![Yoshitake GD-24 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/yoshitake/gd-24/gd-24_installation-and-operation-manual_3565924004.webp)
-3-
■
EPDT-209
■
3.2 Construction
No.
Name of parts
1 Body
2 Spring
Chamber
3 Cap
4 Valve
5 Valve
Seat
6 Disc
7 Suspension
Metal
8 Diaphragm
Shell
9 Diaphragm
10
Spring Plate
11
Adjusting Screw
12
Lock Nut
13
Washer
14
Set Screw
15
Spring Lock Washer
16
Nut
17
Adjusting Spring
18
O-ring
19
Bolt
20
Sealed Nut
21
Spring
22
Plug
27
Label
28
Spring Washer
4. Operation
(Refer to the parts number in “3.2 Construction”)
Turning the adjusting screw(11) to compress the adjusting spring(17) and the load of adjusting
spring is introduced to the diaphragm(9) and suspension metal(7) to open the valve(4). Then,
the fluids begin to flow from the inlet side through the upper side of the valve. The reduced
pressure is led to the diaphragm to be balanced with the adjusting spring load, and control the
valve travel to maintain the reduced pressure.