YO People Counter
User guide
v1.0
page 23/35
DEVICE PARAMETERS
NAME
DESCRIPTION
POSSIBLE
VALUES
DEFAULT
VALUE
READ/
WRITE
measinterval
Measuring and sending interval
LoRa [s]
1–999999 [s]
28800 [s]
R/W
clearsumtime
Clearing the sum of people
counters detection. Setting
value to 0 equals to disable
refreshing counters.
0-1440 [min]
120 [min]
R/W
DETECTION AREA PARAMETERS
NAME
DESCRIPTION
POSSIBLE
VALUES
DEFAULT
VALUE
READ/
WRITE
radarfreq
Frequency channel of the radar
sensor
Low, middle,
high
low
R/W
holdtime
Time between measurements.
It is counted after the radar
loses the object from its field of
view
1-7200 [s]
1 [s]
R/W
sensitivity
The sensitivity of the device
sensor in [dB]. The highest is
10; 60 is the lowest
10-60 [dB]
30 [dB]
R/W
beamanglemin
The minimum beam angle of the
sensor. The parameter
describes the field of view of
the device
-90
॰
÷ 90
॰
-30
॰
R/W
beamanglemax
The maximum beam angle of
the sensor. The parameter
describes the field of view of
the device
-90
॰
÷ 90
॰
30
॰
R/W
beamanglethreshold
The beam angle threshold for
the object approaching or
moving away from the sensor
-90
॰
÷ 90
॰
0
॰
R/W
distancerange
Setting maximum distance
range of sensor
5m, 10 m,
30m, 100m
10 m
R/W
distancemin
Minimum distance detection
field based on the percentage
0-100[%]
0 [%]
R/W