5167530-JIM-H-0218
26
Johnson Controls Unitary Products
J10
(10)
208
16.0 110.0 24.9
3.0
6.8
5.5
10.0
None
-
-
-
58.9
64.4
70
80
E18
13.5
2
37.5
67.8
74.7
70
80
E24
18.0
2
50.0
83.5
90.3
90
100
E36
25.5
2
70.8
109.5
116.4
110
125
E54
40.6
2
112.7
161.9
168.7
175
175
230
16.0 110.0 24.9
3.0
6.8
5.5
10.0
None
-
-
-
58.9
64.4
70
80
E18
18.0
2
43.3
75.1
82.0
80
90
E24
24.0
2
57.7
93.2
100.0
100
100
E36
34.0
2
81.8
123.2
130.1
125
150
E54
54.0
2
129.9
150.9
157.8
175
175
460
7.8
52.0
12.1
1.6
3.4
2.2
5.0
None
-
-
-
29.2
31.4
35
35
E18
18.0
2
21.7
37.6
40.3
40
45
E24
24.0
2
28.9
46.6
49.3
50
50
E36
34.0
2
40.9
61.6
64.4
70
70
E54
54.0
2
65.0
75.5
78.2
80
90
575
5.7
38.9
8.9
1.4
2.4
1.8
4.0
None
-
-
-
21.9
23.7
25
25
E18
18.0
2
17.3
29.7
31.9
30
35
E24
24.0
2
23.1
36.9
39.1
40
40
E36
34.0
2
32.7
48.9
51.1
50
60
E54
54.0
2
52.0
60.0
62.2
70
70
J12
(12.5)
208
23.1 160.0 36.0
2.1
9.6
5.5
10.0
None
-
-
-
80.0
85.5
100
100
E18
13.5
2
37.5
80.0
85.5
100
100
E24
18.0
2
50.0
87.0
93.8
100
100
E36
25.5
2
70.8
113.0
119.9
125
125
E54
40.6
2
112.7
165.4
172.2
175
175
230
23.1 160.0 36.0
2.1
9.6
5.5
10.0
None
-
-
-
80.0
85.5
100
100
E18
18.0
2
43.3
80.0
85.5
100
100
E24
24.0
2
57.7
96.7
103.5
100
110
E36
34.0
2
81.8
126.7
133.6
150
150
E54
54.0
2
129.9
154.4
161.3
175
175
460
12.2 87.0
19.0
1.3
4.7
2.2
5.0
None
-
-
-
42.2
44.4
50
50
E18
18.0
2
21.7
42.2
44.4
50
50
E24
24.0
2
28.9
48.2
51.0
50
60
E36
34.0
2
40.9
63.2
66.0
70
70
E54
54.0
2
65.0
77.1
79.8
90
90
575
8.7
62.0
13.5
0.7
3.6
1.8
4.0
None
-
-
-
29.8
31.6
35
40
E18
18.0
2
17.3
31.2
33.4
35
40
E24
24.0
2
23.1
38.4
40.6
40
45
E36
34.0
2
32.7
50.4
52.6
60
60
E54
54.0
2
52.0
61.5
63.7
70
70
1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.
J06 thru 12ZJ Standard Motor - With Powered Convenience Outlet (Continued)
Size
(Tons)
Volt
Compressors
(each)
OD Fan
Motors
(each)
Supply
Blower
Motor
Pwr
Exh
Motor
Pwr
Conv
Outlet
Electric Heat Option
MCA
1
(Amps)
MCA
1
w/Pwr
Exh
(Amps)
Max Fuse
2
/
Breaker
3
Size
(Amps)
Max Fuse
2
/
Breaker
3
Size w/ Pwr
Exh
(Amps)
RLA LRA MCC
FLA
FLA
FLA
FLA
Model
kW