CONFORMITY DECLARATION

AS DEFINED BY MACHINERY DIRECTIVE 89/392 EEC ANNEXE II A

        

WE  :            YORK Industrial (Thailand) Co., Ltd.

                104 Moo 2, Teparak Rd., Tambon Bangsaothong

                King-Ampher Bangsaothong. Samutprakarn 10540, Thailand.

    

DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE MACHINE :

    

 Outdoor unit        MOC 07 to 55 and MOH 07 to 55

                

DESIGNATION :

  Indoor units         MCC 07 to 35 , MCH 07 to 35,

                           MSC 35 to 55, MSH 35 to 55,

                           MKC 12 to 55, MKH 12 to 55,

                          MAC 18 to 55, MAH 18 to 55

              

IS IN COMPLIANCE WITH REQUIREMENTS OF :

              •  MACHINERY DIRECTIVE CEE 89/392 AS MODIFIED WITH DIRECTIVES

                 CEE 91/368, 93/44, 93/68 (EEC 91/368, 93/44 AND 93/68)

              •  LOW VOLTAGE DIRECTIVE CEE73/23 (EEC 73/23)

              •  ELECTROMAGNETIC COMPATIBILITY DIRECTIVE CEE 89/336 (EEC 89/336)

                 

EC type certificate TCF n° 277

              IN ACCORDANCE WITH THE FOLLOWING HARMONIZED STANDARDS :

              •  EN 292/1, EN 292/2, EN 292-2A1, EN 60335-2-40, EN 50081-1, EN 50082-1

NAME                                   :  KACHIT

SURNAME                            :  SRIMUNCHU

POSITION                             :  ENGINEERING MANAGER

               SIGNATURE                         :

1 1

Содержание MCC

Страница 1: ...MOC MOH MCC MCH MINISPLIT Floor Ceiling TECHNICAL GUIDE Cooling only and Heat Pump Systems Models MCC MOC MCH MOH 09 to 25 Infrared remote control 035 T 700049 001...

Страница 2: ...make sure that the power supply has been disconnected ELECTRICAL CONNECTIONS All electrical wiring and connections must comply with local standards Power supply cord used must not be lighter than Poly...

Страница 3: ...Nominal Current Starting Current Fuse Size Indoor Airflow high speed Indoor unit Outdoor unit V Ph Hz Ph kW A A A m h 09 09 1 0 99 4 6 21 10 490 12 12 1 1 30 6 1 28 10 580 18 18 1 1 89 8 7 43 16 700...

Страница 4: ...clearances A minimium of clearance is necessary around the units to ensure proper air circulation and easy access for maintenance Clearance required for indoor units Clearance required for outdoor uni...

Страница 5: ...urely tighten the hex bolts on both sides Disassemble the side panels and the air inlet grill as shown First open the grill then remove the side panel installation screws Slide the panel toward the to...

Страница 6: ...Pa 3 When pump down is finisned wait 15 minutes to detect potential circuit leakage Open service valves on the outdoor unit Note The expansion device is located in the outdoor unit 6 Table 2 Maximum p...

Страница 7: ...point entered on the control SYSTEM OPERATION MODE SELECTION ROOM TEMPERATURE SETTING Press the TEMP button up or down to change the setting to the desired room temperature The setting range is from 1...

Страница 8: ...ityofthebatteries and that they are in good working condition Also make sure that the controlispointeddirectlyattheairconditioningunitwhenyouareusing it that the distance is a maximum of 10 meters and...

Страница 9: ...it 9 The units are designed to operate for long periods of time with a minimum of maintenance However the following operations must be performed regularly RECOMMENDED FREQUENCY MAINTENANCE OPERATIONS...

Страница 10: ...nt kit 8 C Inlet air wet bulb temperature indo or unit CWB 10 15 20 25 30 35 20 25 30 35 40 Air intake dry bulb temperature outdoor unit CDB Capacity correction factor C1 Operating temperature range 1...

Страница 11: ...35 MSC 35 to 55 MSH 35 to 55 MKC 12 to 55 MKH 12 to 55 MAC 18 to 55 MAH 18 to 55 IS IN COMPLIANCE WITH REQUIREMENTS OF MACHINERY DIRECTIVE CEE 89 392 AS MODIFIED WITH DIRECTIVES CEE 91 368 93 44 93 6...

Страница 12: ...the unit into a suitable container using a refrigerant reclaim or recovery unit This refrigerant may then be re used if appropriate or returned to the manufacturer for disposal Under No circumstances...