23
■EPDT-179c■
Presumable cause III.18: Hexagon head bolt
○
○
○
○
28
28
28
28
on top diaphragm case becomes loose.
Action (41) : Retighten hexagon head bolt
○
28
of top diaphragm case.
Presumable cause III.19: Hexagon socket head cap bolt
○
○
○
○
26
26
26
26
and locknut
○
○
○
○
25
25
25
25
are
loosened.
Action (42) : Follow steps described in Actions (7) to (11) and then perform Actions (20) to (23).
Presumable cause III.20: Diaphragm
○
○
○
○
22
22
22
22
is damaged.
Action (43) : Follow steps described in Actions (7) to (12); replace diaphragm
○
22
.
After replacement,
perform steps in Actions (19) to (23).
Presumable cause III.21: Hexagon socket head cap bolt
⑥
⑥
⑥
⑥
on the bottom diaphragm
case is loosened or O-rings
③
③
③
③
and
④
④
④
④
are damaged
Action (44) : In case of loosened bolt: follow steps described in Actions (7) to (12). Retighten the
hexagon head bolt
⑥
. And then perform steps in Actions (19) to (23).
Action (45) : In the case O-ring is damaged, follow steps described in Actions (7) to (12). Unscrew
hexagon head bolt
⑥