background image

w w w . y o r k v i l l e . c o m

w w w . y o r k v i l l e . c o m

REAL Gear.

REAL People.

REAL Gear.

REAL People.

Yorkville Sound

550 Granite Court

Pickering, Ontario

L1W-3Y8 CANADA

Canada Voice: 905-837-8481

Fax: 905-839-5776

Yorkville Sound Inc.

4625 Witmer Industrial Estate

Niagara Falls, New York

14305 USA

U.S.A. Voice: 716-297-2920

Fax: 716-297-3689

Yorkville Sound

550 Granite Court

Pickering, Ontario

L1W-3Y8 CANADA 

Canada Voice: 905-837-8481

Fax: 905-839-5776

Yorkville Sound Inc.

4625 Witmer Industrial Estate

Niagara Falls, New York

14305 USA

U.S.A. Voice: 716-297-2920

Fax: 716-297-3689

EXM Mobile Tower

Insert Spacer into

Woofer / Control Unit

Insert Spacer

into Spacer

Insert Speaker Array

into Spacer 

Optional

EXM MOBILE

TOWER ASSEMBLY

Single and 

Double Spacers

1

2

3

Top Panel

Channels - 

Tap each channel’s select button to configure Input Type, Voicing and Reverb.

Input Types - 

The Combi-jack inputs are used for mic, line or instrument sources, an 1/8-inch TRS 

stereo jack is included on Ch. 48V phantom power is available on the XLR portion of the jacks.

Voicing Selection - 

3 preset voicings (Music, Flat and Voice) can be set for each channel.

Reverb Control - 

A hall reverb is available on all 3 channels.  

Bluetooth™- 

The EXM Mobile Tower is capable of streaming Bluetooth™ audio. Disabled by default; to 

enable, connect or reconnect, tap the Bluetooth™ button. 

See Owner’s Manual for more info.

 

Pairing - 

Press the Bluetooth™ button and hold for 4 seconds, then release the button.

Status - 

The blue indicator displays the status of the connection. 

See Owner’s Manual for more info.

Level - 

Volume can be changed by the connected Bluetooth™ device or the Level control of Ch 3.

Stereo Mode - 

Stereo playback is supported between two EXM Mobile Towers. 

See Owner’s Manual for more info.

Button Operation - 

Single tap enables Bluetooth™ / double tap enters stereo mode / press & hold (4 

sec) enters pairing mode / press & hold (8 sec) disables Bluetooth™

Range - 

The Bluetooth™ operating range is rated for 10 meters (33 feet) line of sight. 

Note: When connected with Bluetooth™, ALL AUDIO is streamed from your device.  

Master Section

Master - 

Sets the overall level of the EXM Mobile Tower. 

Sub - 

Sets the relative level of the subwoofer, Typically set around noon. 

Modes - 

The two system modes alter the unit’s EQ and dynamics. Club mode for music playback and 

Live Mode for live performance.

Rear Panel

Main Input & Output - 

Jacks are in parallel. To use the Link feature, insert an XLR patch 

cable between cabinets.

USB Power Output - 

A USB power port provides a fixed output of 5V with up to 500mA of current 

and is used for power delivery only. 

Battery Status - 

A series of 4 green LEDs indicate the approximate charge level of the unit. 

Note: The indicators will be active only when the power switch is on - Enabling this feature helps extend 

the battery life of the unit. In Extended Life mode the output and dynamics of the system are adjusted 

to extend the total battery runtime of the system.

Charging Indicator

Whenever AC is connected to the unit, the colour of the power on button will indicate the charging status. 
If it is green, the unit is fully charged. If it is red, the unit is in the process of charging.

Charging the EXM Mobile Tower

To charge, plug into an AC power source using the included power cord. The indicator LED indicates  
the charging status. The EXM Mobile Tower can be used while charging. The EXM Mobile can also 
be safely left connected to AC power for charging indefinitely, it will intelligently control its own 
charging regime when plugged in long-term.

Battery life in full power mode will typically be 10 hours. 

(see Battery Performance Modes section in the Owner’s Manual)

The EXM Mobile will not charge when the temperature is below 0°C or above 45°C. If it is 

going to be stored unused for a long period of time (greater than 6 months) it is advisable to 

periodically plug it in to charge up the battery. If the EXM Mobile Tower has been stored for 

a long period of time unused and it has not been maintained, it is advisable to connect the 

charger and leave it plugged in for approximately 24 hours. 

To get the full Owner’s Manual please visit our website at 

http://www.yorkville.com/manuals/

 

or, if you need a printed version call 

905-837-8777

 

QuickStart-EXMMOBILET-00-1v1 • YS#QSTART-MOBILEST • March 22, 2023

Содержание EXM-Mobile-Tower

Страница 1: ...omponents requires expensive specialized de soldering equipment and training Yorkville Sound will repair and replace defective SMT components to ensure proper quality assurance and installation is mai...

Страница 2: ...ficateurs qui produisent de la chaleur Les dispositifs marqu s d une symbole d clair sont des parties dangereuses au toucher et que les c blages ext rieurs connect s ces dispositifs de connection ext...

Страница 3: ...RKVILLE SOUND TORONTO CANADA Made in China FUSE T2 0AL Aux In Power Fully Charged Charging Full Power Extended Life Battery Performance www yorkville com EXMMOBILET A EXMMOBILETR 1v0 EXM Mobile Tower...

Страница 4: ...nel 2 Controls Level Input Type Voicing Reverb Channel 3 Input XLR inch Combi jack 1 8 inch TRS Stereo Jack Channel 3 Controls Level Input Type Voicing Reverb Master Volume Control Master Level Sub Le...

Страница 5: ...Input Type Voicing Reverb Entr e Canal 3 Jack st r o TRS 1 8 pouce Combi jack XLR pouce Commandes Canal 3 Level Input Type Voicing Reverb Commande de Volume Principale Niveau Master Niveau Sub Link E...

Страница 6: ...FLAT VOICE Level Reverb INPUT TYPE VOICING EQ Dynamics Line Mic Inst EQ Dynamics MUSIC FLAT VOICE Level Reverb INPUT TYPE VOICING EQ EQ Dynamics EQ EQ Dynamics Line Live Club Mic Inst MODE EQ EQ EQ EQ...

Страница 7: ...P R50 7645 W100 475K 1 0805 SMT RES R153 7978 W500 3R3 5 1210 SMT RES C41 5242 100N 250V 20 CAP BLK X2 15MM AC D21 8275 MMBZ5252B 24V0 0W35 5 SMT ZEN R51 7625 W100 10K0 1 0805 SMT RES R154 7978 W500 3...

Страница 8: ...7 7767 100N 16V 10 CAP 0603 SMT X7R Q5B 7701 MMBTA14 NPN DARL SOT 23 SMT R61A 7761 W100 12K1 1 0603 SMT RES C40 7780 _10U 16V 20 CAP SMT ELC C86 7601 220N 50V 10 CAP 1206 SMT X7R C208A 5979 100N 50V 5...

Страница 9: ...1 0603 SMT RES R163 8039 W100 6K20 1 0603 SMT RES R276A 8218 W100 100R 1 0603 SMT RES R105 7758 W100 10K0 1 0603 SMT RES R164 8039 W100 6K20 1 0603 SMT RES R276B 8218 W100 100R 1 0603 SMT RES R106 775...

Страница 10: ...R121 W500 3R3 1210 R117 W500 3R3 1210 R122 W500 3R3 1210 R119 W500 3R3 1210 R123 W500 3R3 1210 R120 W500 3R3 1210 R124 6709 TPA3255 TSSOP44P GVDD_AB 1 VDD 2 M1 3 M2 4 INPUT_A 5 INPUT_B 6 OC_ADJ 7 FRE...

Страница 11: ...W500 3R3 1210 R154 W500 3R3 1210 R158 W500 3R3 1210 R165 W500 3R3 1210 R159 W500 3R3 1210 R166 W500 3R3 1210 R162 W500 3R3 1210 R167 W500 3R3 1210 R163 W500 3R3 1210 R168 6709 TPA3255 TSSOP44P GVDD_A...

Страница 12: ...W100 475K 0805 R5 W125 47K5 0805 R4 BuckGnd BuckGnd Enable 4X4mm 4U7 25V C1 4X4mm 4U7 25V C2 PMLL4148 SOD80 D2 PMLL4148 SOD80 D1 SOT 23 5V1 D11 24V 24V W100 100K0 0805 R12 W100 10K0 0805 R127 W125 750...

Страница 13: ...R 2512 R59 1W00 47R 2512 R62 1W00 47R 2512 R81 1W00 47R 2512 R82 1W00 47R 2512 R83 W100 100K0 0805 R53 W100 100K0 0805 R80 W100 1K0 0805 R69 W100 10K0 0805 R57 W100 10K0 0805 R66 W100 10K0 0805 R78 W1...

Страница 14: ...10K0 W100 0805 R126 SOT 23 24V D21 AC Gnd 24V VX 2 1 W5 1 2 W5 2 4244 SECONDARY 1 W6 1 2 W6 2 250V 100N X2 18MM C41 250V 4N7 Y 10MM C52 250V 680N X2 27MM C44 1300UH 6492 L9 120V 0V WHT BLK TS RED RED_...

Страница 15: ...D26 D27 R126 C29 BLK RED W7 BATTERY C26 C6 R22 C3 C16 4 C53 R130 R76 C63 C58 R139 R48 D29 C31 L7 C9 W11 L12 H MID HI AMP e e S N LABEL EXM Mobile Tower AMP M2204 SECONDARY FOR 2 BATTERIES USE W3 AND W...

Страница 16: ...R THE BUILD PCB HARDWARE SPECIAL PRODUCTION NOTES PCB ASSEMBLY DOCUMENTATION Gap Pad 4236 HW1 Place the 4236 pad onto U9 and U10 Handle the pad by the edges only Place Z1892 HS on top of U9 and U10 Se...

Страница 17: ...3V3 DGnd 3V3 DGnd DSP_Power 3V3 DGnd LP MP DP LP MP DP BTLed 12V 3V3 DGnd LEDGnd 12V MLeds_Power 3V3 12V 12V DGnd LEDGnd VPh 12V ChGnd IGnd 12V Input_Power 12V VPh IGnd 12V IP Master_Ana_Sig Aux_Mix A...

Страница 18: ...Gnd W100 10K0 0603 R195A 0805 50V 100N C61A W100 10K0 0603 R197A 0805 50V 100N C63A W100 470K 0603 R196A LineType PIC44A01 PIC44A02 COC44 PIC45A01 PIC45A02 COC45 PIC46A01 PIC46A02 COC46 PIC47A01 PIC47...

Страница 19: ...Gnd W100 10K0 0603 R195B 0805 50V 100N C61B W100 10K0 0603 R197B 0805 50V 100N C63B W100 470K 0603 R196B LineType PIC44B01 PIC44B02 COC44 PIC45B01 PIC45B02 COC45 PIC46B01 PIC46B02 COC46 PIC47B01 PIC47...

Страница 20: ...Gnd W100 10K0 0603 R195C 0805 50V 100N C61C W100 10K0 0603 R197C 0805 50V 100N C63C W100 470K 0603 R196C LineType PIC44C01 PIC44C02 COC44 PIC45C01 PIC45C02 COC45 PIC46C01 PIC46C02 COC46 PIC47C01 PIC47...

Страница 21: ...0805 R190 ChGnd D1005 CDSF4148 D18 D1005 CDSF4148 D19 W100 100R 0603 R198 W100 100R 0603 R93 D1005 CDSF4148 D1 ChClipC PIC4201 PIC4202 COC42 PIC4301 PIC4302 COC43 PIC6201 PIC6202 COC62 PIC6901 PIC690...

Страница 22: ...C77 4X4mm 16V 10U C76 1206 25V 1U C88 4X4mm 16V 10U C68 1206 25V 1U C72 W100 100R 0603 R176 W100 100R 0603 R188 0603 50V 2N2 C141 0603 50V 2N2 C142 DGnd DGnd LoSensM HiSensM LoM HiM HiM LoM PIC5501 P...

Страница 23: ...locks_DA BClkAD LRClkAD BClkBT LRClkBT Clocks_BT Clocks_BT LRClkBT BClkBT LRClkBT BClkBT 3V3 DGnd DSP_Power DSP_Power 3V3 DGnd DGnd DGnd DGnd DGnd DGnd DGnd DGnd DGnd W063 49R9 0603 R11 W063 49R9 0603...

Страница 24: ...DGnd WakeSig W100 1K02 0603 R166 DGnd 100N 0603 16V C124 WakeMCU WakeSig 3V3 CDSF4148 D1005 D4 CDSF4148 D1005 D9 Test_Sigma LineType LineType LineType 0805 50V 100P C146 DGND PIC2501 PIC2502 COC25 PI...

Страница 25: ...2_3 42 RST_N 43 P1_3 TCK_CPU SDA 47 P0_1 44 GND 50 P0_0 UART_TX_IND 49 P3_7 UART_CTS 48 P0_7 45 P1_2 TDI_CPU SCL 46 15X32mm SMT Module BM83 8550 U2 TxIndBT LRClkBT BClkBT DInBT P2_6 BTRst BTEn BTLed U...

Страница 26: ...N2 0603 50V C112 0603 50V 470P C110 4X4mm 16V 10U C111 OutGnd DGnd 12V AGnd 12V DGnd 12V 12V DGnd PGnd Out_Power W100 2K49 0603 R150 W100 7K32 0603 R152 OutGnd DGnd AGnd 12V 12V 100N 0805 50V C105 080...

Страница 27: ...D33 1 GRN 75 7036 LD33 2 7036 RED LD34 1 GRN 100 7036 LD34 2 PIC5801 PIC5802 COC58 PIC6401 PIC6402 COC64 PIC6601 PIC6602 COC66 PIC8701 PIC8702 COC87 PIC8901 PIC8902 COC89 PIC9001 PIC9002 COC90 PIC1390...

Страница 28: ...C107 PIC11901 PIC11902 COC119 PIC12001 PIC12002 COC120 PIC12101 PIC12102 COC121 PID4A01 PID4A02 COD4A PID4B01 PID4B02 COD4B PID4C01 PID4C02 COD4C PID601 PID602COD6 PILD401 PILD402 COLD4 PILD9A01 PILD9...

Страница 29: ...01 P A Q 2 2 0 3 COQ22 P A Q 2 3 0 2 PAQ2301 PAQ2303 COQ23 PAQ2402 PAQ2401 P A Q 2 4 0 3 COQ24 PAQ2503 PAQ2501 P A Q 2 5 0 2 COQ25 PAR101 PAR102 COR1 PAR202 PAR201 COR2 PAR402 PAR401 COR4 PAR501 PAR50...

Страница 30: ...9 13 Sheet Of PCB Rev Modified V01 File 2023 03 14 EXM Mobile Tower EML Rev 1 Tmp Date 04 15 2013 THIS SHEET CONTAINS SPECIAL PRODUCTION NOTES AND A LIST OF PCB HARDWARE PARTS REQUIRED FOR THE BUILD S...

Страница 31: ...O is streamed from your device Master Section Master Sets the overall level of the EXM Mobile Tower Sub Sets the relative level of the subwoofer Typically set around noon Modes The two system modes al...

Страница 32: ...permet d acc der au mode de jumelage un appui prolong 8 s permet de d sactiver le Bluetooth Port e La port e de fonctionnement de Bluetooth est valu e 10 m tres 33 pieds en ligne de mire Remarque lors...

Страница 33: ......

Отзывы: