background image

18

Schedule 1: Error Code Definition

YL-01, YL-02 Error codes

Error code

Definition

Error code

Definition

E001

Controller failure

E004

Throttle failure

E002

Communication failure

breakdown

E005

Brake failure

E003

Hall failure

E006

Motor phase failure

YL-05, KDS, YL-J Error codes

Error code

Definition

Error code

Definition

E021

Current failure

E024

Hall failure

E022

Throttle failure

E025

Brake failure

E023

Motor phase failure

E030

Communication failure

breakdown

Schedule 2: Pedal assist level default ratio value

Level

Level

selection

1

2

3

4

5

6

7

8

9

0-3/1-3

50% 74%

92%

-

-

-

-

-

-

0-5/ 1-5

50%

61%

73%

85%

96%

-

-

-

-

0-7/ 1-7

40%

50%

60%

70%

80%

90%

96%

-

-

0-9/ 1-9

25%

34%

43%

52%

61%

70%

79%

88%

96%

Tel: 022-86838795 Fax: 022-86838795
Email: [email protected]
Website: www.yolintech.com
Address: Tianjin Beichen District, Tianjin Beichen Economic Development Zone, Medical Equipment Industrial Park, East of
Jingfu Highway, Ugu New Science Park 52-1 plant

Содержание YL90V-V

Страница 1: ...Tianjin Yolin Technology Ltd Electric Bike Display User s Manual YL90V V...

Страница 2: ...ETTING 7 6 2 RATED VOLTAGE SETTING 7 6 3 PAS LEVEL SETTING 8 6 3 1 PAS LEVEL RATIO VALUE SETTING 8 6 4 WHEEL DIAMETER SETTING 9 6 5 NUMBER OF SPEED SENSOR MAGNETS SETTING 9 6 6 SPEED LIMIT SETTING 10...

Страница 3: ...9 WIRE CONNECTION DIAGRAM 17 9 1 STANDARD WIRE CONNECTION SEQUENCE 17 10 PRECAUTIONS 17 SCHEDULE 1 ERROR CODE DEFINITION 18 SCHEDULE 2 PEDAL ASSIST LEVEL DEFAULT RATIO VALUE 18...

Страница 4: ...ecification 36V 48V 52V power supply Display rated current 15mA Display maximum current 30mA Shutdown leakage current 1uA Supplied current to the controller 50mA Operating temperature 20 60 Storage te...

Страница 5: ...2 K5 K6 Figure 3 2 Physical picture of the 90V control button Figure 3 3 90V Front View Dimension Figure 3 4 90V Side View Dimension...

Страница 6: ...iameter speed limit battery power setting and PAS parameter setting password setting controller current limit setting etc Factory default parameter recovery function 4 2 Functional areas Figure 4 1 YL...

Страница 7: ...not used for more than 10 minutes 5 2 Display interface switching When the display is powered on it will show the Current Speed km h and Odometer km by default Short press to switch between Odometer...

Страница 8: ...g to implement the display screen The walk boost mode can only be used when pushing the electric bicycle please do not use it while riding 5 4 Turning on off lights Press the to make the controller tu...

Страница 9: ...play Interface 5 7 Error code display If there is a fault occurs in the electronic system of the electric bicycle the display will automatically show an error code see Schedule 1 for a detailed defini...

Страница 10: ...g interface The following options are available on the personalized parameter setting interface 6 1 Metric and Imperial setting P1 is the metric and imperial setting 00 for metric and 01 for imperial...

Страница 11: ...erface 6 3 1 PAS level ratio value setting To meet different requirements for users the speed of every level can be adjusted by setting the PAS level ratio value Please see the details from Schedule 2...

Страница 12: ...g interface Figure 6 5 Wheel diameter setting interface 6 5 Number of speed sensor magnets setting P5 is the speed sensor magnet number setting The adjustable speed sensor magnet number range is 1 15...

Страница 13: ...save the parameter setting and return to the personalized parameter setting interface Figure 6 7 Speed limit setting interface 6 7 Controller current Limit Setting P7 is the controller current limit s...

Страница 14: ...eter setting and enter into 6 8 2 PAS sensor sensitivity setting interface Figure 6 9 PAS sensor direction setting interface 6 8 2 PAS sensor sensitivity setting SCN is the PAS sensor sensitivity sett...

Страница 15: ...sensor magnets setting PR5 is the pedal assist sensor magnets setting The adjustable range is 5 31 Press the to select the parameter and press to save the parameter setting and to return to the perso...

Страница 16: ...and press to save the parameter setting and enter into 6 9 2 Throttle Level setting interface or long press to return to the personalized parameter setting interface Figure 6 12 Throttle 6KM H walk bo...

Страница 17: ...se keep the password in mind after changing it otherwise you will not be able to use the display Press to enter the parameter changing state Press the to select the parameter PSd y means the power on...

Страница 18: ...word setting interface 6 11 Auto Sleep Time Setting Pb is the auto sleep time setting To save the battery power and reach higher range this display will be turned off after it has not been used for a...

Страница 19: ...conds and then automatically start to restore the factory default settings The display will automatically exit to setting interface after the restoration Figure 7 1 Restore Factory Default Settings In...

Страница 20: ...9 1 Wire Connection Diagram Table 9 1 Standard connector wire sequence table Standard Wire Sequence Standard wire color Function 1 Red VCC Display power wire 2 Blue Kp Controller power wire 3 Black GN...

Страница 21: ...ilure E022 Throttle failure E025 Brake failure E023 Motor phase failure E030 Communication failure breakdown Schedule 2 Pedal assist level default ratio value Level Level selection 1 2 3 4 5 6 7 8 9 0...

Отзывы: