A. Lid

B. Mist exit port

C. Metal mesh cover

D. Remote control receiver

E. Purple clay base

F. Ventilation hole switch

G. Air pipe

H. Red water fill line 

I.  Water level sensor

J. Ultrasonic plate

K. Ionizer on light 

L. Ion release port 

M. Anti-slip pads 

N. Air intake

O. Power adaptor input

P. Remote control

P

3

Diagram

Содержание Rainstone

Страница 1: ...Rainstone Diffuser OPERATION MANUAL ...

Страница 2: ...neration for more than 1 000 years Young Living s Rainstone has a robust feature set including continuous ultrasonic diffusion at 1 7 million waves per second 1 2 3 6 and 8 hour settings with automatic shutoff five soft LED light settings blue yellow purple alternating each color and off a negative ionizer and a remote control The Rainstone s elegant design and handcrafted artistry make it an exqu...

Страница 3: ...control receiver E Purple clay base F Ventilation hole switch G Air pipe H Red water fill line I Water level sensor J Ultrasonic plate K Ionizer on light L Ion release port M Anti slip pads N Air intake O Power adaptor input P Remote control P 3 Diagram ...

Страница 4: ...low and purple and the ionizer with automatic shut off after 8 hours default setting 1H Press for 1 hour of continuous diffusion with automatic shut off 2H Press for 2 hours of continuous diffusion with automatic shut off 3H Press for 3 hours of continuous diffusion with automatic shut off 6H Press for 6 hours of continuous diffusion with automatic shut off MIST ON OFF Turns on or off the mist dif...

Страница 5: ...ating blue yellow and purple changing every 2 30 minutes Installing the Remote Control Battery Put the included battery in the battery groove with facing upward then put the battery cover back on and twist right to fasten the cover Operating Instructions 1 Fill the included water cup with room temperature tap or mineral water Do not use purified or distilled water or the diffuser may not generate ...

Страница 6: ... the diffuser may not generate mist 6 Push the ventilation hole switch down to open it 7 Place the lid back on the diffuser 8 Plug the power line plug into the power adaptor input on the diffuser base 9 Plug the adaptor plug into a power socket 10 Press the remote control ON OFF 8H button to turn on the diffuser LED light alternating blue yellow and purple and the ionizer with automatic shut off a...

Страница 7: ...n the diffuser and store dry Replacement ultrasonic plates can be purchased from Young Living Cleaning the Interior of the Diffuser 1 Take the lid off of the diffuser 2 Pull the ventilation hole switch upward to close it 3 To empty the water reservoir pour out the water from the side opposite the ventilation hole Note Avoid getting any water into the ventilation hole or it will damage the internal...

Страница 8: ...al cleanser to clean the exterior of the water reservoir Note Do not get water or cleanser on the remote control receiver 5 Replace the metal mesh cover Align the mesh cover groove with the remote control panel and twist to the right until you hear a click Verify that it is locked in place Specifications Product Rainstone Diffuser Item No 5331 Dimensions 5 x 5 x 6 69 in 128 x 128 x 170 mm Material...

Страница 9: ...e Room temperature tap or mineral water Do not use purified or distilled water Usage Environment Indoor Safety and Care Instructions Please read and follow these safety guidelines closely to ensure safe operation of the diffuser Unplug the diffuser immediately and discontinue use in the event of smoke or a burning smell Use room temperature tap or mineral water Do not use distilled or purified wat...

Страница 10: ...r does not qualify for replacement by Young Living Do not use metal objects to clean the ultrasonic plate use only a cotton swab or cloth dipped in rubbing alcohol or a neutral detergent Never use the product for purposes other than those listed in this manual If the unit will not be used for an extended period or needs to be relocated unplug the power adaptor empty the water reservoir and wipe th...

Страница 11: ...illed water Check the water reservoir level to see if it is empty or above the red water fill line Check whether the power adaptor is securely plugged into the wall socket and the rear of the diffuser Verify that power outlet is working try another outlet Verify that ventilation hole is open Check for essential oil buildup on the ultrasonic plate If oil buildup is present read the cleaning instruc...

Страница 12: ...istributor 4 Defects or damage from use of materials other than essential oils 5 Defects or damage from improper testing operation maintenance installation adjustment or any alteration or modification of any kind 6 Breakage or damage caused by use of other than the specified voltage 7 Products disassembled or repaired by anyone other than a Young Living Essential Oils authorized agent so as to adv...

Страница 13: ...d back to YLEO the buyer will need to send the product back in its original box if available with the power adaptor a copy of the original purchase receipt and the YLEO Return Merchandise Authorization RMA displayed clearly on the receipt which will be provided by Member Services U S Shipping Young Living Essential Oils Returns RMA ______ 142 East 3450 North Spanish Fork UT 84660 For all other mar...