background image

550.13-TG2Y (799)

2

Unitary Products Group

TABLE OF CONTENTS

DESCRIPTION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3

MODULAR DESIGN  . . . . . . . . . . . . . . . . . . . . . . . . .  3

FACTORY-MOUNTED COMPONENTS  . . . . . . . . . .  3

ACCESSORIES   . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3

GUIDE SPECIFICATIONS   . . . . . . . . . . . . . . . . . . .  20

EACH UNIT SHALL BE  . . . . . . . . . . . . . . . . . . . . . . . . . 20
EACH UNIT ENCLOSURE SHALL HAVE  . . . . . . . . . . . 20
THE DIMENSIONS OF EACH UNIT  . . . . . . . . . . . . . . . 20
THE BLOWER MOTOR SHALL   . . . . . . . . . . . . . . . . . . 20
THE EVAPORATOR COIL SHALL   . . . . . . . . . . . . . . . . 20
THE BLOWER WHEELS SHALL   . . . . . . . . . . . . . . . . . 20

LIST OF FIGURES

1

UNIT INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2

COIL CIRCUITING LIQUID LINE  . . . . . . . . . . . . . . . . . 8

3

UNIT DIMENSIONS - LEU360 & 480  . . . . . . . . . . . . . . 9

4

UNIT DIMENSIONS - LEU600  . . . . . . . . . . . . . . . . . . 10

5

HOT WATER COIL DIMENSIONS  . . . . . . . . . . . . . . . 10

6

STEAM COIL DIMENSIONS   . . . . . . . . . . . . . . . . . . . 11

7

BASE SECTION DIMENSIONS  . . . . . . . . . . . . . . . . . 11

8

BLOWER CURVE LEU360 . . . . . . . . . . . . . . . . . . . . . 15

9

BLOWER CURVE LEU480 . . . . . . . . . . . . . . . . . . . . . 17

10 BLOWER CURVE LEU600 . . . . . . . . . . . . . . . . . . . . . 19

LIST OF TABLES

1

STATIC RESISTANCES FOR UNIT ACCESSORIES  . 4

2

UNIT BLOWER MOTOR DATA  . . . . . . . . . . . . . . . . . . 5

3

UNIT DRIVE DATA   . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

4

LEU600 OVERLOAD ELEMENTS  . . . . . . . . . . . . . . . . 6

5

LEU600 STARTERS   . . . . . . . . . . . . . . . . . . . . . . . . . . 6

6

HOT WATER COIL HEATING CAPACITIES.   . . . . . . . 6

7

CAP CORRECTION & PRESS DROP VS GPM   . . . . . 7

8

STEAM COIL CAP (LEU360 ONLY)   . . . . . . . . . . . . . . 7

9

CORRECTION FACTOR FOR HIGH STEAM  . . . . . . . 7

10 UNIT DIMENSIONS - LEU 360 & 480  . . . . . . . . . . . . . 9
11 HOT WATER COIL DIMENSIONS . . . . . . . . . . . . . . . 10
12 STEAM COIL DIMENSIONS   . . . . . . . . . . . . . . . . . . . 11
13 BASE SECTIONS DIMENSIONS . . . . . . . . . . . . . . . . 11
14 PHYSICAL DATA  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
15 ELECTRICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . 13
16 L*EU360 SPLY AIR BLOWER PERF . . . . . . . . . . . . . 14
17 L*EU480 SPLY AIR BLOWER PERF . . . . . . . . . . . . . 16
18 L*EU600 SPLY AIR BLOWER PERF . . . . . . . . . . . . . 18

Содержание LEU360

Страница 1: ...ent positions and suspended in various positions The LEU600 can be position in up to 7 different arrangements and suspended also The LEU line will give you the power to condition large amounts of buil...

Страница 2: ...COIL DIMENSIONS 11 7 BASE SECTION DIMENSIONS 11 8 BLOWER CURVE LEU360 15 9 BLOWER CURVE LEU480 17 10 BLOWER CURVE LEU600 19 LIST OF TABLES 1 STATIC RESISTANCES FOR UNIT ACCESSORIES 4 2 UNIT BLOWER MO...

Страница 3: ...ther accessories to make them suitable for most applications FACTORY MOUNTED COMPONENTS PART LOAD OPERATION These evaporator blowers have multiple coils with pre piped distributors expansion valves an...

Страница 4: ...motors have inherent protection except those available for the 50 ton unit Motors for 50 ton units require a starter and overload elements DRIVE PACKAGES Different size pulleys and belts are avail ab...

Страница 5: ...cept the motors for the LEU600 These motors require external protection starter with overloads and periodic lubrication All motors have a solid base TABLE 3 UNIT DRIVE DATA UNIT MODEL DRIVE DATA BELT...

Страница 6: ...DO NOT USE STEAM IN HOT WATER Coils DO NOT OPERATE THE SUPPLY AIR BLOWER ABOVE ITS NOMINAL HP RATING WHEN A UNIT IS EQUIPPED WITH A STEAM COIL ACCESSORY ALTHOUGH THESE COILS ARE SUITABLE OF A MUCH HIG...

Страница 7: ...multiply these values by 2 31 TABLE 8 STEAM COIL CAPACITY1 LEU360 only MBH 2psig2 STEAM COIL MODEL UNIT MODEL CFM DRY BULB TEMPERATURE OF AIR ENTERING COIL F 10 30 50 70 1NF0454 LEU360 8 000 535 483...

Страница 8: ...550 13 TG2Y 799 8 Unitary Products Group FIGURE 2 COIL CIRCUITING LIQUID LINE...

Страница 9: ...LEU360 480 TABLE 10 UNIT DIMENSIONS LEU 360 480 MODEL A B C D E F G H J K M N P LEU360 100 1 8 95 5 8 33 1 4 36 5 8 73 1 4 2 1 2 18 7 8 16 1 2 15 13 16 21 7 8 22 9 16 1 2 1 8 LEU480 103 1 8 98 5 8 40...

Страница 10: ...ER COIL DIMENSIONS TABLE 11 HOT WATER COIL DIMENSIONS COIL MODEL UNIT MODEL DIMENSIONS A B C D E F 1HW0406 LEU360 100 1 8 37 7 8 6 3 4 3 7 8 1 3 8 1 3 8 1HW0407 LEU480 LEU600 103 1 8 45 1 4 6 1 2 4 1...

Страница 11: ...2 2 2 1 2 1 Coils are field installed between the evaporator coil and the blower section of the unit FIGURE 7 BASE SECTION DIMENSIONS TABLE 13 BASE SECTIONS DIMENSIONS1 1 Ventilation air can be broug...

Страница 12: ...GE LBS REFRIGERANT 22 System 1 18 12 14 System 2 12 19 DRAINABLE HOT WATER COIL ACCESSORY Tube copper OD inches 1 2 1 2 1 2 Rows Deep 2 2 2 Fins Aluminum per 1 inch 12 12 8 Face Area feet2 21 2 27 2 2...

Страница 13: ...195 40 60 460V 5 6 7 385 12 30 7 1 2 10 5 245 20 30 10 12 5 320 20 30 480 208 3 60 7 1 2 21 0 135 35 60 10 25 0 175 40 60 230 460 3 60 230V 7 1 2 21 0 150 35 60 10 25 0 195 40 60 460V 7 1 2 10 5 245 2...

Страница 14: ...1 81 9 2 7 9 1 71 10 0 8 6 1000 2 25 7 6 6 6 2 15 8 2 7 1 2 06 8 8 7 6 1 97 9 5 8 2 1 88 10 4 9 0 1 Unit resistance is based on a wet evaporator coil and clean filters 2 Available static pressure in I...

Страница 15: ...550 13 TG2Y 1001 Unitary Products Group 15 FIGURE 8 BLOWER CURVE LEU360...

Страница 16: ...22 6 8 5 9 1 08 7 8 6 7 0 93 8 8 7 6 0 76 9 8 8 4 0 55 10 8 9 3 900 1 76 8 1 7 0 1 64 9 3 8 0 1 50 10 5 9 0 9156 1 84 8 3 7 2 1 72 9 5 8 2 1 58 10 7 9 2 1 Unit resistance is based on a wet evaporator...

Страница 17: ...550 13 TG2Y 1001 Unitary Products Group 17 FIGURE 9 BLOWER CURVE LEU480...

Страница 18: ...2 50 16 0 13 8 9307 2 88 13 5 11 6 2 81 15 3 13 2 1 Unit resistance is based on a wet evaporator coil and clean filters 2 Available static pressure in IWG to overcome the resistance of the duct system...

Страница 19: ...550 13 TG2Y 1001 Unitary Products Group 19 FIGURE 10 BLOWER CURVE LEU600...

Страница 20: ...ide the rigid support required for shipping rigging and years of dependable operation Exterior panels of 18 gauge steel finished with baked enamel to provide a long lasting quality appearance Removabl...

Отзывы: