Synergy SA102 Powered Speaker

Thank you for choosing Yorkville’s Synergy SA102 arrayable speaker, the pinnacle of clarity and output in a 

fully expandable speaker system. The SA102 excels in sound reinforcement applications where a line array is 

desired but cannot be easily accommodated. Used alone or in multiples with the matching SA115 subwoofers, 

the SA102 is designed to deliver reliable, high quality audio at a professional level.

Cabinet Features

The SA102 is constructed of high strength multiply birch plywood for ultimate durability. At the heart of the 

SA102 is a Paraline lens loaded with a coaxial compression driver along with a 10-inch woofer mounted on a 

30°H x 45°V constant directivity horn. Paraline technology was first developed for Yorkville’s flagship VTC Pro 

Audio Elevation series line array. By channeling the sound waves along equidistant paths, the Paraline lens 

converts the point source compression driver into a line source with constant phase and amplitude. The result 

is a completely balanced sound field and coverage pattern across the cabinet’s horizontal and vertical planes.

The unique design of the SA102 allows the cabinets to be placed side by side without interference. 

Cabinets can be placed together to cover as wide a pattern as desired, including 360 degrees, without 

any lobbing or interference patterns. 

Electronic Features 

Innovative DSP processing is used to drive the 900-watt Class-D woofer amplifier and the three-tier 300-watt horn 

amplifier. An active crossover for the amplifiers ensures that the woofer and horn operate optimally; meanwhile, 

separate non-defeatable limiters protect those drivers from excessive peaks and over-powering. The drivers 

themselves are sourced from the world’s premier manufacturers offering an extended lifetime of smooth, powerful 

performance. We are confident you will find the SA102 a worthy mainstay for all of your sound application needs. 

1. Power Switch and Indicator 

The green power LED illuminates when the power switch is turned to the On position and AC voltage is supplied.

2. PowerCON TRUE AC Loop Thru 

As a standard, the AC inlet on the SA102 accepts locking PowerCON TRUE power cords. There is also an AC 

outlet that can be used to loop power through to other cabinets in your array using a male to female PowerCON 

TRUE looping power cord. Check with your local Yorkville dealer for availability of these accessory cords.

IMPORTANT: DO NOT EXCEED THE CURRENT RATING OF THE POWER and ACCESSORY CORDS. 

PLEASE READ THE SECTION OF THIS MANUAL CALLED CASCADE INSTALLATION 

3. Input Jack 

This female-XLR accepts line level XLR microphone cables. For best noise reduction use balanced sources.

4. Dual Link Outputs

These XLR male connectors can be used with a standard XLR cable to daisy-chain up to 20 SA102 or SA115 

cabinets without signal degradation. Simply loop from one cabinet’s Link jack to the next cabinets Input jack.

5. SA102 Level Control

This control adjusts the volume level of the SA102 relative to the input signal level. Mixers and other audio sources 

connected to the SA102 tend to have different output voltages, which mean the level control on the SA102 is used 

to fine tune the cabinet’s volume relative to the mixer settings. It is perfectly acceptable to set the SA102 Level 

above or below the center 0 dB setting. When arraying multiple cabinets, it may be desirable to reduce the volume 

of some cabinets to better cover the audience. (ex. The outer box of a cluster may be against a wall)

6. Mode Switch (Sub/No Sub) 

This switch allows the user to configure the SA102 to be used with or without a subwoofer. In “No Sub” mode, 

the cabinet’s internal high-pass (low-cut) filter is set to 50 Hz. When using the SA102 with a subwoofer, such as 

the SA115, depress the button to set the internal high-pass filter to align perfectly with the subwoofer.

7. HF (High Frequency) Adjust Selector 

The HF Adjust switch is used to set the relative high frequency level of the SA102. If you are assembling multiple SA102 

cabinets into an array, you may notice an increase in bass and a lack of treble. This is due to low frequency coupling between 

the cabinets of the low frequency drivers. Setting this control to the number of cabinets in the array will insure flat response 

from the system. As the number of cabinets increases the high frequency output will be correspondingly increased. 

The HF switch can also be used in applications where the loudspeakers are situated far from the audience. 

The increase of treble will help overcome the natural loss of high frequency due to traveling a greater distance.

Содержание Synergy SA102

Страница 1: ...OWNER S MANUAL MANUEL DE L UTILISATEUR SA102 SA102 ...

Страница 2: ...a chaleur Les dispositifs marqués d une symbole d éclair sont des parties dangereuses au toucher et que les câblages extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés par un opérateur formé ou en utilisant des cordons déjà préparés Cordon d Alimentation Ne pas enlever le dispositif de sécurité sur la prise polarisée ou la prise avec tige de mise à la masse du ...

Страница 3: ...This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Cet équipement a été testé ...

Страница 4: ... PowerCON TRUE power cords There is also an AC outlet that can be used to loop power through to other cabinets in your array using a male to female PowerCON TRUE looping power cord Check with your local Yorkville dealer for availability of these accessory cords IMPORTANT DO NOT EXCEED THE CURRENT RATING OF THE POWER and ACCESSORY CORDS PLEASE READ THE SECTION OF THIS MANUAL CALLED CASCADE INSTALLA...

Страница 5: ...es that a level has been reached where the SA102 limiters are reducing the signal internally to prevent damage or distortion It also indicates that further increases in input level or increasing the SA102 Level control position will not appreciably increase acoustic output The red Clip LED indicates that the input level is ex cessive and further increases in level will cause severe distortion This...

Страница 6: ...surpuissance Les haut parleurs eux mêmes proviennent des meilleurs fabricants au monde ce qui garantit une durée de vie pro longée et des performances constantes et puissantes Nous sommes convaincus que le SA102 sera un outil de choix pour tous vos besoins en matière d applications sonores 1 Interrupteur et Indicateur d Alimentation Le voyant vert d alimentation s allume lorsque l interrupteur d a...

Страница 7: ...ut également être utilisé dans les applications où les haut parleurs sont situés loin du public L augmentation des aigus aidera à surmonter la perte naturelle des hautes fréquences due au déplacement sur une plus grande distance 8 Indicateurs Clip et Limit Les indicateurs DEL Clip et Limit s allument pour guider l utilisateur vers les niveaux de fonctionnement ap propriés L illumination de la DEL ...

Страница 8: ...rotection Excursion RMS HF Power Amplifier watts 300 watts Program 500 watts Peak HF Amplifier Type 3 Tier Class H LF Power Amplifier watts 900 watts Program 1600 watts Peak LF Amplifier Type Class D Cooling Scheme Convection Power Cable Removable Locking Powercon True Input and Loop Thru Output Power Switch Yes Power Consumption 200VA 320VA Max Inputs 1 XLR 2 x XLR Loop Input Sensitivity Vrms Sin...

Страница 9: ...Amplificateur de puissance HF watts 300 watts en programme 500 watts en crête Type d amplificateur HF Classe H à 3 rangées Amplificateur de puissance BF watts 900 watts en programme 1600 watts en pointe Type d amplificateur BF Classe D Schéma de refroidissement Convection Câble d alimentation Entrée Powercon True et sortie Loop Thru verrouillables et amovibles Commutateur d alimentation Oui Consom...

Страница 10: ...hat have worn or damaged insulation and remember to pull the plug not the cord to prevent damage to the cord Only replace with the equivalent heavy duty cord supplied by the manufacturer 4 The AC supply cord should be routed so that it is unlikely that it will be damaged Protect the power cord from being walked on or pinched If the AC supply cord is damaged DO NOT OPERATE THE UNIT To completely di...

Страница 11: ... pas de tirer sur la fiche et non sur le cordon pour éviter d endommager ce dernier Ne remplacez le cordon électrique que par un cordon équivalent à usage intensif fourni par le fabricant 4 Le cordon d alimentation CA doit être acheminé de manière qu il soit peu probable qu il soit endommagé Protégez le cordon d alimentation pour qu il ne soit pas piétiné ou pincé Si le cordon d alimentation CA es...

Страница 12: ...DSP ADC block diagram SYNERGY SA102 00 1v0 1 3 2 1 3 2 1 3 2 Input Output Output Clip Limit Act Level HP Adjust HF AMP LF AMP B l o c k D i a g ra m SA1 0 2 DE SIG N E D M AN U FAC T U R E D BY YO R KVILL E SO UN D Block Diagram ...

Страница 13: ...s de Yorkville Sound ou de votre détaillant Si pour une raison quelconque ce produit devient défectueux durant les deux années qui suivent la date d achat initial dix ans pour l ébénisterie retournez le simplement à votre détaillant Yorkville avec la preuve d achat original et il sera réparé gratuitement Ceci inclus tous les produits Yorkville à l exception de la série de moniteurs de studio YSM l...

Страница 14: ... Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound Limited 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Manual Owners SYNERGY SA102 00 1v3 August 29 2022 ...

Отзывы: