Trouble Code
Code
Causes
Resolutions
E01
Poor communication
between electronic
meter and controller
1. Check that the connection between the electronic meter
and the controller is not properly connected.
2. The main IC of the controller contacts badly and is
re-tightened.
3. Controller power supply abnormal, change controller
E02
Explosion-proof and
impact-proof
protection
1.If the motor is open or in bad contact, replace the motor or
check the connecting terminals.
2.Power tube breakdown, replace it or the controller.
E05
Over current
protection
1.Overload.
2.The resistance of the treadmill is too heavy and needs to be
lubricated.
3.The motor is damaged, replace it.
E06
Overload protection
E10
Keyboard and panel
control connection
communication
failure
1. Check if the connection between the electronic watch and
the controller is poorly connected.
2. The controller plug is not in good contact and is re-inserted.
3. The controller power supply is abnormal and the controller
is replaced.