DEVICE PARAMETERS
NAME
DESCRIPTION
POSSIBLE
VALUES
DEFAULT
VALUE
READ/
WRITE
measinterval
Measuring and sending interval
LoRa [s]
1–999999
300
R/W
measthreshold
Measuring and sending threshold
accuracy
1-9999
20
R/W
chxfunc
Number of channels with function of
measurement current or voltage
0-20 mA
0-10 V
0-20 mA
R/W
Parameters description
-
nwktype:
used for setting the device in public or private network type.
-
acttype:
used for setting the device in ABP or OTAA mode.
-
deveui, … , appskey:
predefined addresses and keys, these parameters are generated using
multiple IDs specific to the particular MCU and are unique for each device.; they can be
changed if needed.
-
interval:
determines the interval of sending broadcast packets, used to connect to every BLE
receiver around the device.
-
subband:
used for setting the communication frequency sub-band in LoRaWAN.
-
measinterval:
measurement interval [s] between sending LoRa packets.
-
measthreshold:
measurement threshold for each channel. If current or voltage value
between previous measurement and the next differs by a value of ‘meastreshold’, it queues
this data for sending. Measurement difference is reported in subsequent LoRa packets along
with measurement time.
-
ch1func…ch6func:
numbers of channels with measurement of current or voltage flow in the
network connected to the device.