5219967-UTG-A-0716

2

Johnson Controls Unitary Products

Full Perimeter Base Rails -

 The easily removable base rails

provide a solid foundation for the entire unit and protects the
unit during shipment. The rails provide fork lift access from all
sides, and rigging holes are also provided so that an over-
head crane can be used to place the units on a roof. On
applications where the unit is placed on a pad, the base will
keep the unit off the pad to deter corrosion. On applications
where height is limited, the base rails may be removed by
removing 2 screws in each corner.

More Attractive Appearance -

 A single-piece top cover

containing a top-discharge outdoor fan arrangement requires
less square footage on installation and provides a wider vari-
ety of installations. The one-piece design adds greater water
integrity. Rounded corners with water drip edges add to the
attractive appearance.

Top Discharge -

 The top-discharge outdoor fan does not

disrupt neighboring areas or dry out vegetation surrounding
the unit. The warm air from the top mounted fan is blown up
and away from the structure and any landscaping. This
allows compact location on multi-unit applications.

Outdoor Coil Grille -

 All models utilize a stamped slotted

design which provides superior impact protection against
small objects during transit and after installation.

Low Operating Sound Level -

 The upward air flow carries

the normal operating noise up and away from the living area.
The rigid top panel effectively isolates noise. Isolator
mounted compressor and the rippled fins of the outdoor coil
muffle the normal fan motor and compressor operating
sounds. The uniquely formed base pan also aids in sound
attenuation with its structural design. This design strategi-
cally places embossments in the pan for optimum strength
and rigidity.

Fan System -

 All models operate over a wide range of

design conditions with an enhanced ECM indoor fan motor.
These units easily match all types of applications and pro-
vide greater on-site flexibility to match comfort requirements.
The cooling speed is factory-set and can be field-adjusted to
a second speed. The heating speed is factory set to maintain
mid point rise at the units heating input, but can be field
adjusted. This allows maximum comfort conditions.

Simple Control Circuit -

 A low voltage gas heat printed cir-

cuit board contains a status/diagnostic indicator light. Field
thermostat wiring connects to color coded leads using twist
on wire connections. Cooling controls use contactor and
relays for simple application and troubleshooting. Mate-n-
lock plug connectors are used. The electrical control box is
not located in the compressor compartment. The controls are
mounted to allow the separate access panel to be removed
for trouble shooting and maintenance without affecting the
normal system operating pressures. All wiring internal to the
unit is color/number coded.

Protected Compressor -

 The compressor is internally pro-

tected against high pressure and temperature. This is
accomplished by the simultaneous operation of high pres-
sure relief valve and a temperature sensor which protect the
compressor if undesirable operating conditions occur.

Pressure Switches -

 A high pressure switch is standard in

all units. It is an automatic reset switch. When discharge
pressure reaches 650 psi, the compressor de-energizes until
pressure reaches 450 psi. 

Exclusive Coil Design -

 Grooved copper tubes and

enhanced aluminum fin construction improves heat transfer
for maximum efficiency and durability for long-lasting durabil-
ity and efficient operation. Indoor coils use tin-coated copper
tubing with aluminum fins for effective heat transfer.

Heat Exchangers -

 Gas heat exchangers use corrosion-

resistant, stainless-steel tubular construction to provide long-
life, trouble-free operation. Gas heat exchangers are offered
with lifetime warranties as standard with registration.

Post Purge Induced Draft Combustion -

 Exhausts com-

bustion products from the heat exchanger upon completion
of the heating cycle to prolong the heat exchanger life.

Spark To Burner Ignition -

 No pilot assembly required,

which provides more consistent ignition in gas heating mode.
This ignition is highly reliable, durable and eliminates nui-
sance lockouts.

Multi Port In-shot Burners -

 No field adjustment is required

to mix the air and gas for natural gas or propane use. These
burners are constructed of high-grade corrosion-resistant,
aluminized steel.

Low Maintenance -

 Long life, permanently lubricated out-

door and evaporator fan motor bearings need no annual
maintenance, adding greater reliability to the unit. Slide-out
blower assembly can be easily removed for cleaning.

Easy Service Access -

 Individual access panels covering

the electrical and gas controls makes servicing easy. Remov-
ing this panel will allow easy removal of the blower assembly
for maintenance and ease of troubleshooting.

Replacement Parts -

 The installer requires no special train-

ing to replace any of the components of these units and the
number of new components have been reduced to minimize
the inventory of unique parts.

Loss of Charge Sensor (S1-2LC00024) -

 Kit provides Loss

of Charge sensor and wiring to provide safe shutdown of
compressor.

Transition Curb Kits (S1-1TC01*) -

 Adapter kits to allow

field use of pre-existing installed roof curbs to match PH*6
footprint to Affinity roof curbs, Carrier, Trane, or Goodman
curb footprints. Curb adapters are optional for current gener-
ation Carrier replacements but are recommended for previ-
ous generation applications. Refer to the PC*6 price pages
for more details.

Содержание PCG6 24 Series

Страница 1: ...t Test stations using a state of the art computerized process system are used to ensure product quality Refrigerant charge and component part numbers are verified via computers during assembly Vital run test statistics such as system pressure motor cur rents air velocity and temperature unit vibration and gas system safeties are monitored and recorded by the system to ensure unit performance Equal...

Страница 2: ...re mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures All wiring internal to the unit is color number coded Protected Compressor The compressor is internally pro tected against high pressure and temperature This is accomplished by the simultaneous operation of high pres sure relief valve and a temper...

Страница 3: ...000 BTU etc 9 Revision Level A original release B second release Examples PCG4B421002X1A is a packaged A C with gas heat 14 SEER 3 1 2 ton large cabinet single stage heat 100 000 BTU gas heat 230 volt single phase low NOx model first generation first release COMPONENT LOCATION FAN MOTOR OUTDOOR FAN COIL GUARD PANEL OUTDOOR COIL Behind Panel CONTROL BOARD TRANSFORMER HIGH VOLTAGE CONTACTOR PRESSURE...

Страница 4: ...pable of providing 0 through 50 of outdoor air field supplied Closes on power loss includes hood and screen assembly Rectangle to Round Horizontal Adapter S1 1AK0110 S1 1AK0111 Kit includes one supply and one return air rectangle to round duct adapter Adapters are preformed and designed to fit over current horizontal duct openings on the base unit Transition is from rectangle to 12 round for the 1...

Страница 5: ...gn Fan wheel shall be double inlet type with forward curved blades dynamically balanced to operate smoothly throughout the entire range of operation Airflow design shall be constant air volume Bearings shall be sealed and permanently lubricated for longer life and no maintenance Fan assembly shall be a slide out design for easy removal and cleaning Indoor blower motors shall be equipped with a sta...

Страница 6: ... inches Length 51 1 4 51 1 4 51 1 4 51 1 4 51 1 4 51 1 4 Width 35 3 4 35 3 4 45 3 4 45 3 4 45 3 4 45 3 4 Height 47 47 49 49 53 55 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Condenser Coil Data Face area Sq Ft 15 1 15 1 19 5 19 5 23 8 25 9 Rows 1 2 2 2 2 2 Fins per inch 22 22 22 22 22 22 Tube diameter 3 8 3 8 3 8 3 8 3 8 3 8 Circuitry Type Interlaced Interlaced Interlaced Interlaced ...

Страница 7: ...4 9 4 10 2 6 9 12 1 11 3 10 7 12 1 8 1 K W 1 59 1 58 1 58 1 55 1 56 1 54 1 53 1 54 1 52 1 53 1 49 1 48 1 50 1 48 1 50 COOLING PERFORMANCE DATA 2 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6A24 CONDENSER ENTERING AIR TEMPERATURE ID CFM 600 800 1000 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 26 0 28 6 28 4 30 0 31 7 28 0 29 9 29 7 31 2...

