036-21001-005 Rev. C (0505)
2
Unitary Products Group
Physical and Electrical Data - 1 Phase
MODEL
DRCS0181BE DRCS0241BE DRCS0301BE DRCS0361BE DRCS0421BE DRCS0481BE DRCS0601BF
Unit Supply Voltage
208/230 – 1 – 60
Normal Voltage Range
187 to 252
Minimum Circuit Ampacity
1
10.1
14.1
16.5
19.7
26.2
28.5
37.5
Max. Overcurrent Device Amps
2
15
25
25
30
45
50
60
Compressor Type
3
Recip
Inertia
Recip
Recip
Scroll
B
Recip
Scroll
B
Compressor Amps
Rated Load
7.7
10.9
12.8
14.7
19.9
21.8
28.8
Locked Rotor
48
60
68
82
115
105
145
Crankcase Heater
No
No
No
Yes
No
No
No
Fan Motor Amps
Rated Load
0.5
0.5
0.5
1.3
1.3
1.3
1.5
Fan Diameter Inches
18
18
22
22
22
22
22
Fan Motor
Rated HP
1/12
1/12
1/15
1/4
1/4
1/4
1/4
Nominal RPM
1,100
1,100
850
850
850
850
850
Nominal CFM
2,000
2,000
2,300
3,300
3,300
3,300
3,450
Coil
Face Area Sq. Ft.
12.58
12.58
15.72
15.72
17.03
19.65
23.58
Rows Deep
1
1
1
1
1
1
1
Fin / Inches
18
18
18
18
18
18
22
Liquid Line OD
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line OD
3/4
3/4
3/4
3/4
7/8
7/8
1-1/8
Unit Charge (Lbs. - Oz.)
4
4 - 9
4 - 7
5 - 8
5 - 3
6 - 13
7 - 7
8 - 15
Charge Per Foot, Oz.
0.68
0.68
0.68
0.68
0.70
0.70
0.76
Operating Weight Lbs.
144
146
156
161
157
190
198
PHYSICAL AND ELECTRICAL DATA - 3 Phase
MODEL
HABC-T036S HABC-T048S HABC-T060S
HABC-W036S HABC-W048S HABC-W060S
Unit Supply Voltage
208/230 – 3 – 60
460 - 3 - 60
Normal Voltage Range
1
187 to 252
432 to 504
Minimum Circuit Ampacity
13.3
18.9
22.9
7.6
9.6
12.0
Max. Overcurrent Device Amps
2
20
30
40
15
15
20
Compressor Type
Inertia
Inertia
Scroll
Inertia
Inertia
Scroll
Compressor Amps
Rated Load
9.6
14.1
17.3
5.4
7.0
9.0
Locked Rotor
78.0
130.0
123.0
40.0
64.0
62.0
Crankcase Heater
No
No
No
No
No
No
Fan Motor Amps
Rated Load
1.3
1.3
1.3
0.8
0.8
0.8
Fan Diameter Inches
22
22
22
22
22
22
Fan Motor
Rated HP
1/4
1/4
1/4
1/4
1/4
1/4
Nominal RPM
850
850
850
850
850
850
Nominal CFM
3,300
3,300
3,400
3,300
3,300
3,400
Coil
Face Area Sq. Ft.
15.72
17.03
23.58
15.72
17.03
23.58
Rows Deep
1
1
1
1
1
1
Fin / Inches
18
18
18
18
18
18
Liquid Line OD
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line OD
3/4
7/8
1-1/8
3/4
7/8
1-1/8
Unit Charge (Lbs. - Oz.)
4
6 - 2
7 - 10
9 - 3
6 - 2
7 - 10
9 - 3
Charge Per Foot, Oz.
0.68
0.70
0.76
0.68
0.70
0.76
Operating Weight Lbs.
157
184
198
157
184
198
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker.
3. All scrolls listed with a superscript “B” are Bristol scrolls. All scrolls listed with a superscript “C” are Copeland scrolls.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or sub-
tract the amount of refrigerant, using the difference in length multiplied by the per foot value.