7. Operating Procedure 
  7.1  Warning and precaution on operation 

 

Warning

 

( 1 )  Do not touch directly to pressure reducing valve with bare hands after flowing hot fluids 

*Doing so may result in burns.   

( 2 ) Before flow the hot fluids in the pipe line, make sure that the fluids will not cause the 

risks through the end of piping system and the pipes are connected tightly.       
*In case hot fluids blows out, it may result in burns. 

 

Caution

 

( 1 )  When opening the by-pass stop valve, ensure that the reduced pressure will not exceed 

set pressure of safety relief valve.    

*In case reduced pressure exceeds set pressure of safety relief valve, the safety relief 

valve operates and blows out the fluids.       

( 2 ) When operation is discontinued for a long period of time, completely purge fluid from 

pressure reducing valve and piping system, and close the stop valve located up stream 
and down stream of pressure reducing valve. 

*Water scales developed in the piping may cause erratic operation of pressure reducing 

valve.

 

 
 7.2 Adjustment Procedure 

GD-24/24B pressure reducing valve is set at 0.1MPa at the factory. Change the set pressure as 

appropriate.  
Wrong or poor adjustment may cause hunting, scale buildup or water hammer, or severely 

damage relevant parts. Be sure to follow the following steps to complete proper adjustment. 

(Refer to the parts number in “3.2 Construction”). 

 

1) Close the stop valves at both sides of the pressure reducing valve, and thoroughly purge the 

 system through the by-pass line, with the by-pass valve opening adjusted so that the safety 
 relief valve is not activated. When completed, be sure to close the by-pass valve. 

2) Slowly open the inlet stop valve, then open the outlet stop valve slightly, allowing a trickle 

 to be discharged. 

3) Loosen the lock nut(12), and slowly turn the adjusting screw(11) (clockwise to increase, 

 counterclockwise to reduce) while observing the outlet side pressure gauge.   

4) Slowly open the outlet stop valve to its full-open position. 
5) After the adjustment, tighten the lock nut(12). 

 

 
8. Maintenance Procedure 

Be aware of foreign materials because many of faults on pressure reducing valve are due to the 

existence of foreign materials. Please be reminded that our warranty does not cover damages 
caused by foreign materials at the customer site. Failure resulting from faulty pressure gauge, 

clogged strainer and leakage from by-pass stop valve are phenomena kindred to failure of pressure 

reducing valve. Clogged strainer will decrease the secondary pressure and leakage from by-pass 
pipe will increase the secondary pressure. Before do the troubleshooting of pressure reducing valve, 

check such symptom of the strainer and stop valve.       

 

Содержание GD-24

Страница 1: ...lease carefully store this manual in a handy place The following safety symbols are used in this manual Warning Caution Contents 1 Features 1 2 Specifications 1 3 Dimensions and Construction 3 1 Dimen...

Страница 2: ...rusty water problems 3 A stainless steel valve seat reduces wear and increases durability 4 A sealed construction prevents external leakage even if the diaphragm should break 5 The valve can be mount...

Страница 3: ...3 1 Dimensions Weight GD 24 24B mm Nominal size d L H H1 Weight kg 15A Rc 1 2 80 193 41 5 1 8 20A Rc 3 4 90 210 45 2 4 25A Rc 1 100 230 50 3 3 32A Rc 1 1 4 120 265 60 4 7 40A Rc 1 1 2 150 315 62 8 2 5...

Страница 4: ...ing 22 Plug 27 Label 28 Spring Washer 4 Operation Refer to the parts number in 3 2 Construction Turning the adjusting screw 11 to compress the adjusting spring 17 and the load of adjusting spring is i...

Страница 5: ...he pipe is ideal Cv Value Nominal size 15A 20A 25A 32A 40A 50A Cv value 1 5 1 9 3 4 7 10 Calculation formula for Cv value P G V Cv 365 0 P1 Inlet pressure MPa A V Rated flow rate m3 h P2 Reduced press...

Страница 6: ...5 EPDT 209 5 2 Flow Rate Characteristics Chart 5 3 Pressure Characteristics Chart...

Страница 7: ...lenoid valve secure at least 3 m from the valve Failure to do so may result in malfunction or drastically shortened service life 7 When pressure reducing in two stages secure at least 3 m between the...

Страница 8: ...nt parts Be sure to follow the following steps to complete proper adjustment Refer to the parts number in 3 2 Construction 1 Close the stop valves at both sides of the pressure reducing valve and thor...

Страница 9: ...and after pressure reducing valve and remove all foreign matter and scales via the by pass line before operation Failure to do so may cause the malfunction of pressure reducing valve Consumable parts...

Страница 10: ...oxes are consumable parts Nut Spring Lock Washer Diaphragm Shell Diaphragm Suspension Metal Pressure Gauge Body Valve Seat Set Screw Washer Disc Valve O ring Spring Cap Adjusting Screw Sealed Nut Bolt...

Отзывы: