■EPDT-179c■
Action (5) : Clean the needle valve and hole of lower diaphragm casing.
Action (6) : Turn the needle valve to full close and then open by turning one turn in reverse direction with
a flat head screwdriver.
Presumable cause I.4: Foreign object is pinched between valve disc and valve seat; or
these parts are damaged.
Action (7) : Remove the cap
○
35
.
Action (8) : Loosen locknut
○
33
.
Loosen bifacial
adjusting screw
○
34
by turning it CCW
to relieve the spring load.
Action (9) : Unscrew 6 hexagon head bolts
○
32
. Remove spring chamber
○
32
, spring plate
○
30
and
spring
○
29
.
→
→
→
→
Action (10) : Loosen 12 hexagon head bolts
○
40
and remove top diaphragm case
○
27
.
Note: Remove top diaphragm case
○
○
○
○
22227777
in close relation to diaphragm
○
○
○
○
22
22
22
22
.
.
.
.
(Do not attempt to twist casing any further. This may damage balance diaphragm