FORM 100.50-EG3 (802)
39
YORK INTERNATIONAL
TABLE 16 –
90 THROUGH 95 TON SUPPLY FAN DATA (CONT’D)
TOTAL STATIC PRESSURE (Pascals of water column)
m3/hr
871
995
1120
1244
1369
STD. AIR
kW
RPM
kW
RPM
kW
RPM
kW
RPM
kW
RPM
30582
15.4
739
17.6
795
33980
16.6
717
18.7
776
22.2
841
24.5
899
37378
16.8
695
19.8
756
23.3
821
26.7
880
29.6
930
40776
18.7
697
21.3
749
24.3
804
27.5
856
3.7
907
44174
2.7
698
23.0
742
25.5
786
28.4
832
31.8
884
47572
23.2
705
25.6
748
28.2
789
3.9
832
34.5
877
50970
25.7
711
28.3
753
3.9
792
33.5
831
36.3
869
53519
27.2
715
29.8
757
32.6
796
35.2
834
38.2
872
54368
28.7
719
31.4
760
34.2
799
36.9
838
39.8
874
57766
31.6
727
34.6
767
37.5
806
4.4
844
43.3
879
61164
46.9
737
6.0
776
55.6
814
59.2
850
TABLE 16 –
90 THROUGH 95 TON SUPPLY FAN DATA
TOTAL STATIC PRESSURE (Pascals of water column)
m3/hr
245
373
498
622
747
STD. AIR
kW
RPM
kW
RPM
kW
RPM
kW
RPM
kW
RPM
30582
6.3
460
7.9
524
9.9
591
12.6
670
33980
7.5
468
9.2
530
11.2
591
13.6
656
37378
8.7
475
1.6
535
12.5
590
14.5
641
40776
8.2
425
1.2
486
12.3
543
14.3
597
16.4
647
44174
9.6
438
11.8
497
13.9
551
16.2
603
18.4
652
47572
11.4
453
13.8
461
16.4
563
18.4
612
2.7
659
50970
13.2
467
15.6
424
18.1
574
2.6
621
23.9
666
53519
14.2
475
16.8
456
19.4
581
21.9
627
24.5
671
54368
15.4
483
17.9
488
2.7
587
23.3
633
25.9
676
57766
17.7
499
2.3
551
23.2
600
26.6
644
28.8
686
61164
2.3
515
23.1
556
26.2
614
29.6
657
32.6
698