MANUAL OPERATION
Manual operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted.
Manual control button
Manual control button
1
Open and lift the front panel up to an angle until it remains fixed
with a clicking sound.
2
Push the button until the AUTO indicator is lit, the unit will work
in forced AUTO mode.
3
Close the panel firmly to its original position.
CAUTIONS
•
Once you push the manual button, the operation mode is shifted
in an order as: AUTO, COOL, OFF.
•
Push the manual button until the operation indicator flashes
rapidly (five times per second), the unit now operating in forced
COOL mode. This is used for testing purposes only. On forced
COOL mode, the remote operation function is unavailable.
•
When the OPERATION indicator goes off, the air conditioner is OFF.
•
To restore the remote controller operation, use the remote
controller directly.
HOW THE AIR CONDITIONER WORKS
operation suppression zone
■
AUTOMATIC OPERATION
• When you set the air conditioner in AUTO mode, it will automatically
EN
select cooling, heating (cooling/heating models only), or fan only
operation depending on what temperature you have selected and
o
p
e
ra
tio
n
st
a
rts
1
1 hours
2
Set temperature
2 hours
the room temperature.
•
The air conditioner will control room temperature automatically
round the temperature point set by you.
•
If the AUTO mode is uncomfortable, you can select desired
conditions manually.
ECONOMIC Operation
Cooling
Fan only Cooling
Fan only Cooling
Room
temperature
Time
set temperature
DRYING operation
■
ECONOMIC OPERATION
When you push ECONO button during cooling, heating (cooling only type
without),or AUTO operation, the air conditioner will start following
operation. The fan speed will be automatically controlled. In the
operation suppression zone where capacity is kept to the minimum,
overcooling is prevented by raising the temperature setting by 1°C after 1
hour and by 2°C after 2 hours of operation. The room temperature is thus
regulated between the operation suppression zone and the set
temperature. (It depends on the outdoor temperature.)
■
DRYING OPERATION
•
The dry mode will automatically select the drying operation based
on the difference between the set temperature and the actual
room temperature.
•
The temperature is regulated while dehumidifying by repeating
turning on and off of the cooling operation or fan only. The fan
speed indicator will display AUTO and low speed will be used.
ENGLISH
5
J174_lastRev4.pmd
5