036-21215-003 Rev. B (1202)
4
Unitary Products Group
- = Not applicable
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
3
EER
TOTAL SENS.
1 PH 12 SEER AC WITH N1AH / G2FD
H4AH024S06
N1AHB0806
2,5,8,10
17
G2FD024(S,H)17
850
24.0
18.0
12.00
-
10.80
H4AH024S06
N1AHB0806
2,5,8,10
17
G2FD030(S,H)17
850
24.2
18.3
12.00
-
10.70
H4AH030S06
N1AHB1206
5,8,10,15,19
17
G2FD030(S,H)17
1060
28.8
21.5
11.50
-
10.25
H4AH030S06
N1AHB1206
5,8,10,15,19
17
G2FD036(S,H)17
1060
30.2
22.6
12.00
-
10.50
H4AH036S06
N1AHB1206
5,8,10,15,19
17
G2FD036(S,H)17
1250
36.0
27.0
12.00
-
10.85
H4AH036S06
N1AHB1206
5,8,10,15,19
17
G2FD046(S,H)17
1250
35.6
26.8
12.00
-
10.90
H4AH036S06
N1AHD1406
5,8,10,15
24
G2FD048(S,H)24
1250
36.8
27.7
12.20
-
11.20
H4AH042S06
N1AHC1606
5,8,10,15,20
21
G2FD042(S,H)21
1350
40.5
30.0
12.00
-
11.00
H4AH042S06
N1AHC1606
5,8,10,15,20
21
G2FD048(S,H)21
1350
41.5
31.0
12.30
-
11.40
H4AH048S06
N1AHC1606
5,8,10,15,20
21
G2FD048(S,H)21
1620
48.0
35.3
12.20
-
11.30
H4AH048S06
N1AHD2006
8,10,15,20,25,30
24
G2FD060(S,H)24
1620
48.0
35.3
12.30
-
11.30
H4AH060S06
N1AHD2006
8,10,15,20,25,30
24
G2FD060(S,H)24
1850
59.0
43.4
12.00
-
10.50
H4AH060S06
N1AHD2006
8,10,15,20,25,30
24
G2FD061H24
1850
59.5
45.0
12.10
-
10.65
1 PH 12 SEER AC / N1VS - VARIABLE SPEED
H4AH024S06
N1VSB12
10,15,18
17
G2FD024(S,H)17
820
24.6
18.4
13.00
-
12.00
H4AH024S06
N1VSB12
10,15,18
17
G2FD036(S,H)17
820
24.6
18.7
13.00
-
12.20
H4AH030S06
N1VSB12
10,15,18
17
G2FD030(S,H)17
1035
29.2
22.0
12.30
-
11.30
H4AH030S06
N1VSB12
10,15,18
17
G2FD036(S,H)17
1070
30.8
23.3
13.00
-
11.40
H4AH036S06
N1VSB12
10,15,18
17
G2FD036(S,H)17
1250
36.4
27.1
12.60
-
11.40
H4AH036S06
N1VSB12
10,15,18
17
G2FD046(S,H)17
1230
36.0
27.3
12.50
-
11.50
H4AH036S06
N1VSC16
10,15,18
21
G2FD048(S,H)21
1220
37.4
28.3
13.50
-
12.10
H4AH042S06
N1VSC16
10,15,18
21
G2FD042(S,H)21
1350
41.0
30.6
13.00
-
11.80
H4AH042S06
N1VSC16
10,15,18
21
G2FD048(S,H)21
1350
42.0
31.3
13.30
-
12.20
H4AH048S06
N1VSC16
10,15,18
21
G2FD048(S,H)21
1590
48.5
36.1
12.90
-
11.90
H4AH048S06
N1VSD20
10,15,18,30
24
G2FD060(S,H)24
1600
48.0
36.1
13.00
-
11.85
H4AH060S06
N1VSD20
10,15,18,30
24
G2FD060(S,H)24
1600
58.5
44.5
12.55
-
10.90
H4AH060S06
N1VSD20
10,15,18,30
24
G2FD061H24
1600
59.0
45.7
12.65
-
11.10
1 PH 12 SEER AC / F2RP / RC / FP / FC / FV
4,5
H4AH024S06
F2RC/FC030
5,8,10,15
18
-
850
23.2
16.7
11.70
-
10.60
H4AH024S06
F2RP/FP024
5,8,10
18
-
850
24.0
18.0
12.00
-
10.80
H4AH024S06
F2RP/FP030
5,8,10,15
18
-
850
24.6
18.6
12.00
-
10.75
H4AH030S06
F2RC/FC036
5,8,10,15
21
-
1060
28.8
21.5
11.50
-
10.25
H4AH030S06
F2RP/FP030
5,8,10,15
18
-
1060
28.8
21.5
11.50
-
10.30
H4AH030S06
F2RP/FP036
5,8,10,15,19
18
-
1060
29.6
22.1
11.50
-
10.40
H4AH036S06
F2RP/FP036
5,8,10,15,19
21
-
1250
35.4
26.6
11.90
-
10.80
H4AH036S06
F2RP/FP042
5,8,10,15
21
-
1250
35.4
26.6
11.80
-
10.70
H4AH036S06
F2FP048
5,8,10,15,20,25
24
-
1250
36.6
27.5
12.00
-
10.90
H4AH042S06
F2RP/FP042
5,8,10,15
21
-
1350
40.5
30.0
12.00
-
10.90
H4AH042S06
F2FP045
5,8,10,15
24
-
1350
41.5
31.0
12.30
-
11.40
H4AH042S06
F2FP048
5,8,10,15,20,25
24
-
1350
41.0
30.6
12.00
-
11.20
H4AH042S06
F2FV060
8,10,15,20,25
24
-
1350
42.0
31.7
14.00
-
12.25
H4AH048S06
F2FP048
5,8,10,15,20,25
24
-
1620
47.5
34.9
12.00
-
11.00
H4AH048S06
F2FP060
5,8,10,15,20,25
24
-
1620
47.5
34.9
12.00
-
10.80
H4AH048S06
F2FV060
8,10,15,20,25
24
-
1605
48.5
36.1
13.50
-
12.50
H4AH060S06
F2FP060
5,8,10,15,20,25
24
-
1850
59.0
43.4
11.50
-
10.10
H4AH060S06
F2FV060
8,10,15,20,25
24
-
1860
60.5
44.5
13.00
-
11.50
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
0
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input
in watt-hours during the same period.
1
G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2
Single phase units require single phase 2HK heaters.
3
TXV = Use 1TV700 Series Kit.
4
To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
.
models. All ratings remain the same.
5
FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.