 8: ...Page 7 32400 90 R WIRING DIAGRAM Output to 06201 Wind Tracker or 06206 Marine Wind Tracker...

Страница 9: ...Page 8 32400 90 R WIRING DIAGRAM TYPICAL APPLICATION WIRING...

Страница 10: ...Page 9 32400 90 R WIRING DIAGRAM NMEA2 TYPICAL WIRING WHEN USING NMEA2 FORMAT SENSORS MUST BE CONNECTED AS SHOWN FOR PROPER DATA REPORTING...

Отзывы: