Johnson Controls Unitary Products
115°F
125°F
3000
77
116.8
12.1
58.7
46.2
33.7
-
-
-
111.5
13.3
57.0
44.4
31.8
-
-
-
72
106.7
11.9
75.9
63.4
50.9
38.4
-
-
100.7
13.2
73.6
61.1
48.5
35.9
-
-
67
96.6
11.8
93.2
80.7
68.2
55.7
43.2
-
89.9
13.1
89.9
77.7
65.1
52.6
40.0
-
62
89.7
11.7
89.7
89.7
83.3
70.8
58.3
45.8
84.4
12.9
84.4
84.4
80.0
67.5
54.9
42.3
57
93.0
11.7
93.0
92.9
80.4
67.9
55.4
42.9
87.9
12.9
87.9
87.9
75.5
62.9
50.3
37.8
3500
77
122.7
12.1
71.5
52.0
37.7
-
-
-
116.2
13.3
72.4
50.2
35.8
-
-
-
72
112.1
11.9
85.6
71.3
57.0
42.7
-
-
105.0
13.2
83.3
68.9
54.5
40.1
-
-
67
101.4
11.8
99.7
90.6
76.3
62.0
47.7
-
93.7
13.1
93.7
87.6
73.2
58.8
44.4
-
62
94.2
11.7
94.2
94.2
93.2
78.9
64.6
50.3
88.0
12.9
88.0
88.0
88.0
75.8
61.1
46.7
57
97.7
11.7
97.7
97.6
90.0
75.7
61.4
47.1
91.5
13.0
91.5
91.5
84.8
70.9
56.0
41.6
4000
77
128.6
12.1
84.3
57.8
41.7
-
-
-
120.9
13.3
87.7
56.0
39.7
-
-
-
72
117.4
11.9
95.3
79.2
63.1
46.9
-
-
109.2
13.2
93.0
76.8
60.5
44.2
-
-
67
106.3
11.8
106.3
100.5
84.4
68.3
52.2
-
97.4
13.1
97.4
97.4
81.3
65.0
48.8
-
62
98.8
11.7
98.8
98.8
103.1
87.0
70.9
54.8
91.5
12.9
91.5
91.5
91.5
84.2
67.3
51.1
57
102.3
11.7
102.3
102.3
99.6
83.5
67.3
51.2
95.2
13.0
95.2
95.2
94.2
78.8
61.7
45.4
4500
72
122.9
12.0
103.0
85.3
67.6
49.9
-
-
114.7
13.2
100.8
82.9
65.0
47.0
-
-
67
111.2
11.8
111.2
108.2
90.5
72.8
55.1
-
102.4
13.1
102.4
102.4
87.3
69.3
51.4
-
62
103.3
11.7
103.3
103.3
105.5
87.8
70.1
52.4
96.1
12.9
96.1
96.1
96.1
82.6
64.4
46.5
57
107.1
11.7
107.1
107.1
105.7
88.0
70.3
52.6
100.0
13.0
100.0
100.0
99.5
82.0
63.6
45.7
5000
72
128.3
12.0
110.8
91.5
72.2
52.9
-
-
120.2
13.3
108.7
89.0
69.4
49.8
-
-
67
116.1
11.9
116.1
115.9
96.6
77.3
58.0
-
107.3
13.2
107.3
107.3
93.3
73.7
54.1
-
62
107.9
11.7
107.9
107.9
107.9
88.6
69.3
50.0
100.7
13.0
100.7
100.7
100.7
81.1
61.5
41.9
57
111.8
11.8
111.8
111.8
111.8
92.5
73.2
53.9
104.8
13.0
104.8
104.8
104.8
85.2
65.6
46.0
1
These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower
Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746
nameplate rated motor
efficiency.
2
These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor.
YD120/ND120/NM120
(Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65
Содержание NC090-300
Страница 73: ...505428 YTG V 0417 Johnson Controls Unitary Products 73 Typical YC120 150 Wiring Diagram...
Страница 74: ...505428 YTG V 0417 74 Johnson Controls Unitary Products Typical YD120 150 Wiring Diagram...
Страница 75: ...505428 YTG V 0417 Johnson Controls Unitary Products 75 Typical YC180 Wiring Diagram...
Страница 76: ...505428 YTG V 0417 76 Johnson Controls Unitary Products Typical YC240 Wiring Diagram...
Страница 77: ...505428 YTG V 0417 Johnson Controls Unitary Products 77 Typical YC300 Wiring Diagram...
Страница 78: ...505428 YTG V 0417 78 Johnson Controls Unitary Products Typical YD180 240 Wiring Diagram...
Страница 79: ...505428 YTG V 0417 Johnson Controls Unitary Products 79 Heat Pump Units Typical PC090 Wiring Diagram...
Страница 80: ...505428 YTG V 0417 80 Johnson Controls Unitary Products Typical PC120 Wiring Diagram...
Страница 81: ...505428 YTG V 0417 Johnson Controls Unitary Products 81 Typical PC180 Wiring Diagram...
Страница 82: ...505428 YTG V 0417 82 Johnson Controls Unitary Products Typical PD180 240 Wiring Diagram...
Страница 83: ...505428 YTG V 0417 Johnson Controls Unitary Products 83 Air Handling Units Typical NC090 Wiring Diagram...
Страница 87: ...505428 YTG V 0417 Johnson Controls Unitary Products 87 Typical NC300 Indoor Unit Wiring Diagram...
Страница 118: ...505428 YTG V 0417 118 Johnson Controls Unitary Products Typical Field Wiring Diagram NC300 Evaporator...