Страница 8: ... 4 11 2 10 9 11 5 8 7 10 5 11 5 11 7 12 9 9 9 K W 2 71 2 71 2 70 2 69 2 71 2 69 2 69 2 69 2 67 2 70 2 66 2 66 2 67 2 66 2 70 COOLING PERFORMANCE DATA 2 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6A30 CONDENSER ENTERING AIR TEMPERATURE ID CFM 750 950 1150 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 31 5 35 1 34 4 39 1 42 4 34 1 37 4 ...

Страница 9: ... 2 22 8 19 4 21 0 13 9 23 6 24 5 22 4 23 4 14 7 K W 5 60 5 58 5 55 5 54 5 46 5 52 5 53 5 53 5 49 5 42 5 44 5 48 5 51 5 44 5 38 COOLING PERFORMANCE DATA 3 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6B36 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1000 1200 1400 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 45 0 53 3 52 6 55 8 57 3 47 0 52 ...

Страница 10: ...7 14 6 17 3 18 5 11 7 15 6 15 6 19 3 20 8 13 1 K W 2 45 2 45 2 42 2 44 2 42 2 46 2 46 2 44 2 45 2 43 2 47 2 47 2 46 2 45 2 44 COOLING PERFORMANCE DATA HIGH 3 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6B42 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1120 1320 1520 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 43 6 47 7 30 8 50 0 55 0 45...

Страница 11: ...4 17 5 12 5 20 4 11 4 17 9 17 6 11 8 22 3 12 1 K W 3 98 4 10 3 98 3 91 3 89 3 99 4 05 4 00 3 92 3 93 4 00 4 01 4 02 3 93 3 97 COOLING PERFORMANCE DATA HIGH 4 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6B48 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1400 1600 1800 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 46 5 54 3 55 5 56 6 59 6 47 9...

Страница 12: ... 24 3 27 5 24 6 25 9 18 4 25 1 26 7 25 2 27 5 19 6 K W 4 57 4 38 4 39 4 35 4 32 4 58 4 47 4 49 4 46 4 43 4 58 4 57 4 59 4 56 4 54 COOLING PERFORMANCE DATA 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6B60 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1600 1800 2000 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 59 2 68 9 66 5 71 8 77 1 61 3 ...

Страница 13: ...f covering materials only if factory base rails are left in place as shipped 1 INDOOR BLOWER SPECIFICATIONS Model Motor HP RPM EFF SF Frame 24050 30050 1 3 Variable 0 8 1 0 48 24075 30075 36065 1 2 Variable 0 8 1 0 48 36100 42065 42100 48065 48100 48125 3 4 Variable 0 8 1 0 48 60065 60100 60125 1 Variable 0 8 1 0 48 SOUND PERFORMANCE Model Tons Sound Rating1 dB A 1 Rated in accordance with AHRI St...

Страница 14: ...152 9 42 0 1 7 7 0 42 3 60 1 Minimum Circuit Ampacity 2 Maximum Over Current Protection per standard UL 1995 3 Fuse or HACR circuit breaker size installed at factory or field installed WEIGHTS DIMENSIONS Model Weight lbs Center of Gravity 4 Point Load Location lbs Shipping Operating X Y A B C D 24050 372 367 28 15 120 95 81 71 24075 382 377 28 15 124 96 81 76 30050 417 412 28 15 139 99 90 84 30075...

Страница 15: ...1 B 927 867 813 761 717 667 612 561 524 487 C 870 761 699 649 605 539 484 449 422 370 D 799 623 552 475 436 387 338 294 237 192 Low Cool A 902 822 764 713 669 612 557 513 480 437 B 855 734 669 615 572 509 454 418 385 334 C 827 678 611 545 504 448 396 356 311 263 D 675 546 466 404 347 277 205 160 126 80 High Heat A 1184 1161 1124 1084 1041 994 954 913 872 822 B 1076 1047 1011 967 912 875 833 790 73...

Страница 16: ...02 709 646 582 528 467 402 C 882 805 741 625 556 501 415 359 297 228 D 805 718 642 523 436 376 294 247 193 118 High Heat A 1126 1067 1006 945 860 777 718 664 608 551 B 1015 952 884 802 709 646 582 528 467 402 C 955 886 821 721 642 584 508 453 391 324 D 910 836 774 661 592 537 453 396 333 265 Low Heat A 970 902 837 742 659 599 527 472 410 343 B 818 732 659 540 456 397 314 265 211 136 C 766 674 593 ...

Страница 17: ...8 907 839 785 733 663 598 C 1025 966 892 823 756 684 625 575 494 427 D 964 900 816 742 672 596 534 485 398 329 High Heat A 1704 1667 1645 1612 1572 1520 1477 1419 1384 1327 B 1506 1468 1441 1404 1358 1302 1259 1203 1159 1101 C 1322 1278 1238 1191 1138 1077 1030 975 920 859 D 1251 1205 1157 1107 1051 987 938 884 824 761 Low Heat A 1392 1352 1318 1276 1226 1168 1123 1067 1017 957 B 1251 1205 1157 11...

Страница 18: ...374 1333 1298 1255 1204 1145 1100 1044 993 933 C 1322 1278 1238 1191 1138 1077 1030 975 920 859 D 1286 1241 1197 1149 1095 1032 984 930 872 810 High Heat A 2114 2046 1974 1914 1874 1815 1745 1696 1645 1582 B 1982 1930 1887 1844 1806 1752 1697 1643 1604 1545 C 1785 1746 1720 1687 1647 1596 1551 1494 1459 1402 D 1614 1578 1554 1520 1477 1424 1382 1324 1286 1228 Low Heat A 2114 2046 1974 1914 1874 18...

Страница 19: ...155 1100 1044 992 938 D 1323 1270 1213 1156 1104 1052 993 933 880 821 Low Heat A 1594 1553 1507 1462 1415 1369 1321 1274 1223 1178 B 1323 1270 1213 1156 1104 1052 993 933 880 821 C 1181 1118 1049 980 913 857 795 743 696 640 D 1025 950 868 788 713 654 591 505 458 415 60125 Continuous Fan A 2077 2043 2006 1961 1922 1880 1836 1789 1744 1696 B 1879 1843 1807 1763 1723 1679 1635 1590 1536 1493 C 1683 1...

Страница 20: ... 02 0 01 0 06 900 0 03 0 01 0 08 1000 0 04 0 01 0 10 1100 0 05 0 01 0 13 1200 0 06 0 02 0 16 1300 0 07 0 03 0 17 1400 0 08 0 04 0 18 042 3 5 1100 0 02 0 02 0 04 1200 0 03 0 02 0 04 1300 0 04 0 02 0 05 1400 0 05 0 03 0 05 1500 0 06 0 04 0 06 1600 0 07 0 04 0 07 1700 0 07 0 04 0 08 1800 0 08 0 04 0 09 1900 0 09 0 05 0 10 2000 0 09 0 05 0 11 048 4 0 1100 0 02 0 02 0 04 1200 0 03 0 02 0 04 1300 0 04 0...

Страница 21: ...REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A0324 001 UNIT TYPICAL SLAB ON GROUND INSTALLATION A0325 001 SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH CONTROL WIRING TO INDOOR THERMOSTAT TO GAS SUPPLY LINE MANUAL GAS SHUTOFF VAVLE CONDENSATE DRAIN ...

Страница 22: ...Measure the supply air static pressure Record this positive number Measure the return air static pressure Record this negative number Treat the negative number as a positive and add the two numbers together This is total system static UNIT TYPICAL ROOF CURB INSTALLATION SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH CONTROL WIRING TO INDOOR THERMOSTAT TO GAS SUPPL...