ENGLISH
6
operation suppression zone
2 hours
Set temperature
1 hours
ECONOMIC Operation
operation
starts
1°C
2°C
Cooling
Cooling
Time
DRYING operation
Room
temperature
set temperature
Cooling
Fan only
Fan only
HOW THE AIR CONDITIONER WORKS
■
AUTOMATIC OPERATION
• When you set the air conditioner in AUTO mode, it will automatically select
cooling, heating (cooling/heating models only), or fan only operation de-
pending on what temperature you have selected and the room temperature.
• The air conditioner will control room temperature automatically round the
temperature point set by you.
• If the AUTO mode is uncomfortable, you can select desired conditions manually.
■
ECONOMIC OPERATION
When you push SLEEP button during cooling, heating (cooling only type
without),or AUTO operation, the air conditioner will start following operation.
The fan speed will be automatically controlled. In the operation suppression
zone where capacity is kept to the minimum, overcooling is prevented by raising
the temperature setting by 1°C after 1 hour and by 2°C after 2 hours of operation.
The room temperature is thus regulated between the operation suppression
zone and the set temperature. (It depends on the outdoor temperature.)
■
DRYING OPERATION
• The dry mode will automatically select the drying operation based on the
difference between the set temperature and the actual room temperature.
• The temperature is regulated while dehumidifying by repeating turning on
and off of the cooling operation or fan only. The fan speed indicator will
display AUTO and low speed will be used.
■
TEMPORARY OPERATION
This function is used to operate the unit temporarily in case you misplace the
remote controller or its batteries are exhausted.
• Set the TEMPORARY switch to the AUTO position in order to start the auto-
matic operation.
• The COOL position is provided for test runs of the unit, and automatic tem-
perature control is cut off at this position.
Never use the position for ordinary operation.
COOL
AUTO
TEMPORARY OPERATIONS
TEMPORARY and REMOTE CONTROL SWITCH
Indoor unit
OPTIMAL OPERATION
To achieve optimal performance, Please note the following:
• Adjust the air flow direction correctly so that it is not directed on people.
• Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels.
• Close doors and windows on COOL or HEAT modes, or performance may be reduced.
• Use TIMER ON button on the remote controller to select a time you want to start your air conditioner.
• Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air
conditioner may stop running.
• Clean the air filter periodically, otherwise cooling or heating performance may be reduced.
• Do not operate unit with horizontal louver in closed position.
PREPARATION BEFORE INSTALLATION
• Before doing any work, check the interior power supply cord and the main breaker capacity are sufficient and the
installation area is sufficient and complies with the requirements.
• Check that the power supply available agrees with nameplate voltage.
• Electrical work, wiring and cables must be performed in compliance with national and local wiring codes and standard.
• Do not use the extension cables. In the case extended cables are needed, use the terminal block.
J222