C o m m o n f a u l t s a n d s o l u t i o n s
Problem
and code
Reason
Solution
System not
working
The power is not connected or
turned on
Plug in or switch the power to the "ON" position
safety key is not placed in the
right position
Replace the safety key
The inverter is not plugged in
the right position or the inverter
inferior
Check and connect the inverter correctly or replace it
Open circuit
Check system input and output and communication wires
Stops
suddenly
under
normal
conditions
Safety key hasfallen off
Put the safety key back to the correct place
System abnormal
Ask technician to repair it
Keyboard
not
functioning
Broken keys
1. Change the keyboard and wire;
2. Change the panel;
3. Change the console
E-01
The communication wire is bad
contact
1. Check whether the wire connects correctly;
2. Change the wire
Console defective
Change the console
Inverter defective
Change the inverter
Controller defective
Change controller
E-02
Motor wire and motor defective Change the motor
1. Bad connection between
motor connection wire and
controller;
1. Controller defective
Check and connect the wire again or change the controller.
E-03
Incorrect installation of
photoelectric inductor
Check and install again
Photoelectric inductor defective Change photoelectric inductor
Bad connection between
photoelectric inductor and
controller
Check and reconnect
Controller defective
Change the controller
E-05
Controller is damaged
Change the controller
Motor is damaged
Change the motor
E-07
No safety key signal
1.Check whether the safety is in right position
2.Change the console