 power amplifier is designed and built to provide years of trouble free performance. Although

specifically designed to power small studio monitors it has many other applications as well. Like all Yorkville Sound
amplifiers, it is designed to be rugged and reliable in all applications. The limiter and high pass filter are optimized to
increase the reliability of small studio monitors but can be used with higher power speakers as well. Generous current
capability along with low distortion and high headroom guarantee the sonic integrity of the power amplifier.

The 

SR300

 is designed and manufactured by Yorkville Sound. Each unit undergoes a temperature cycled burn-in

period, and each circuit is tested by sophisticated computer controlled equipment which is capable of identifying any
deviation from the design center parameters.

Balanced Inputs

The 

SR300

 has a high quality balanced input with high hum rejection. The 1/4" inputs will accept a

standard 1/4" TRS (stereo) plug for balanced operation. The tip is the positive (hot) connection. We
recommend using balanced connections wherever possible to ensure that the system is noise free.
Connecting a balanced input to an unbalanced output works very well giving almost all of the hum
rejection of a truly balanced inter-connection. The key to this connection is to use cable with 2 wires
plus a shield. The "ring" connection (return) should be connected to ground at the source ground. This
ensures that almost all of the hum created by the interconnection is canceled by the input circuit.

1

Содержание SR 300

Страница 1: ...omsr300 pdf v 2 0 Aug 20 98 ...

Страница 2: ... DE CHOC ELECTRIQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT Veuillez lire le manuel Il contient des informations qui devraient êtres comprises avant l opération de votre appareil Conservez S V P ces instructions pour consultations ultérieures Emballage Conservez la boite au cas ou l appar...

Страница 3: ...e cycled burn in period and each circuit is tested by sophisticated computer controlled equipment which is capable of identifying any deviation from the design center parameters Balanced Inputs The SR300 has a high quality balanced input with high hum rejection The 1 4 inputs will accept a standard 1 4 TRS stereo plug for balanced operation The tip is the positive hot connection We recommend using...

Страница 4: ...visibly indicate any signal excursion beyond the dynamic headroom of the amplifier Signal LED s The signal LED s will indicate that a signal of low listening level is reaching the amplifier This is useful when troubleshooting the system If the LED s are active and no signal is heard from the speakers then the speaker wiring or the speakers are not working The activity LED s are connected after the...

Страница 5: ...95 Watts x2 Burst Power One channel driven 10m Sec of 1KHz 0 1 THD 8 Ohms140 Watts 4 Ohms220 Watts Frequency Response 1 dB 20Hz 20 KHz 0 5 dB 20Hz 20 KHz typ Hum and Noise 95 dB re 150W output typ unweighted 22Hz 22KHz BW 98 dB re 150W output A weighting Distortion Both channels driven 1 dBr full output 80KHz BW 0 008 THD typ 1 KHz 8 Ohms 0 03 THD typ 20 Hz 20KHz 8 Ohms 0 01 THD typ 1 KHz 4 Ohms 0...

Страница 6: ...dage à température variable Les circuiteries sont de plus individuellement testées par des appareils sofistiqués contrôlés par ordinateur qui sont capables d identifier toute déviations des paramêtres originaux Entrées symétriques Le SR300 est doté d entrées symétriques de haute qualité qui fournissent une exellente réjection de bourdonnement Les prises acceptent les fiches TRS standards stéréo po...

Страница 7: ...EL d activité indique qu un signal de bas niveau rejoint l amplificateur Pratique lors de dépannage de système Si la DEL est activée mais vous n entendez pas de signal aux haut parleurs le câblage est défectueux ou le les cabinets ne fonctionnent pas Les DEL d activité sont branchées après les contrôles de niveaux Les contrôles de niveaux doivent être élevés pour que les DEL d activité fonctionnen...

Страница 8: ... 4 Ohms195 Watts x2 Puissance d éclatement un canal 1KHz 10m Sec DHT 0 1 8 Ohms140 Watts 4 Ohms220 Watts Réponse en Fréquence 1 dB 20Hz 20 KHz 0 5 dB 20Hz 20KHz type Bruit et Bourdonnement 95 dB re sortie 150W type non pondérée 22Hz 22KHz BW 98 dB re sortie 150W pondérée A Distortion deux canaux 1 dBr sortie maximum 80KHz BW 0 008 DHT type 1KHz 8 ohms 0 03 DHT type 20Hz 20KHz 8 ohms 0 01 DHT type ...

Страница 9: ...Notes Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA SWITCHBOARD 905 837 8481 FAX 905 837 8746 ...

Страница 10: ...ate Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Quality and Innovation Since 1963 Printed in Canada ...