036-21335-002-A-1102
10
Unitary Products Group
NOTE: Steam Rate = (lbs/Hr.) = 1.025 x MBH
TABLE 10: STEAM COIL CAPACITIES
1
, MBH @ 2 PSIG
2
UNIT
MODEL
STEAM COIL
MODEL
CFM
DRY BULB TEMPERATURE OF AIR ENTERING COIL (°F)
10
30
50
70
LA300
1NF0454
6,000
471
424
380
330
8,000
535
483
432
380
10,000
592
535
478
422
12,000
642
580
518
456
LB360
8,000
535
483
432
380
10,000
592
535
478
422
12,000
642
580
518
456
14,000
687
621
555
489
1.
These capacities do not include any blower motor heat.
2.
Multiply these capacities by the factors in Table 11 to correct for higher steam pressure.
TABLE 11: CORRECTION FACTORS FOR HIGH STEAM
STEAM PRESSURE (PSIG)
5
10
15
20
25
CAPACITY CORRECTION FACTOR
1.05
1.12
1.19
1.25
1.30