background image

036-21581-001 Rev. B (0904)

2

Unitary Products Group

.

Three elbows (two in vent pipe and one in the air intake pipe) are already accounted for and need not be included in the elbow count from the Table 
above.

 

30-7/8

21-1/2

13-7/8

7

11

7/8

23-3/4

7/8

30-1/8

26-1/2

24-5/8

A

40

26-1/2

25-3/8

28-3/8

21-1/2

11

8

26-3/4

1-3/8

1-1/4

C

24-3/8

20

5/8

5/8

B

26-1/2

1-3/4

D

1-1/2” GAS
PIPE ENTRY

7/8” JUNCTION
BOX HOLE

T-STAT WIRING
7/8” K.O.

CONDENSAATE
DRAIN 7/8” K.O.

OPTIONAL RETURN AIR
CUT-OUT (either side)
FOR USE WITH
EXTERNAL FILTER
FRAME

LEFT SIDE

FRONT

RIGHT SIDE

BOTTOM IMAGE

RETURN END

TOP IMAGE

SUPPLY END

1-1/2” GAS
PIPE ENTRY

7/8” JUNCTION
BOX HOLE

T-STAT WIRING
7/8” K.O.

CONDENSAATE
DRAIN 7/8” K.O.

DIMENSIONS

BTUH

Input/Output

CFM

Cabinet

Size

Cabinet Dimension

A (in.)

B (in.)

C (in.)

D (in.)

PT9A12N040UP11

1200

A

14-1/2

13-1/4

12-1/8

6-1/4

PT9B12N060UP11

1200

B

17-1/2

16-1/4

15-1/8

8-1/2

PT9B12N080UP11

1200

B

17-1/2

16-1/4

15-1/8

8-1/2

PT9C16N080UP11

1600

C

21

19-3/4

18-1/2

8-7/8

PT9C16N100UP11

1600

C

21

19-3/4

18-1/2

8-7/8

PT9C20N100UP11

2000

C

21

19-3/4

18-1/2

8-7/8

PT9D20N120UP11

2000

D

24-1/2

23-1/4

21-7/8

10-5/8

COMBUSTION AIR SUPPLY AND VENT PIPING

MAXIMUM ELBOWS AND VENT LENGTHS

Models Input 

BTUH

Pipe Size 

Inches

Maximum Number of Elbows* 

Minimum 

Length

1 2 3 4 5 6 7 8 

40,000

1-1/2

30

25

20

10

N/A

N/A

N/A

N/A

5

40,000

2

70

65

60

55

50

45

35

25

5

60,000

1-1/2

30 25 20 10 N/A 

N/A 

N/A 

N/A 

60,000

2

60 55 50 45 40 30 20 10 

60,000

3

85 80 75 70 65 60 50 40 

20 

80,000

1-1/2

20  15  N/A N/A N/A N/A N/A N/A 

80,000

60 55 50 45 40 30 20 10 

80,000

85 80 75 70 65 60 50 40 

20 

100,000

2

25  20  15  N/A N/A N/A N/A N/A 

100,000

3

85 80 75 70 65 60 50 40 

20 

120,000

3

75 70 65 60 55 45 35 25 

Содержание AFFINITY PT9

Страница 1: ...ludes Two stage gas valve Two stage inducer operation Provides increased comfort level very quiet unit oper ation Adjustable delay timer allows two stage operation with single stage thermostat Compact...

Страница 2: ...mension A in B in C in D in PT9A12N040UP11 1200 A 14 1 2 13 1 4 12 1 8 6 1 4 PT9B12N060UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PT9B12N080UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PT9C16N080UP11 1600 C 21...

Страница 3: ...1PS0503 PT9C20N100UP11 1PS0505 PT9D20N120UP11 1PS0503 ELECTRICAL AND PERFORMANCE DATA Model Input High Low Output High Low Nominal Airflow AFUE Air Temp Rise Max Outlet Air Temp Blower Blower Size Tot...

Страница 4: ...280 1245 1190 1070 LOW 930 945 965 975 975 975 975 950 910 850 PT9D20N120UP11 HIGH 2560 2485 2410 2320 2220 2135 2035 1920 1785 1650 M HI 2090 2050 1990 1970 1885 1820 1760 1675 1545 1405 M LO 1695 16...

Страница 5: ...al system static falls between ESP values in the table i e 0 58 0 75 etc the static pressure may be rounded to the nearest value in the table determining the airflow using Step 5 or calculate the airf...

Страница 6: ...e bottom of the furnace 1BR0314 For 14 1 2 cabinets 1BR0317 For 17 1 2 cabinets 1BR0321 For 21 cabinets 1BR0324 For 24 1 2 cabinets HIGH ALTITUDE PRESSURE SWITCHES These accessory kits may be used to...

Страница 7: ...036 21581 001 Rev B 0904 Unitary Products Group 7 NOTES...

Страница 8: ...without notice Printed in U S A 036 21581 001 Rev B 0904 Copyright by York International Corp 2004 All rights reserved Supersedes 036 21581 001 Rev A 0904 Unitary 5005 Norman Products York OK Group D...