Johnson Controls Unitary Products

Table 14: UB036 Charging Table

Table 15: UB042 Charging Table

Air Flow

Indoor Db/Wb

Outdoor

DB

Suction 

Pressure

Suction 

Temp.

Discharge 

Pressure

Liquid
Temp.

Delta T

Db

Entering 
Evap Db

Leaving 

Evap Db

Compressor

Amps

300 Cfm/Ton

80/62

75

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

85

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

95

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

300 Cfm/Ton

80/67

75

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

85

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

95

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

300 Cfm/Ton

80/72

75

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

85

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

95

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

300 Cfm/Ton

75/63

75

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

85

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

95

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

400 Cfm/Ton

80/62

75

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

85

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

95

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

400 Cfm/Ton

80/67

75

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

85

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

95

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

400 Cfm/Ton

80/72

75

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

85

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

95

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

400 Cfm/Ton

75/63

75

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

85

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

95

TBD

TBD

TBD

TBD

TBD

TBD

TBD

TBD

Air Flow

Indoor Db/Wb

Outdoor

DB

Suction 

Pressure

Suction 

Temp.

Discharge 

Pressure

Liquid
Temp.

Delta T

Db

Entering 
Evap Db

Leaving 

Evap Db

Compressor

Amps

300 Cfm/Ton

80/62

75

127

54

286

82

-29

80

51

11.4

85

130

56

331

93

-28

80

52

12.9

95

133

58

381

103

-27

80

53

14.6

300 Cfm/Ton

80/67

75

138

59

291

83

-24

80

56

11.5

85

142

62

335

93

-23

80

57

11.9

95

145

64

385

103

-22

80

58

13.4

300 Cfm/Ton

80/72

75

152

64

300

84

-19

80

61

11.7

85

154

65

345

94

-18

80

62

13.2

95

158

67

394

104

-17

80

63

14.9

300 Cfm/Ton

75/63

75

129

56

288

82

-23

75

52

11.5

85

133

58

332

93

-22

75

53

12.9

95

136

60

383

103

-21

75

54

14.7

400 Cfm/Ton

80/62

75

133

57

288

82

-27

80

53

11.5

85

135

59

333

93

-26

80

54

12.9

95

138

61

382

103

-25

80

55

14.6

400 Cfm/Ton

80/67

75

143

62

295

83

-23

80

57

11.6

85

147

64

340

93

-22

80

58

13.0

95

149

65

389

103

-21

80

59

14.7

400 Cfm/Ton

80/72

75

156

67

302

84

-18

80

62

11.8

85

159

67

345

94

-17

80

63

13.1

95

162

69

396

104

-16

80

64

14.9

400 Cfm/Ton

75/63

75

133

58

289

82

-22

75

53

11.5

85

137

59

334

93

-21

75

54

12.9

95

140

61

384

103

-20

75

55

14.7

Содержание UB0 Series

Страница 1: ...ance 5 3 Unit 4 Point Load Weight 6 4 Unit Dimensions 7 5 Return Air Box and Grille 8 6 Wye Installation Outlet 9 7 Wye Installation Inlet and Outlet 10 8 Duct Connector With Damper 10 9 Duct Connecto...

Страница 2: ...ed replacement parts Improper installation may create a condition where the operation of the product could cause personal injury or property damage Improper installation adjustment alteration service...

Страница 3: ...oling Only Product Identifier B 13 SEER Heat Pump Airflow A Standard Drive Installation Options A No Options Installed Voltage Code F 208 230 1 60 T 208 230 3 60 W 460 3 60 Product Style A Style A Add...

Страница 4: ...ed procedures identified by the Air Conditioning Contractors of America Figure 1 Component Location Direct Drive Condenser Fan Motor High Efficiency Enhanced Copper Tube Aluminum Fin Outdoor Coil High...

Страница 5: ...ruction See Figure 2 7 Wind direction The hot condenser air must be discharged up and away from the home or building and if possible in a direction with the prevailing wind 8 Relationship between buil...

Страница 6: ...per unit operation Figure 3 Unit 4 Point Load Weight C X Y CG D A B Right Left Front Rear Size Tons Weight lbs Center of Gravity 4 Point Load Location lbs Shipping Operating X Y A B C D 024 2 0 328 32...

Страница 7: ...F D CONDENSATE DRAIN 3 4 NPT H Table 2 Unit Dimensions Size Tons Dimensions A B C D E F G H 024 2 0 32 13 16 30 15 16 47 1 4 12 9 16 8 1 2 24 1 16 12 2 3 4 030 2 5 32 13 16 30 15 16 47 1 4 12 9 16 8 1...

Страница 8: ...be installed first The return air grille box and filter should be located and installed in the out rigger areas of the home Keep in mind the closer to the cooling unit the better The return ducting c...

Страница 9: ...ub collar in the raw end of the duct and tape securely in place 4 Make sure the duct is not stretched tight and does not have kinks from excessive length after installation 5 Attach the duct end with...

Страница 10: ...a register This will help to eliminate the transmission of sound into the home To locate the center of the duct first cut a 6 hole in the fiberboard below the duct at the desired location After locati...

Страница 11: ...eturn air ducts passing through unconditioned spaces of the building must be insulated and covered with a vapor barrier Following this practice will prevent thermal losses and condensate formation on...

Страница 12: ...accept a single circuit of supply power If an auxiliary heater is installed dual circuiting to the unit can be used When installing a 14 3 KW heater this method will avoid the use of large wiring To p...

Страница 13: ...7 Never locate it in a room that is warmer or cooler than the rest of the home such as a kitchen or hallway 8 The living or dining room is normally a good location provided there is no cooking range o...

Страница 14: ...e on If accessory heaters are not installed the blower will not run 9 Set the wall thermostat to the seasonal mode of operation heat or cool adjust the temperature selection lever to the desired setti...

Страница 15: ...0 F A forced defrost feature puts the system into a defrost period every 6 hours and 4 minutes to recirculate lubricants unless the coil temperature is above 40 F All defrost timing occurs only while...

Страница 16: ...8 1 17 2 19 9 47 8 51 1 60 60 60 60 2PH08520706 4 9 6 5 1 23 5 27 1 55 6 60 1 60 70 60 70 2PH08521006 7 2 9 6 1 34 5 39 8 69 4 76 70 80 70 80 2PH08521506 10 8 14 3 1 51 7 59 7 90 9 100 9 100 110 100 1...

Страница 17: ...l Scroll Scroll Scroll Scroll Quantity 1 1 1 1 1 1 CONDENSER COIL DATA Face area Sq Ft 11 1 11 28 11 28 16 16 20 Rows 1 2 2 2 2 2 Fins per inch 20 15 20 15 15 20 Tube diameter in 3 8 3 8 3 8 3 8 3 8 3...

Страница 18: ...1 High 2227 978 1086 1976 889 1129 1677 757 1151 048 4 0 Low 1260 275 807 1096 313 915 910 336 992 804 355 1057 774 290 979 Low Medium 1471 375 870 1338 415 968 1118 455 1079 963 474 1110 788 323 1016...

Страница 19: ...19 0 20 0 23 1200 0 21 0 21 0 21 0 22 0 25 1300 0 23 0 23 0 23 0 24 0 27 1400 0 25 0 25 0 25 0 26 0 29 1500 0 27 0 27 0 27 0 28 0 31 1600 0 29 0 29 0 29 0 30 0 33 1700 0 31 0 31 0 31 0 32 0 35 1800 0...

Страница 20: ...0 1300 1270 1270 060 5 0 208 230 1 60 1300 1300 1270 1270 Table 10 Indoor Blower Specifications Size Tons Motor HP RPM Eff SF Frame 024 2 0 1 2 1100 0 8 1 0 48 030 2 5 1 2 1100 0 8 1 0 48 036 3 0 1 2...

Страница 21: ...95 TBD TBD TBD TBD TBD TBD TBD TBD 400 Cfm Ton 75 63 75 TBD TBD TBD TBD TBD TBD TBD TBD 85 TBD TBD TBD TBD TBD TBD TBD TBD 95 TBD TBD TBD TBD TBD TBD TBD TBD Air Flow Indoor Db Wb Outdoor DB Suction P...

Страница 22: ...TBD TBD 85 TBD TBD TBD TBD TBD TBD TBD TBD 95 TBD TBD TBD TBD TBD TBD TBD TBD 400 Cfm Ton 75 63 75 TBD TBD TBD TBD TBD TBD TBD TBD 85 TBD TBD TBD TBD TBD TBD TBD TBD 95 TBD TBD TBD TBD TBD TBD TBD TB...

Страница 23: ...2 400 Cfm Ton 75 63 75 133 59 297 81 21 75 54 12 1 85 135 60 342 91 20 75 55 13 8 95 139 62 392 101 19 75 56 15 9 Air Flow Indoor Db Wb Outdoor DB Suction Pressure Suction Temp Discharge Pressure Liqu...

Страница 24: ...COIL Dirt should not be allowed to accumulate on the outdoor coil surface or other parts in the air circuit Cleaning should be as often as necessary to keep the coil clean Use a brush vacuum cleaner...

Страница 25: ...876572 BIM C 0213 Johnson Controls Unitary Products 25 Typical Wiring Diagrams UB024 060 Typical Heat Pump 208 230 1 60 volt Wiring Diagram...

Страница 26: ...876572 BIM C 0213 26 Johnson Controls Unitary Products UB036 048 and 060 Typical Heat Pump 208 230 3 60 volt Wiring Diagram...

Страница 27: ...876572 BIM C 0213 Johnson Controls Unitary Products 27 UB060 Typical Heat Pump 460 3 60 volt Wiring Diagram...

Страница 28: ...o change without notice Printed in U S A 876572 BIM C 0213 Copyright 2013 by Johnson Controls Inc All rights reserved Supersedes 876572 BIM B 1212 York International Corporation 5005 York Drive Norman...

Отзывы: