![York AFFINITY CZH024 THRU 060 Скачать руководство пользователя страница 15](http://html2.mh-extra.com/html/york/affinity-czh024-thru-060/affinity-czh024-thru-060_technical-manualbook_3701592015.webp)
561926-YTG-A-0410
Johnson Controls Unitary Products
15
ACCESSORIES*
Hard Start Kit (024-31994-000, 024-31995-000) -
Provides
increased starting torque for areas with low voltage.
TXV Kits -
1TVM9 series thermal expansion valves precisely
meter refrigerant for optimum performance
Dehumidistat (2HU16700124) -
Provides increased dehumidi-
fication when matched with variable speed furnace or air han-
dler.
Thermostats
- Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.
SOUND POWER RATINGS*
* Rated in accordance with ARI 270-95 Standards.
UNIT MODEL
(dBA)
024
71
036
73
048
72
060
74