Johnson Controls Unitary Products

277805-YTG-A-1106

For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at
www.upgnet.com in the Product Catalog Section.

Thermostat Chart

AC1

Single Stage A/C w/Single Stage Furnace, 1 Stage Cooling Ready - (G,L)*8/9S, XYF80-U, XYF80-U*L, XYF90-U

HM1

Humidistat

Thermostat Installer Setup Number 1 - 

System Type - must be set to 0

Selection of GAS/ELEC switch 

on thermostat not necessary

Thermostat Installer Setup Number 15 - 

Compressor Protection - must be set to 5

24V HUMIDIFIER

G

Fan

G

Fan

G

Fan

G

Fan

W

First Stage Heat

W

First Stage Heat

W

First Stage Heat

W

Single Stage Heat

RC

24-Volt Hot (Cool XFMR)

RC

24-Volt Hot (Cool XFMR)

RC

24-Volt Hot (Cool XFMR)

R

24-Volt Hot (Heat XFMR)

RH

24-Volt Hot (Heat XFMR)

RH

24-Volt Hot (Heat XFMR)

R

24-Volt Hot

C

24-Volt Common

C

24-Volt Common

Y

First Stage Cool

Y

First Stage Cool

Y

First Stage Cool

Y/Y2

Single/Second Stage Cool

Y

Single Stage Cool

*DN11C00124

C

24-Volt Common

C

24-Volt Common

Optional w/Batteries

*BN11C01124

*DP11C40124

PSC

FURNACE CONTROL

SINGLE STAGE

AIR CONDITIONING

*BN11C00124

*BP11C50124

*PP11C70224

THERMOSTAT

THERMOSTAT

THERMOSTAT

HP1

W/031-01975- Series Demand Control

Single Stage H/P - E*RD, E*BD, ERHS, HPX13 - w/Single Stage Furnace, 1 Stage Cooling Ready - (G,L)*8/9S, XYF80-U, XYF80-U*L, XY

F90-U

SINGLE STAGE

HEAT PUMP

*DN22U00124

*BP21H50124

*PP32H70124

THERMOSTAT

THERMOSTAT

THERMOSTAT

PSC

FURNACE CONTROL

*BN21H00124

*DP21H40124

*DN21H00124

N/A

N/A

C

24-Volt Common

R

24-Volt Hot

E

Emergency Heat

O

Reversing Valve–Energized in Cool

C

24-Volt Common

C

24-Volt Common

Y

First Stage Heat/Cool

Y/Y2

Single/Second Stage Cool

Y

Single Stage Heat/Cool

R

24-Volt Hot

R

24-Volt Hot

W1

Second Stage Heat

W

Single Stage Heat

W1/66

First Stage Heat Out

G

Fan

G

Fan

W

First Stage Heat

Step 1 of Thermostat User Configuration Menu 

must be set to Heat Pump 1

Step 9 of Thermostat User Configuration Menu 

must be set to Pump OFF

O

Reversing Valve–Energized in Cool

L

Malfunction Light

X/L

Malfunction Light

Содержание GY9S-UP

Страница 1: ...aser 10 year warranty on the heat exchanger in commercial appli cations 5 year limited parts warranty FEATURES Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improve...

Страница 2: ...MAGE RETURN END TOP IMAGE SUPPLY END 1 1 2 GAS PIPE ENTRY 7 8 JUNCTION BOX HOLE T STAT WIRING 7 8 K O CONDENSATE DRAIN 7 8 K O Models Nominal CFM Cabinet Size Cabinet Dimension A in B in C in D in GY9...

Страница 3: ...12UP11 60 B 56 1200 17 1 2 9 92 0 40 70 GY9S080B12UP11 80 B 74 1200 17 1 2 9 92 0 45 75 GY9S080C16UP11 80 C 75 1600 21 12 92 0 45 75 GY9S080C20UP11 80 C 75 2000 21 14 92 0 40 70 GY9S100C16UP11 100 C 9...

Страница 4: ...680 1595 1500 1390 1270 1155 M LO 1610 1545 1490 1440 1390 1315 1230 1155 1050 920 LOW 1325 1270 1225 1175 1105 1045 990 905 890 790 GY9S080C16UP11 GY9S100C16UP11 HIGH 1960 1955 1925 1890 1830 1765 16...

Страница 5: ...ers 2 Air flows above 1800 CFM require either return from two sides or one side plus bottom RECOMMENDED FILTER SIZES Nominal CFM Cabinet Size Side Return Filter in Bottom Return Filter in cm 1200 A 16...

Страница 6: ...tage Cool Y Y2 Single Second Stage Cool Y Single Stage Cool DN11C00124 C 24 Volt Common C 24 Volt Common Optional w Batteries BN11C01124 DP11C40124 PSC FURNACE CONTROL SINGLE STAGE AIR CONDITIONING BN...

Страница 7: ...ACCESSORIES PROPANE LP CONVERSION KIT 1NP0347 All Models This accessory conversion kit may be used to convert natural gas units for propane LP operation Conversions must be made by qualified distribut...

Страница 8: ...change without notice Printed in U S A 277805 YTG A 1106 Copyright by York International Corp 2006 All rights reserved Supersedes 246716 YTG B 0806 Unitary 5005 Norman Products York OK Group Drive 73...

Отзывы: