background image

The exclamation point within an equilatereal triangle is intended to alert the 
user to the presence of important operating and maintenance (servicing) 
instructions in the literature accompanying the appliance.

Le point d’exclamation à l’intérieur d’un triangle équilatéral est prévu pour alerter 

l’utilisateur de la présence d’instructions importantes dans la littérature accompagnant 

l’appareil en ce qui concerne l’opération et la maintenance de cet appareil. 

This lightning flash with arrowhead symbol, within 
an equilateral triangle, is intended to alert the user to the presence of 
uninsulated “dangerous voltage” within the product’s enclosure that may be 
of sufficient magnitude to constitute a risk of electric shock to persons.

Ce symbole d’éclair avec tête de flèche dans un triangle équilatéral est prévu pour alerter 
l’utilisateur de la présence d’un « voltage dangereux » non-isolé à proximité de l’enceinte 
du produit qui pourrait être d’ampleur suffisante pour présenter un risque de choque 

_safety-5v0+UL60065-00-1v0 • October 28/2014

CAUTION

: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

THIS DEVICE IS FOR INDOOR USE ONLY!

Instructions pertaining to a risk of fire, electric shock, or injury to a person

Read Instructions: 

The Owner’s Manual should be read and understood before operation of your unit. Please, save these 

instructions for future reference and heed all warnings. 
Clean only with dry cloth.
Packaging: Keep the box and packaging materials, in case the unit needs to be returned for service.
Warning: To reduce the risk or fire or electric shock, do not expose this apparatus to rain or moisture. 

Do not 

use this apparatus near water!

Warning: When using electric products, basic precautions should always be followed, including the following:

Power Sources

Your unit should be connected to a power source only of the voltage specified in the owners manual or as marked on the 
unit. This unit has a polarized plug. Do not use with an extension cord or receptacle unless the plug can be fully inserted. 

Precautions should be taken so that the grounding scheme on the unit is not defeated. An apparatus with CLASS I 
construction shall be connected to a Mains socket outlet with a protective earthing ground. Where the MAINS plug or an 

appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.

Hazards

Do not place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious personal 
injury and serious damage to the product. Use only with cart, stand, tripod, bracket, or table recommended by the 
manufacturer or sold with the product. Follow the manufacturer’s instructions when installing the product and use mounting 

accessories recommended by the manufacturer. Only use attachments/accessories specified by the manufacturer
Note: Prolonged use of headphones at a high volume may cause health damage on your ears. 

The apparatus should not be exposed to dripping or splashing water; no objects filled with liquids should be 

placed on the apparatus.

Terminals marked with the “lightning bolt” are hazardous live; the external wiring connected to these terminals require 

installation by an instructed person or the use of ready made leads or cords.

Ensure that proper ventilation is provided around the appliance. Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

No naked flame sources, such as lighted candles, should be placed on the apparatus.

Power Cord

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the 
other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your 
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. The AC supply 
cord should be routed so that it is unlikely that it will be damaged. Protect the power cord from being walked on or pinched particularly 
at plugs. If the AC supply cord is damaged DO NOT OPERATE THE UNIT. To completely disconnect this apparatus from the AC 
Mains, disconnect the power supply cord plug from the AC receptacle. The mains plug of the power supply cord shall remain readily 

operable.

Unplug this apparatus during lightning storms or when unused for long periods of time.

Service

The unit should be serviced only by qualified service personnel. Servicing is required when the apparatus has been damaged in 

any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the 
apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

AVIS: 

AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE, N’ENLEVEZ PAS LE COUVERT

(OU LE PANNEAU ARRIERE) 

NE CONTIENT AUCUNE PIECE REPARABLE PAR L’UTILISATEUR.

CONSULTEZ UN TECHNICIEN QUALIFIE POUR L’ENTRETIENT

CE PRODUIT EST POUR L’USAGE À L’INTÉREUR SEULEMENT

Instructions relatives au risque de feu, choc électrique, ou blessures aux personnes

Veuillez Lire le Manuel: 

Il contient des informations qui devraient êtres comprises avant l’opération de votre appareil. 

Conservez. Gardez S.V.P. ces instructions pour consultations ultérieures et observez tous les avertissements.   
Nettoyez seulement avec le tissu sec.

Emballage: Conservez la boite au cas ou l’appareil devait être retourner pour réparation.
Avertissement: 

Pour réduire le risque de feu ou la décharge électrique, n'exposez pas cet appareil à la pluie ou à l'humidité. 

N’utilisez pas cet appareil près de l’eau!

Attention: Lors de l’utilisation de produits électrique, assurez-vous d’adhérer à des précautions de bases incluant celle qui suivent:

Alimentation

L’appareil ne doit être branché qu’à une source d’alimentation correspondant au voltage spécifié dans le manuel ou tel 

qu’indiqué sur l’appareil. Cet appareil est équipé d’une prise d’alimentation polarisée. Ne pas utiliser cet appareil avec un 

cordon de raccordement à moins qu’il soit possible d’insérer complètement les trois lames. Des précautions doivent êtres 
prises afin d’eviter que le système de mise à la terre de l’appareil ne soit désengagé.  Un appareil construit selon les normes 

de CLASS I devrait être raccordé à une prise murale d’alimentation avec connexion intacte de mise à la masse. Lorsqu’une 
prise de branchement ou un coupleur d'appareils est utilisée comme dispositif de débranchement, ce dispositif de 

débranchement devra demeurer pleinement  fonctionnel avec raccordement à la masse.

Risque

Ne pas placer cet appareil sur un chariot, un support, un trépied ou une table instables. L’appareil pourrait tomber et blesser 

quelqu’un ou subir des dommages importants. Utiliser seulement un chariot, un support, un trépied ou une table 

recommandés par le fabricant ou vendus avec le produit. Suivre les instructions du fabricant pour installer l’appareil et utiliser 

les accessoires recommandés par le fabricant. 

Utilisez seulement les attachements/accessoires indiqués par le fabricant

Note: L'utilisation prolongée des écouteurs à un volume élevé peut avoir des conséquences néfastes sur la santé 

sur vos oreilles. . 

Il convient de ne pas placer sur l’appareil de sources de flammes nues, telles que des bougies allumées.

L’appeil ne doit pas être exposé à des égouttements d’eau ou des éclaboussures et qu’aucun objet rempli de liquide tel 

que des vases ne doit être placé sur l’appareil.

Assurez que lappareil est fourni de la propre ventilation. Ne procédez pas à l’installation près de source de chaleur tels 

que radiateurs, registre de chaleur, fours ou autres appareils (incluant les amplificateurs) qui produisent de la chaleur.

Les dispositifs marqués d’une symbole “d’éclair” sont des parties dangereuses au toucher et que les câblages 

extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés par un opérateur formé ou en 
utilisant des cordons déjà préparés.

Cordon d’Alimentation

Ne pas enlever le dispositif de sécurité sur la prise polarisée ou la prise avec tige de mise à la masse du cordon d’alimentation. 

Une prise polarisée dispose de deux lames dont une plus large que l’autre. Une prise avec tige de mise à la masse dispose de 
deux lames en plus d’une troisième tige qui connecte à la masse. La lame plus large ou la tige de mise à la masse est prévu 
pour votre sécurité. La prise murale est désuète si elle n’est pas conçue pour accepter ce type de prise avec dispositif de 
sécurité. Dans ce cas, contactez un électricien pour faire remplacer la prise murale.  Évitez d’endommager le cordon 

d’alimentation. Protégez le cordon d’alimentation. Assurez-vous qu’on ne marche pas dessus et qu’on ne le pince pas en 
particulier aux prises.  N’UTILISEZ PAS L’APPAREIL si le cordon d’alimentation est endommagé. Pour débrancher 
complètement cet appareil de l’alimentation CA principale, déconnectez le cordon d’alimentation de la prise d’alimentation 

murale. Le cordon d’alimentation du bloc d’alimentation de l’appareil doit demeurer pleinement fonctionnel.

Débranchez cet appareil durant les orages ou si inutilisé pendant de longues périodes.

Service

Consultez un technicien qualifié pour l’entretien de votre appareil. L'entretien est nécessaire quand l'appareil a été endommagé de 
quelque façon que se soit. Par exemple si le cordon d’alimentation ou la prise du cordon sont endommagés, si il y a eu du liquide 
qui a été renversé à l’intérieur ou des objets sont tombés dans l'appareil, si l'appareil a été exposé à la pluie ou à l'humidité, si il ne 

fonctionne pas normalement, ou a été échappé.

S2125A

Caution: hot surface

Attention: surface chaude

IEC 60417-5041

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS (UL60065)

FOLLOW ALL INSTRUCTIONS

SUIVEZ TOUTES LES INSTRUCTIONS

The Lightning Flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated 
"dangerous voltage" within the product enclosure that may be of sufficient magnitude to constitute a risk of shock to persons

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance 
(servicing) instructions in the literature accompanying the product

 

 

1. Read these instructions. 
2. Keep these instructions. 
3. Heed all warnings. 
4. Follow all instructions. 
5. Do not use this apparatus near water. 
6. Clean only with dry cloth. 
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A 
grounding type plug has two blades and a third grounding prong. The wide blade or the third prongs are provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit 
from the apparatus. 
11. Only use attachments/accessories specified by the manufacturer. 
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution 
when moving the cart/apparatus combination to avoid injury from tip-over. 
13. Unplug this apparatus during lightning storms or when unused for long periods of time. 
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 
power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or 
moisture, does not operate normally, or has been dropped. 

WARNING: 

• To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases, should not be 
placed on this apparatus. 
• To completely disconnect this apparatus from the ac mains, disconnect the power supply cord plug from the ac receptacle. 
• The mains plug of the power supply cord or appliance coupler shall remain readily accessible. 

Le symbole représentant un éclair avec une flèche à l’intérieur d’un triangle équilatéral est utilisé pour prévenir l’utilisateur de la 
présence d’une tension électrique dangereuse non isolée à l’intérieur de l’appareil. Cette tension est d’un niveau suffisamment 
élevé pour représenter un risque d’électrocution

Le symbole représentant un point d’exclamation à l’intérieur d’un triangle équilatéral, signale à l’utilisateur la présence d’instructions 
importantes relatives au fonctionnement et à l’entretien de l’appareil dans cette notice d’installation

  

1. Lisez ces instructions. 
2. Conservez ces instructions. 
3. Respecter tous les avertissements. 
4. Suivez toutes les instructions. 
5. N'utilisez pas l'appareil près de l'eau. 
6. Nettoyer uniquement avec chiffon sec. 
7. Ne bloquez pas les ouvertures de ventilation. Installer en suivant les instructions du fabricant. 
8. Ne pas installer près des sources de chaleur telles que radiateurs, bouches de chaleur, four ou autres appareils (y compris les amplificateurs) 
produisant de la chaleur. 
9. N'annulez pas l'objectif sécuritaire de la fiche polarisée ou de la tige de mise à la terre. Une fiche polarisée possède deux lames avec une plus 
large que l'autre. Une prise avec mise à la terre possède deux lames et une troisième tige. La lame large ou la troisième tige sont fournis pour 
votre sécurité. Si la fiche n'entre pas dans votre prise, consultez un électricien pour remplacer la prise obsolète. 
10. Protéger le cordon d'alimentation des piétinements ou pincements en particulier près des fiches, des prises de courant et au point de 
sortie de l'appareil. 
11. Utilisez uniquement les accessoires spécifiés par le fabricant. 
12. Utiliser uniquement avec un charriot, stand, trépied ou une table spécifiée par le fabricant, ou vendus avec l'appareil. 
13. Débranchez l'appareil durant un orage ou lorsqu'il reste inutilisé pendant de longues périodes de temps. 
14. Confiez toute réparation à un technicien qualifié. Une réparation est nécessaire lorsque l'appareil a été endommagé de quelque façon que ce 
soit;  comme lorsque le cordon d'alimentation ou la fiche est endommagé, lorsque du liquide a été renversé ou des objets sont tombés à l'intérieur, 
lorsque l'appareil a été exposé à la pluie ou l'humidité, ne fonctionne pas normalement, ou est tombé. 

AVERTISSEMENT: 

• Pour réduire les risques d'incendie ou de choc électrique, ne pas exposer cet appareil à la pluie ou à l'humidité et ne placez pas d’objets contenant 
des liquides, tels que des vases, sur l’appareil.
• Pour isoler totalement cet appareil de l'alimentation secteur, débranchez totalement son cordon d'alimentation du réceptacle CA.
• La prise du cordon d’alimentation ou du prolongateur, si vous en utilisez un comme dispositif de débranchement, doit rester facilement accessible

CAUTION 

TO PREVENT ELECTRIC SHOCK HAZARD, 

DO NOT CONNECT TO MAINS POWER SUPPLY

WHILE GRILLE IS REMOVED. 

AVIS

POUR PRÉVENIR LES RISQUES D'ÉLECTROCUTION, 

NE PAS RACCORDER A L’ALIMENTATION ÉLECTRIQUE ALORS 

QUE LA GRILLE EST RETIRÉE. 

Содержание LP-LED2

Страница 1: ... SERVICE MANUAL LP LED2 TYPE YS1106 SMT Disclaimer Due to the complex nature of the use of SMT installed components in Yorkville equipment we highly caution all service technicians in attempting to repair or replace SMT factory installed components Many of these components may be glued prior to initial soldering Replacing SMT components requires expensive specialized de soldering equipment and tra...

Страница 2: ...a propre ventilation Ne procédez pas à l installation près de source de chaleur tels que radiateurs registre de chaleur fours ou autres appareils incluant les amplificateurs qui produisent de la chaleur Les dispositifs marqués d une symbole d éclair sont des parties dangereuses au toucher et que les câblages extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés pa...

Страница 3: ...2 DESIGNED MANUFACTURED BY YORKVILLE SOUND TORONTO CANADA C US Power Supply Component Approved by 1 Off 2 Lamp Color Off Off M I X E D F A D E D I M M E R COLOR F A D E Function 10 100 15 s 15 s 2 s 2 s 5 s 5 s 90 s 90 s OUT IN TO YORKVILLE CONTROLLERS DO NOT CONNECT TO DMX PWR CH Assign 1 2 3 4 OPTIONAL DMX PLUG IN Yorkville ...

Страница 4: ... Power Consumption LEDs 16 Watts per LED 4 LEDs per head 64 Watts total Power Consumption 270 Watts Stand Mount Size 1 3 8 inch Round Controller Cable Standard Shielded 3 pin XLR Cable Other Optional DMX Module Dimensions LWH 21 x 4 x 8 inches 53 4 x 10 2 x 20 3 cm ...

Страница 5: ...or Function Pot Ch1 2 3 4 Color Function Knob 6 6408 GRN 3MM LED 1V9 5MA FROSTED 18 9022 SPEAKER STAND ADAPTOR Power L E D 19 9026 6 32X1 1 8 BLK SOCKET HEAD CAP 7 8636 BUTTON 230X465 RND FLAT BLK 3425 Cluster lense mounting screw Channel Assign Knob LP LED2 ONLY 20 9029 KNOB TRIAD SOFT FEEL 10 32X 50 8 4526 10K TRIM POT 6MM TOP ADJ Stand mount and Light Pods Light Intensity Adjustment 21 9570 HEA...

Страница 6: ...R G B W_DW R2 G2 B5 S3 R16 LF KL LM EF MN_DW R2 G2 B4 T3 R17 LF KL LM EF MN_DW R2 G2 B4 T4 R18 LF KL LM EF MN_DW R2 G3 B4 T4 R19 LF KL LM EF MN_DW R2 G3 B4 R3 R20 LF KL LM EF MN_DW R2 G3 B4 S3 R21 LF DW R R2 G G3 B B4 W S3 R22 LF DW R R2 G G3 B B4 W T4 R23 LF DW R R2 G G2 B B4 W T3 R24 LF DW R R2 G G2 B B4 W T4 R25 LF DW R R2 G G3 B B5 W S3 R26 LF DW R R2 G G3 B B4 W T3 R27 LF KL LM FM_DW R2 G3 B5...

Страница 7: ...3 W100 20K0 1 0805 SMT RES 2 7693 __1N 50V 5 CAP 0805 SMT NPO 2 7693 __1N 50V 5 CAP 0805 SMT NPO 3 7725 48MHZ CRYSTAL 2 PIN NX SMT 1 7730 __2 2UH COIL SMT 2 7731 _68 0UH COIL SMT 8 7732 220 0UH COIL SMT 4 7734 __1U0 50V 10 CAP 1206 SMT CER 12 7735 __4U7 50V 10 CAP 1210 SMT CER 8 7738 _10U0 16V 10 CAP 1206 SMT X7R 2 7739 W250 1R 5 1206 SMT RES 4 7740 W125 698R 1 0805 SMT RES 2 7741 __2N2 50V 10 CAP...

Страница 8: ...8 W750 0R 1 2010 SMT JMP D7 7892 SMBJ26A 26V0 600W DIODE UNIDIR SMT R68 7998 W750 0R 1 2010 SMT JMP D8 7892 SMBJ26A 26V0 600W DIODE UNIDIR SMT R69 7998 W750 0R 1 2010 SMT JMP L1 7732 220 0UH COIL SMT R70 7998 W750 0R 1 2010 SMT JMP L2 7731 _68 0UH COIL SMT R71 7998 W750 0R 1 2010 SMT JMP L3 7731 _68 0UH COIL SMT R72 7998 W750 0R 1 2010 SMT JMP L4 7731 _68 0UH COIL SMT R73 7882 W250 0R 1206 SMT RES...

Страница 9: ...4 B 7979 RGBW LD2 B 7979 RGBW LD1 B 7979 RGBW LD2 A 7979 RGBW LD1 A 7979 4 3 6 7 2 8 1 5 S D G U4 7743 FDFS6N754 4 3 6 7 2 8 1 5 S D G U5 7743 FDFS6N754 RGBW LD4 A 7979 RGBW LD3 B 7979 RGBW LD3 A 7979 POWER PSOC ISSP PROGRAMMING HEADER R8 R10 W125 1206 W125 0R06 1 1206 SMT RES R12 W125 1206 W125 0R06 1 1206 SMT RES D D S S DD VSS VDD werPad 13 HCLK 12 CCLK 10 OCDE 47 FN0 2 46 FN0 1 22 CSN3 21 CSP3...

Страница 10: ...6A 2K0 1K0 0R FDFS6N754 FDFS6N754 RGBW 0R 0R RGBW 0R06 220UH Ferrite 1R0 0R06 0R 0R 0R Ferrite 0R 0R 68UH 1U 2 2UH 68UH 0R 5 CIR 470N 220UH FDFS6N754 10R0 68UH 4 CIR 68UH FAN HV GND HCLK V03 DRV 03 ICE_CCLK ICE_HCLK OCD_DE RST VDD M1482 80 MIL ALUMINUM SUBSTRATE SINGLE LAYER 2 OZ PCB LP LED4 POD BlankSize 6625 x 11120 C9 R23 R69 C4 D1 R70 R18 R4 R60 R61 C18 R14 D2 D5 C15 C5 R29 C11 C12 R7 R25 R53 ...

Страница 11: ...S SHOWN ON THE PARTS REEL IF THE NUMBER CANNOT BE IDENTIFIED ON THE REEL PLEASE CONTACT THE APPROPRIATE PERSON AT YORKVILLE SOUND LTD IMPORTANT NOTE DO NOT MIX LED PARTS FROM DIFFERENT REELS ON THE SAME BOARD PRODUCTION AND VENDOR NOTES 1 AI MOUNT SCREW AND WASHER IN LOCATION INDICATED YS 8925 4 INTERNAL TOOTH LOCKWASHER YS 8826 4 40 X 3 16 FLAT PHIL U C TRILOB ZC ...

Страница 12: ...RD HISTORY PENDING CHANGE X X X X X PC PC PC PC PC PC X LP LED4 M1482 PENDING CHANGES 12 9 6 3 13 11 10 5 4 8 7 2 1 DATE MODEL S VER DESCRIPTION OF CHANGE D D D V V V N N N D D D D D D V V V V V V N N N N N N V2 00 MAJOR REDESIGN MOVED U1 AND ADDED ESD CIRCUTRY ADDED ANOTHER GROUNDING SCREW LP LED4 LP LED4 POD PCB M1482 APRIL 29 2011 18 APR 2013 V03 REMOVE FAN2 CONN PANEL PC 8222 New LED pattern P...

Страница 13: ...100N 16V 10 CAP 0603 SMT X7R U1 7948 SN74AHC138 3 8 LINE DECODER DEMULTPLEXER C79 5979 100N 50V 5 CAP 0805 SMT X7R U2 7946 TLV2474AIDR QUAD OPAMP 2 8MHz C80 7767 100N 16V 10 CAP 0603 SMT X7R U3 7957 MCF52252 ColdFire Microcontroller C81 5979 100N 50V 5 CAP 0805 SMT X7R U4 8086 MMQA27V 27V 24W QUADUNIDIR SMT C83 7767 100N 16V 10 CAP 0603 SMT X7R U5 7661 LM393D Dual comparator SO 8 IC C84 7767 100N ...

Страница 14: ... 0805 1N C28 50V 10V0 D7 1W0 10V0 W125 10K R39 0805 W125 10K R54 0805 47K5 1 8W 0805 R53 0805 100N C90 50V 1 8W 1K0 R64 0805 W125 100K R22 0805 0805 100N C91 50V W125 4K7 R51 0805 0805 270P C4 50V 1K0 1 8W 0805 R3 6 5 7 TLV2474 U2 B 9 10 8 TLV2474 U2 C 1K0 1 8W 0805 R4 1 C0 2 A0 4 C2 6 C3 5 A1 3 C1 U4 8086 MMQA27V 2 4 W2 B 3 4 W2 C 4 4 W2 D GND C41 Ferrite FEMALE GND 3V3 3V3 UTXD0 3 4 W5 C 1 4 W8 ...

Страница 15: ...62 GND EXT CLOCK 10K W125 0805 R40 1M W125 0805 R38 0 1 2 COM 3 4527 P27 A ROT H Ch2 Color 0 1 2 COM 3 4527 P26 A ROT H Function X1 0603 100N C84 16V 0603 100N C85 16V T B P23 4526 M Lin 10K Function T B P25 4526 M Lin 10K Function GND EDSI URXD2 3V3POT MCF52252 L2 8108 120UH RAD 2in 100U C23 25V MBRA340T3 D61 Watts 0 1 2 COM 3 ROT H 4527 P1 A Ch1 Color 5 W7 E 10 4 W7 D 10 1 W7 A 10 3 W7 C 10 2 W7...

Страница 16: ...00NH MMBT3904 10K 100K SN74AHC138 NTS4409N 3A5 1K0 PTC 1K0 39R 680R 1N 100N 25V 100U 25V 100U 120UH 1N 10K 1K0 2K0 4K7 39R 48MHz 100N 100N 100N 22P 10U 4 CIR Ferrite LM2671 MBRA340T3 4 CIR BAS21DW5T1 47K5 10U 10K 10K 25V 100U TLV2474 MMQA27V LM393D 10K DPDT PUSH 10K 10K MCF52252AF80 10K 10K SN74LVTH125 IRF9530NS 10K ROT H ROT H ROT H BUTTON C Yorkville LP LED2 V03 2016 BlankSize 10800x7900 M1484 M...

Страница 17: ...2 3 4 1 DATE MODEL S VER DESCRIPTION OF CHANGE D V N 20 AUG 2012 V01 First release LP LED2 M1484_PCB_DATABASE_HISTORY 31 OCT 2012 V02 PC8491 Moved Q5 away from J1 ML 02 FEB 2016 V03 Implemented PC8856 and PC8857 Added fuses F1 and F2 YS 5062 to 24V net ...

Отзывы: