background image

SubSonic Filter

The 

SR300

 features a specially designed subsonic filter which effectively blocks potentially

destructive energy in the band below 35 Hz while slightly enhancing the band between 40 and 70
Hz. Engaging this filter produces the perception the same “bottom end”, while excessive and
possibly damaging excursions of the speaker cone are prevented. The filter provides an 12 dB/Oct
skirt below 35 Hz and 1dB boost at 50Hz. We recommend using this filter. With the filter disabled,
the 

SR300

 is flat down to 20 Hz, and rolls off at 12dB/Oct below that.

SPECIFICATIONS

Continuous Power:

  (Both Channels driven, 1 KHz, 0.1% THD)

8 Ohms 110 Watts (x2)
4 Ohms 150 Watts (x2)

Burst Power

:  (Both channels driven, 10m Sec of 1KHz, 0.1% THD)

8 Ohms 125 Watts (x2)
4 Ohms 195 Watts (x2)

Burst Power

:  (One channel driven, 10m Sec of 1KHz, 0.1% THD)

8 Ohms 140 Watts
4 Ohms 220 Watts

Frequency Response

: ±1 dB 20Hz - 20 KHz

±0.5 dB 20Hz - 20 KHz (typ.)

Hum and Noise:

< -95 dB re: 150W output ( typ, unweighted, 22Hz -22KHz BW)
< -98 dB re: 150W output ( "A" weighting)

Distortion:

(Both channels driven, -1 dBr full output, 80KHz BW)

<0.008% THD (typ, 1 KHz 8 Ohms)
<0.03% THD

(typ, 20 Hz - 20KHz, 8 Ohms)

<0.01% THD

(typ, 1 KHz 4 Ohms)

<0.1% THD

(typ, 20 Hz - 20KHz, 4 Ohms)

High Pass Filter:

-3dB at 35Hz, -12 dB/octave rolloff

Slew Rate:

>10 V/uSec

Damping Factor:

  >400 (20-400Hz, 8 Ohms)

Crosstalk:

< - 60 dB 1 KHz
< - 50 dB 20Hz - 20 KHz

Common Mode Rejection

: - 50 dB minimum / -65 dB typical at 60 Hz

Turn On/Off transient:

< 15 mW-Sec

Maximum Output Current:

10 A RMS burst, 7.5 A RMS Continuous

Power Consumption

: 200 Watts (typ), 500 W (max)

Transformer:

Toroidal

Protection:

Current Limit, Thermal Overload

Cooling:

Convection

Size:

38 cm x 48 cm x 9 cm 

(DWH)

15 in x 19 in x 3.5 in

(DWH)

2 Rack Spaces

Weight:

23 lbs. 10.3 Kg

3

Содержание SR 300

Страница 1: ...omsr300 pdf v 2 0 Aug 20 98 ...

Страница 2: ... DE CHOC ELECTRIQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT Veuillez lire le manuel Il contient des informations qui devraient êtres comprises avant l opération de votre appareil Conservez S V P ces instructions pour consultations ultérieures Emballage Conservez la boite au cas ou l appar...

Страница 3: ...e cycled burn in period and each circuit is tested by sophisticated computer controlled equipment which is capable of identifying any deviation from the design center parameters Balanced Inputs The SR300 has a high quality balanced input with high hum rejection The 1 4 inputs will accept a standard 1 4 TRS stereo plug for balanced operation The tip is the positive hot connection We recommend using...

Страница 4: ...visibly indicate any signal excursion beyond the dynamic headroom of the amplifier Signal LED s The signal LED s will indicate that a signal of low listening level is reaching the amplifier This is useful when troubleshooting the system If the LED s are active and no signal is heard from the speakers then the speaker wiring or the speakers are not working The activity LED s are connected after the...

Страница 5: ...95 Watts x2 Burst Power One channel driven 10m Sec of 1KHz 0 1 THD 8 Ohms140 Watts 4 Ohms220 Watts Frequency Response 1 dB 20Hz 20 KHz 0 5 dB 20Hz 20 KHz typ Hum and Noise 95 dB re 150W output typ unweighted 22Hz 22KHz BW 98 dB re 150W output A weighting Distortion Both channels driven 1 dBr full output 80KHz BW 0 008 THD typ 1 KHz 8 Ohms 0 03 THD typ 20 Hz 20KHz 8 Ohms 0 01 THD typ 1 KHz 4 Ohms 0...

Страница 6: ...dage à température variable Les circuiteries sont de plus individuellement testées par des appareils sofistiqués contrôlés par ordinateur qui sont capables d identifier toute déviations des paramêtres originaux Entrées symétriques Le SR300 est doté d entrées symétriques de haute qualité qui fournissent une exellente réjection de bourdonnement Les prises acceptent les fiches TRS standards stéréo po...

Страница 7: ...EL d activité indique qu un signal de bas niveau rejoint l amplificateur Pratique lors de dépannage de système Si la DEL est activée mais vous n entendez pas de signal aux haut parleurs le câblage est défectueux ou le les cabinets ne fonctionnent pas Les DEL d activité sont branchées après les contrôles de niveaux Les contrôles de niveaux doivent être élevés pour que les DEL d activité fonctionnen...

Страница 8: ... 4 Ohms195 Watts x2 Puissance d éclatement un canal 1KHz 10m Sec DHT 0 1 8 Ohms140 Watts 4 Ohms220 Watts Réponse en Fréquence 1 dB 20Hz 20 KHz 0 5 dB 20Hz 20KHz type Bruit et Bourdonnement 95 dB re sortie 150W type non pondérée 22Hz 22KHz BW 98 dB re sortie 150W pondérée A Distortion deux canaux 1 dBr sortie maximum 80KHz BW 0 008 DHT type 1KHz 8 ohms 0 03 DHT type 20Hz 20KHz 8 ohms 0 01 DHT type ...

Страница 9: ...Notes Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA SWITCHBOARD 905 837 8481 FAX 905 837 8746 ...

Страница 10: ...ate Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Quality and Innovation Since 1963 Printed in Canada ...

Отзывы: