5

Table 7-1 Wiring Sequence of Standard Connector

Standard wiring

sequence

Standard wire color

Function

1

Red (VCC)

Power cord of display

2

Blue (Kp)

Power control line of controller

3

Black (GND)

Ground wire of display

4

Green (RX)

Data receiving line of display

5

Yellow (TX)

Data transmission line of display

The outgoing lines of some products adopt waterproof connectors, and users cannot see the outgoing line color inside the

wire harnesses.

8. Considerations

Please use safely, and do not plug or unplug the display when it is powered on.

Please avoid bumping as far as possible.

Please do not alter the background parameter settings of the display at will, otherwise normal riding cannot be

guaranteed.

If the display fails to work normally, it should be repaired as soon as possible.

Due to product upgrades of the Company, part of the displayed contents or functions of the product you bought may

be different from the manual, depending on the actual model.

Schedule 1: Fault Indicator Definitions

Fault indicator definitions for protocol type 1

Fault description

Fault indicator flashing

Fault indicator

Brake failure

Fault indicator flashing twice

Default phase of motor

Fault indicator flashing 4 times

Motor Hall element failure

Fault indicator flashing 4 times

Handlebar failure

Fault indicator flashing 5 times

Abnormal current

Fault indicator flashing 6 times

Communication receiving failure

Fault indicator flashing 7 times

Communication transmission failure

Fault indicator flashing 8 times

Fault indicator definitions for protocol type 2

Fault description

Fault indicator flashing

Fault indicator

Communication failure

Level L, M and H indicators flashing

Abnormal current

Level L indicator flashing

Brake failure

Level M indicator flashing

Handlebar failure

Level H indicator flashing

Default phase of motor

Level L and H indicators flashing

Motor Hall element failure

Level M and H indicators flashing