FIGURE 31:
Horizontal Left Configuration
HORIZONT
AL
- LEFT
INDUCER ROT
A
TED
HORIZONT
AL
- LEFT
INDUCER
AS RECEIVED
AIRFLOW
AIRFLOW
Move pressure switch hose
to this position.
NOTE: May require the longer
hose that is provided with
wider cabinets
Move rain gutter hose to this position
NOTE: May require hose extension
that is provided with wider cabinets
Move rain gutter
hose to this position
Move pressure switch
hose to this position.
NOTE: May require
the longer hose that
is provided with
wider cabinets
Change condensate drain
connection to the 90° fitting provided
Move condensate
drain hose to this position
Move rain gutter
hose to this position.
NOTE: May require
hose extension that is
provided with wider
cabinets
Move
condensate
drain hose to
this position
Change condensate
drain connection to
the 90° fitting provided
When drain hose routing changes are required, be sure to cap all un-used openings.
If rerouting hoses - excess length should be cut of
f so that no sagging loops will collect
and hold condensate, which will cause the furnace to not operate.