DDS Calibration

This operation wil reset the 20 frequency memories to their original default values and allow 
calibration of the DDS frequency.

Turn off power.  Simultaneously press V/M/SAV and RIT/MOD, turn on power, and hold down the 
two keys until the display appears as shown below then release the keys.

After a few seconds, the HB-1A will enter the DDS calibration mod and the display will appear as 
below.

With a frequency counter connectedto the DDS test point, turn the Tuning knob until the counter 
reads the same as the HB-1A display.  Press RIT/MOD to exit, then V/M/SAV to finish.

Voltmeter Calibration and Sidetone Adjustment 

Adjust VR1 so that the voltage displayed is the same as that measured with an accurate external 
voltmeter.

Adjust VC to set the sidetone frequency to 700 Hz.

Содержание HB-1A MK2

Страница 1: ...y an internal Lithium Ion battery or an external power source The LCD display shows the following Frequency Operating Mode Supply Voltage Signal strength Receiver Incremental Tuning RIT Forward and Re...

Страница 2: ...on the back of the HB1A Install the battery pack and connect to the circuit board Carefully locate the battery pack so the back cover can be replaced and secure battery with the adhesive strips Import...

Страница 3: ...on Pressing this key will alternate between Memory mode MEM and VFO mode The display will show MEM or VFO represents the numbers 01 20 In Memory mode the Tuning knob is used to change memory locations...

Страница 4: ...e received frequence is the same as the transmit frequency zero offset Turnng the Tuning knob clockwise raises the received frequency as indicated by the up arrow Turning the Tuning knob counter clock...

Страница 5: ...in for two seconds to exit Exit will automatically occur if no operations happen for 8 seconds Changing the Frequency Tuning Steps Pressing the Tuning knob will change the tuning step In the amateur b...

Страница 6: ...s press the DOT paddle to increase the keyer speed or the DASH to decrease When complete press CQ SET briefly to exit The letter E will be heard Entering Your Callsign Press and hold CQ SET until the...

Страница 7: ...g When complete press CQ SET briefly to exit Transmitting When transmitting within the amateur bands the display will show the approximate power output The letter S is replaced with F followed by a se...

Страница 8: ...se the keys After a few seconds the HB 1A will enter the DDS calibration mod and the display will appear as below With a frequency counter connectedto the DDS test point turn the Tuning knob until the...

Отзывы: