5167821-YTG-J-0518
Johnson Controls Ducted Systems
23
115°F
125°F
1000
77
33.8
3.0
-
20.8
13.1
-
-
-
28.9
3.4
-
20.4
11.8
-
-
-
72
32.3
3.0
-
23.8
18.0
12.3
-
-
28.8
3.4
-
22.7
16.8
10.9
-
-
67
30.8
3.0
-
26.7
23.0
17.2
11.5
-
28.4
3.4
-
24.9
21.8
15.9
10.0
-
62
30.4
3.0
-
29.1
27.9
22.2
16.5
10.8
28.0
3.4
-
27.4
26.8
20.8
14.8
8.9
1200
77
34.5
3.0
-
20.8
11.6
-
-
-
30.0
3.4
-
20.0
10.2
-
-
-
72
33.2
3.0
-
24.5
18.1
11.6
-
-
29.7
3.4
-
23.0
16.6
10.1
-
-
67
31.9
3.0
31.7
28.1
24.5
18.0
11.5
-
29.3
3.4
-
26.0
23.0
16.5
10.0
-
62
31.9
3.0
31.7
31.4
31.0
24.5
17.9
11.3
29.3
3.4
-
29.1
29.1
22.8
16.2
9.6
57
31.8
3.0
31.6
31.6
31.6
30.9
24.2
17.6
29.3
3.4
-
29.1
29.1
29.1
22.5
15.8
1400
77
35.2
3.0
31.7
20.9
10.0
-
-
-
31.1
3.3
30.6
19.5
8.5
-
-
-
72
34.0
3.0
32.3
25.2
18.1
11.0
-
-
30.6
3.4
30.3
23.3
16.3
9.3
-
-
67
33.1
3.0
32.9
29.5
26.1
18.9
11.6
-
30.3
3.4
30.1
27.1
24.1
17.0
9.9
-
62
33.3
3.0
33.0
33.0
33.0
26.7
19.3
11.8
30.6
3.4
30.2
30.2
30.2
24.8
17.6
10.4
57
33.6
3.0
33.1
33.1
33.1
33.1
27.0
19.3
30.9
3.4
30.3
30.3
30.3
30.3
25.2
17.9
1600
77
35.9
2.9
33.3
20.9
8.5
-
-
-
32.1
3.3
31.4
19.1
6.9
-
-
-
72
34.9
3.0
33.7
25.9
18.1
10.3
-
-
31.5
3.3
31.2
23.7
16.1
8.5
-
-
67
34.2
3.0
34.0
30.9
27.7
19.7
11.6
-
31.3
3.4
31.1
28.2
25.3
17.6
9.9
-
62
34.8
3.0
34.3
34.3
34.3
29.0
20.7
12.3
32.0
3.3
31.3
31.3
31.3
26.8
18.9
11.1
57
35.4
2.9
34.5
34.5
34.5
34.5
29.7
21.1
32.6
3.3
31.5
31.5
31.5
31.5
27.9
20.0
1800
72
35.7
2.9
35.0
26.6
18.1
9.7
-
-
32.4
3.3
32.2
24.0
15.9
7.7
-
-
67
35.4
2.9
35.2
32.3
29.3
20.5
11.6
-
32.3
3.3
32.1
29.3
26.5
18.2
9.9
-
62
36.3
2.9
35.6
35.6
35.6
31.3
22.1
12.8
33.3
3.3
32.4
32.4
32.4
28.7
20.3
11.9
57
37.2
2.9
35.9
35.9
35.9
35.9
32.5
22.8
34.2
3.3
32.7
32.7
32.7
32.7
30.7
22.1
2000
72
36.6
2.9
36.4
27.3
18.1
9.0
-
-
33.3
3.3
-
-
-
-
-
-
67
36.5
2.9
36.4
33.7
30.9
21.3
11.7
-
33.3
3.3
-
-
-
-
-
-
62
37.8
2.9
36.9
36.9
36.9
33.6
23.5
13.3
34.6
3.3
-
-
-
-
-
-
57
39.0
2.9
37.4
37.4
37.4
37.4
35.2
24.6
35.9
3.3
-
-
-
-
-
-
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZT049 Low Speed Compressor (4.0 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65