036-21489-001-C-1004
Unitary Products Group
13
•
SMOKE DETECTORS
- (supply air & return air) The
smoke detectors stop operation of the unit by interrupting
power to the control board if smoke is detected within the
air compartment.
•
COIL GUARD
- Customers can purchase a coil guard kit
to protect the condenser coil from damage. This is not a
hail guard kit.
•
STAINLESS STEEL DRAIN PAN-
An optional rust-proof
stainless steel drain pan is available to provide years of
trouble-free operation in corrosive environments.
•
PHASE MONITORS
- Designed to prevent unit damage.
The phase monitor will shut the unit down in an out-of-
phase condition.
•
HIGH SPEED DRIVE
- Includes a belt and blower pulley
upgrade to enhance blower performance.
•
DIRTY FILTER SWITCH
- This kit includes a differential
pressure switch that energizes the fault light on the unit
thermostat, indicating that there is an abnormally high
pressure drop across the filters. Factory installed option
or field installed accessory.
•
HINGED FILTER DOOR/”TOOLLESS” BLOWER AND
ACCESS PANELS (not hinged)
- This option allows for
easy access and maintenance.
NOTE: Knobs are shipped separately within the unit to
prevent shipping damage. These must be field
installed for tool-less operation.
FIELD-INSTALLED ACCESSORIES
•
SINGLE INPUT ELECTRONIC ENTHALPY ECONO-
MIZERS
- Includes a slide-in / plug-in damper assembly
with fully modulating spring-return motor actuator capa-
ble of introducing up to 100% outdoor air with nominal
1% leakage type dampers.
The enthalpy system contains one sensor that monitors
the outdoor air and determines when the air is cool
enough and dry enough to provide free cooling.
The rainhood is painted to match the basic unit and must
be field-assembled before installing.
Power exhaust is not available as a field installed option.
•
MOTORIZED OUTDOOR AIR INTAKE DAMPER
-
Includes a slide-in / plug-in damper assembly with a 2-
position, spring return motor actuator which opens to
some pre-set position whenever the supply air blower is
operating and will drive fully closed when the blower unit
shuts down.
The rain hood is painted to match the basic unit and
must be field assembled before installing.
Power exhaust is not available as a field installed option.
•
ROOF CURBS
- Fourteen-inch high roof curbs provide a
water-tight seal between the unit and the finished roof.
These full perimeter curbs meet the requirements of the
National Roofing Contractors Association (NRCA) and
are shipped knocked-down for field assembly.
They're designed to fit inside the base rails of the unit
and include both a wood nailing strip and duct hanger
supports.
•
SIDE DUCT FLANGES
- One-inch flanges replace the
supply and return air panels on the rear of the unit to
accommodate horizontal duct connections. These
flanges can also be used individually for bottom supply/
horizontal return or horizontal supply/bottom return. They
cannot be used on units with power exhaust.
•
BAROMETRIC RELIEF DAMPER
- This damper acces-
sory can be used to relieve internal building air pressure
on units with an economizer without power exhaust. This
accessory includes a rain hood, a bird screen and a fully
assembled damper. With bottom duct connections, the
damper should be mounted over the opening in the
return air panel. With horizontal ductwork, the accessory
should be mounted on the return air duct.
•
HIGH SPEED DRIVE
- A smaller blower pulley and a
shorter belt increase the speed of the supply air blower
for applications with a higher CFM and/or static pressure
requirements.
•
ENTHALPY ACCESSORY CONTROL KIT
- This kit
contains the required components to convert a single
enthalpy economizer to dual enthalpy.
•
BURGLAR BARS
- Mount in the supply and return
openings to prevent entry into the duct work.
•
WOOD SKID
- Allows unit to be handled with 90” forks.
•
CO
2
SENSOR
- Senses CO
2
levels and automatically
overrides the economizer when levels rise above the
present limits.
•
COIL GUARD
- Customers can purchase a coil guard kit
to protect the condenser coil from damage. This is not a
hail guard kit.
•
PHASE MONITORS
- Designed to prevent unit damage.
The phase monitor will shut the unit down in an out-of-
phase condition.