Installation of Indoor Unit
Installation of Mounting Plate
1. Mounting plate should be installed horizontally. As the water tray's outlet for the indoor unit is two-way
type, during installation, the indoor unit should slightly slant to water tray's outlet for smooth drainage of
condenser water.
2.Fix the mounting plate on the wall with screws.
3.Be sure that the mounting plate has been fixed firmly enough to withstand about 60 kg. Meanwhile, the
weight should be evenly shared by every screw.
Fig.5
1.
2.
3.
Installation of Drain Hose
Connect the drain hose to the outlet pipe of the indoor unit.
Bind the joint with rubber belt.
Put the drain hose into insulating tube.
Wrap the insulating tube with wide rubber belt to prevent
the shift of insulating tube. Slant the drain
hose
downward
slightly for smooth drainage of condensing water.
Note: The insulating tube should be connected reliably with
the sleeve outside the outlet pipe. The drain hose should be
slanted downward slightly, without distortion, bulge or
fluctuation. Do not put the outlet in the water.
bulge
distortion
outlet pipe of
indoor unit
insulating tube
connected
insulating tube
drain hose
outlet pipe of
indoor unit
rubber belt
rubber belt
Flooded
Φ
55/
Φ70
Drill Piping Hole
1.Slant the piping hole (Φ55 / Φ70) on the wall slightly downward to the
outdoor side.
2.Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
Indoor
Outdoor
Wall pipe
Seal pad
25
24K UNIT:
09K TA UNIT:
254
146
846
316
Φ55
Φ55
09
、
12K TB UNIT:
Φ
55
Φ
55
Φ
70
Φ
70
18K UNIT:
685
185
319
55
69
130
1080
55
13
90
144
189
281
Φ
70
Φ
70
150
94
90
55
575
drain hose
outlet pipe of
indoor unit
outlet pipe of
indoor unit
rubber belt
35
135
60
156
34.5
160
10
80
35
254