background image

EPDT

055a

 

-  5  -

 

5.

 

Installation and operation 

5.1 Precautions for installation 

 

 Caution 

(1)  The  noiseless  heater  should  be  mounted  300mm  or  more  from  the  tank’s  walls  and 

bottom. (Refer to 5.2 Example of piping) 

* Vibration may occur in a tank by the flow of a liquid. 

(2) Use it within the maximum warning sound temperature limit. 

* Vibration in a tank and piping occurs. 

(1) In order to obtain a result as planned, please fully utilize the nominal size selection 

chart. 

(2) There are various methods in attachment and please take into consideration the 

blow-off position with the size of a tank etc. (Refer to 5.2 Example of iping) 

(3) VB-7 vacuum relief valve is recommended in the piping in order to prevent a back-

flow condition when the steam is stopped. 

 

5.2 Example of piping 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

5.3. Precautions for operation 

 

 Warning 

(1) Do not touch the product by bare hands 

* Failure to follow this notice may cause burn or injury. 

(2) Submerge the product in the tank. 

* Steam may spout out and result in burns. 

 
 