1
)
Before
soldering
,
remove
ceramic
cartridge
&
pressure
balanced
valve
(
1
,
2
,
3
,
4
,
5
,
6
)
remove
integral
(
7
,
8
,
9
,
10
,
11
,
12
,
13
,)
from
shower
body
.
2
)
After
cool
down
from
soldering
,
replace
Integal
(
7
,
8
,
9
,
10
,
11
,
12
,
13
)
in
order
back
to
shower
body
,
use
flat
head
screwdriver
to
turn
the
Studs
(
9
)
to
"
Close
"
position
,
install pressure balanced valve and ceramic cartridge, turn on water supplies, check
connection
for
leak
,
turn
Studs
(
9
)
slowly
to
"
Semi
On
"
position
,
flush
the
system
with
both
hot
and
cold
water
for
1
minute
.
Turn
off
water
supplies
,
turn
Studs
(
9
)
to
"
full
open
"
position
,
3
)
Replace
pressure
balanced
valve
and
ceramic
cartridge
in
order
back
to
shower
body
,
make
sure
silicon
seals
(
A
)
are
on
the
right
position
,
installed
without
silicon
seals
may
cause
leakage
.
Installation
When
connect
with
"
CxM
Adapter
or
CxF
Adapter
,
wrap
the
threads
with
right
amount
of
Teflon
Tape
.(
Wrap
20cycles
)
Note
:
connected
without
Teflon
Tape
may
cause
leakage
.
Im p ort a nt N otes:
Before
reinstall
the
Ceramic
cartridge
make
sure
temperature
ring
(
E
)
is
on
the
factory
temperature
preset
position
.
Soldering
without
removing
ceramic
cartridge
,
pressure
balanced
valve
and
integral
stop
will
void
the
factory
warranty
.
* Do not insert the screens
washer into the inlet
4"
1
/
2
"
1
)
Connect
spout
and
shower
unit
,
Put
a
1
/
2
"
spout
if
there
is
no
connection
to
either
one
.
Attach
shower
head
only
after
flushing
the
system
with
both
hot
and
cold
for
1
minute
.
2
)
After
all
connection
has
been
made
.
Attach
handle
and
test
system
.
Check
all
connection
and
valve
for
any
leaks
.
3
)
Test
water
pressure
on
full
hot
and
cold
.
If
water
pressure
is
unbalanced
,
use
the
stud
on
the
valve
to
adjust
.
M o d e ls:YP5745T S , S e r i e s
1
)
Remove
handle
and
attach
faceplate
with
supplied
screws
.
2
)
Attach
handle
and
fasten
,
test
system
again
.
1
2
3
4
5
6
7
8
9
10
11
12
13
IPS
SWEAT
1
2
3
4
5
6
7
8
9
10
11
12
13
Pressure
Balance
Valve
Application
APPLICATION
A
pressure
balance
valve
was
designed
to
be
adjusted
incoming
hot
or
cold
water
pressure
and
compensates
for
fluctuations
to
keep
shower
temperatures
constant
and
comfortable
.
When
the
inlet
hot
water
is
120°F
-
180°F and
inlet
cold water is
39°F
to
84°F
.
The
balance
valve
can
compensate
the
temperature
of
outlet
water
from
normal
to
106°F
and
there
is
a
component
that
can
limit
the
hottest
position
setting
.
Tub
/
shower
faucets
have
this
pressure
balancing
feature
to
prevent
shower
shock
.
FEATURES
:
1
.
passed
the
certificate
of
anti
-
scaled
standard
ASSE
1016
and
Ans
/
ASME
A112
.
18
.
1M
U
.
S
.
A
.
And
CSA
2
.
Our
balance
valve
have
applied
the
patent
of
USA
,
China
and
Taiwan
.
The
other
countries
patent
are
pending
.
3
.
The
balance
valve
are
component
of #303
stainless
steel
.
precise
ceramic
and
high
tech
plastic
material
.
Therefore
the
parallel
and
concentricity
keep
well
.
Easy
to
installation
,
operation
smoothly
and
quality
stability
.
4
.
Temperature
limit
setting
our
pressure
balance
valve
can
be
adjusted
via
a
component
to
the
temperature
limit
setting
.
So
that
the
discharge
temperature
will
not
exceed
120°F
.
5
.
When
the
inlet
water
pressure
change
up
to
50% or
cold
water
pressure
raise
up
to 50%,the
temperature
of
outlet
still
can
maintain
within
± 35.2°F
to
ensure
shower
safety
to
prevert
hot
burn
.
6
.
When
the
temperature
of
outlet
water
is
100°F
±2°F, outlet
cold
water
flow
rate
decrease
,
the
outlet
water
still
can
be
adjusted
within
120°F
in
2
second
.
In
other
words
,
the
oulet
hot
water
can
be
decreased
flow
rate
to
1
.
9L
/
min(1
.
5GPM)to
free
from
hot
burn
.
7
.
The
pressure
balance
valve
we
designed
can
be
said
as
two
in
one
valve
for
installation
eigther
in
the
front
side
or
in
the
oppostite
direction
of
the
same
wall
and
the
same
water
suppley
pipes
.
NOTE
:
1
.
Make
sure
the
proper
position
of
hot
/
cold
water
supply
pipes
before
install
the
valve
2
.
The
torque
suggest
condition
:
100
-
120
kgf
.
com
(
for
mode
)
3
.
The
hot
/
cold
water
supply
condition
hot
water
supply
120°F-180°F
cold
water
supply
39°F-85°F
4
.
When
finish
assembly
,
make
sure
it
is
cold
water
,
warm
water
,
hot
water
incoming
when
you
turm
on
the
faucet
.
5
.
If
the
water
contains
contaminants
a
lot
,
it
'
s
required
in
a
per
i
od
and
check
the
valve
to
ensure
functionally
normal
and
working
properly
,
The
inspection
times
depend
on
the
amount
of
contaminants
in
the
water
.
6
.
The
valve
must
be
set
by
professional
installer
to
ensure
sefety
,
Any
in
-
proper
installation
will
raise
the
discharge
temperature
and
may
get
hot
burns
.
YP5745TS
Insert the
screens washer
Hot Position
Cold Position
Warm Position
66
"
Floor level
M
in
2
4
"
DOWN
UP
hot
cold
4"
Open
Close
2"
1/
2-
14