background image

Introduction

The 

nx200s

 active subwoofer uses a 

200 watt 

amplifier to enhance the bottom end (bass) 

of a full-range speaker system. Using the 

nx200s

 does increase the overall output of 

the system slightly. The inputs to the subwoofer accept a single source either from a speaker/

amplifier output or a line level output from a pre-amp or mixer.

The 

nx200s

 is smooth and robust at high power levels because of efficient use of the 

built in 

limiter

 and 

thermal protection.

 The internal 

limiter

 and the internal protection are factory 

optimized for maximum performance.

SPEAKER

LINE

GND

GND LIFT

POWER

OFF

PARALLEL

INPUTS

MANUFACTURED AND DESIGNED BY

YORKVILLE SOUND TORONTO, CANADA

CAUTION AVIS

RISK OF ELECTRIC SHOCK

DO NOT OPEN

LEVEL

ON

ON

dB

+3

-3

-6

+10

+25

+20

0

50Hz  260VA

T1,25A

230V

110 VAC 

60Hz 260VA

AVERAGE

S

200

Yorkville

1

2

4

5

6

3

1. Power Switch
2. dB Level 

Set the dB Level control to a desired level as 

music is being played through the unit.

A setting of 0 dB on the dB LEVEL control 

is the correct starting point when setting 

up a sound system. From there the sound 

can be adjusted for best sound. The 0 dB 

mark refers to the setting that will give full 

power when the line input is used and the 

input signal is at a level of +4 dBV. This also 

is the setting to give a sensitivity of 2.83 

Vrms (1 watt 8-ohms) for 100 dB spl when 

set for speaker level input. With a typical full 

range companion speaker this will give flat 

response. In either line or speaker operation 

it will usually be desireable to set the control 

at +3 to +6 to give some bass boost at 

low power levels. At levels approaching full 

power the built-in limiter will automatically 

reduce the gain to prevent over powering 

the subwoofer. Operation with settings 

significantly above +12 may clip the circuitry 

in the subwoofer reducing the dynamics of 

the music. Setting the subwoofer gain above 

+12 is only appropiate at low operating levels.

3. Input Level Switch 

 

Speaker

 

Normally, the input to the subwoofer 

is from a full-range speaker cabinet, or 

amplifier output.(See figure 2)                       

                   

 

Line

 

In this case, the input to the subwoofer 

is from a line level source such as a mixer. 

4. Ground Lift

If a hum, or buzz is detected from the 

subwoofer, try setting the switch to the 

GND LIFT position (OUT position). The 

switch should otherwise be left in the 

GND (IN position). 

5. Input Jacks

The two inputs are balanced 1/4-inch parallel 

jacks and can be connected as shown in 

figures 2 and 3, on the following page. Please 

note that there is no effect to the performance 

of the full-range speaker if it is used to supply 

a music signal to the nx200s. 

6. Power On LED

Содержание NX200S

Страница 1: ...S 200 Yorkville OWNER S MANUAL MANUEL de L UTILISATEUR MODEL TYPE YS1019 ...

Страница 2: ...lacement of the obsolete outlet The AC supply cord should be routed so that it is unlikely that it will be damaged If the AC supply cord is damaged DO NOT OPERATE THE UNIT Unplug this apparatus during lightning storms or when unused for long periods of time Service The unit should be serviced only by qualified service personnel AVIS AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE N ENLEVEZ PAS LE CO...

Страница 3: ...he input signal is at a level of 4 dBV This also is the setting to give a sensitivity of 2 83 Vrms 1 watt 8 ohms for 100 dB spl when set for speaker level input With a typical full range companion speaker this will give flat response In either line or speaker operation it will usually be desireable to set the control at 3 to 6 to give some bass boost at low power levels At levels approaching full ...

Страница 4: ...es not have a U ground a ground pin on the AC cord the ground lift switch must be set to gnd The nx200s may be wired before or after the full range speakers The nx200s does not alter the signal to the full range speakers The nx200s will not draw any power from the amplifier driving the full range speakers Please note that an external crossover is not necessary Figure 2 Full Range Cabinet Full Rang...

Страница 5: ... coil current thermal Maximum SPL 125 dB 50 Hz to 110 Hz Power Requirements North American 110VAC 60 Hz 260 Watts Maximum European 230VAC 50 Hz 260 Watts Maximum Weight 54 lb 24 5 kg Dimensions WxDxH 17 5 inch x 27 inch x14 inch XX 44 5x68 6x35 6 cm Note The nx200s built in stand mounting adapter can be used with Yorkville SW Teletube accessory to support small fullrange cabinets approximately 16 ...

Страница 6: ...Commutateur de Niveau d Entree Haut Parleur Ce contrôle règle le niveau de sortie de l amplificateur figure 2 Ligne Dans ce cas le signal est acheminé au subwoofer à partir d une source de niveau de ligne sortie d une table de mixage 4 Découplange de Mise a la Terre Si un bourdonnement est détecté du subwoofer réglez le commutateur à la position GND LIFT position sortie Le commutateur devrait autr...

Страница 7: ... une mise à la terre sur le cordon d alimentation le commutateur de découplage de mise à la terre doit être réglé à la position GND Le nx200s peut être connecté avant ou après les haut parleurs pleine gamme L nx200s ne modifie pas le signal acheminé aux haut parleurs pleine gamme Le nx200s ne prélevera pas de puissance de l amplificateur qui propulse les haut parleurs pleine gamme Veuillez noter q...

Страница 8: ...e branchement Limiteur écrêtage courant moyen de la bobine mobile Pression Sonore Maximum 125 dB 50 Hz à 110 Hz Puissance Requise amérique du nord 110VAC 60 Hz 260 Watts Maximum europe 230VAC 50 Hz 260 Watts Maximum Poids 54 lb 22 5 kg Dimensions L x P x H 17 5 pouce x27 pouce x14 pouce 53x51x66 cm NOTEZ BIEN L adapteur de support nx200s peut être utilisé avec l accessoire YORKVILLE SW Teletube po...

Страница 9: ...e de faire enregistrer votre nom auprès de Yorkville Sound ou de votre détaillant Si pour une raison quelconque ce produit devient défectueux durant les deux années qui suivent la date d achat initial dix ans pour l ébénisterie retournez le simplement à votre détaillant Yorkville avec la preuve d achat original et il sera réparé gratuitement Ceci inclus tous les produits Yorkville à l exception de...

Страница 10: ...4625 Witmer Industrial Estate Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 ...

Отзывы: