YPP6870 Loop-Powered Process Meter 

Instruction Manual 

4

 

Table of Contents 

INTRODUCTION ---------------------------------------------------------------------- 3

 

ORDERING INFORMATION ------------------------------------------------------- 3

 

SPECIFICATIONS -------------------------------------------------------------------- 5

 

General ------------------------------------------------------------------------------------------- 5

 

Input ----------------------------------------------------------------------------------------------- 6

 

Product Ratings and Approvals --------------------------------------------------------- 7

 

Electromagnetic Compatibility ----------------------------------------------------------- 8

 

SAFETY INFORMATION ----------------------------------------------------------- 8

 

INSTALLATION ----------------------------------------------------------------------- 9

 

Unpacking ------------------------------------------------------------------------------------- 10

 

Pre-Installed Conduit Plug --------------------------------------------------------------- 10

 

Mounting --------------------------------------------------------------------------------------- 10

 

Cover Jam Screw --------------------------------------------------------------------------- 10

 

Connections ---------------------------------------------------------------------------------- 11

 

Connections & Wiring Diagrams ............................................................... 12

 

SETUP ---------------------------------------------------------------------------------- 13

 

Scaling Controls and Display ----------------------------------------------------------- 13

 

Setting Up the Meter ----------------------------------------------------------------------- 14

 

Calibrating the Meter ................................................................................ 14

 

Setting the Decimal Point ......................................................................... 14

 

Factory Defaults & User Settings ----------------------------------------------------- 15

 

TROUBLESHOOTING ------------------------------------------------------------- 16

 

Troubleshooting Tips ---------------------------------------------------------------------- 16

 

MOUNTING DIMENSIONS -------------------------------------------------------- 17

 

EC DECLARATION OF CONFORMITY --------------------------------------- 19

 

 

Table of Figures

 

Figure 1. YPP6870 Connectors ............................................................... 11

 

Figure 2. YPP6870 Input Connections without Backlight ..................... 12

 

Figure 3. YPP6870 Input Connections with Loop-Powered Backlight . 12

 

Figure 4. Enclosure Dimensions – Front View ...................................... 17

 

Figure 5. Enclosure Dimensions – Side Cross Section View ............... 18

 

 

Содержание YPP6870

Страница 1: ...P6870 EXPLOSION PROOF LOOP POWERED PROCESS METER 4 20 mA input 1 V drop 4 V with Backlight 3 Digits LCD 1 High Loop Powered Backlight Option HART Protocol Transparent Explosion Proof IP68 NEMA 4X Encl...

Страница 2: ...a Corporation of America shall not be held liable for damages resulting from such improper use Failure to follow installation guidelines could result in death or serious injury Make sure only qualifie...

Страница 3: ...ront mounted control dials with no complex or difficult to read programming menus necessary for setup The numeric display will read from 1999 to 1999 over a 2000 count user adjustable scaling span The...

Страница 4: ...ons Wiring Diagrams 12 SETUP 13 Scaling Controls and Display 13 Setting Up the Meter 14 Calibrating the Meter 14 Setting the Decimal Point 14 Factory Defaults User Settings 15 TROUBLESHOOTING 16 Troub...

Страница 5: ...rature range 40 to 75 C Storage temperature range 40 to 75 C Relative humidity 0 to 90 non condensing CONNECTIONS Screw terminals accept 12 to 22 AWG wire ENCLOSURE Explosion proof die cast aluminum w...

Страница 6: ...MAL POINT User selectable decimal point CALIBRATION RANGE 4 mA input 1000 to 1000 20 mA between 20 and 2000 counts greater than 4 mA display Two point linear display span MAXIMUM VOLTAGE DROP Without...

Страница 7: ...IECEx Ex d IIC T6 Gb Ex tb IIIC T85 C Db IP68 Ta 40 C to 75 C Certificate number IECEx SIR 13 0042X Special Conditions for Safe Use Use suitably certified and dimensioned cable entry device and or pl...

Страница 8: ...3 V 0 15 80 MHz 1 kHz 80 AM SAFETY INFORMATION WARNINGS Read complete instructions prior to installation and operation of the meter Installation and service should be performed only by trained service...

Страница 9: ...SA 22 1 All input circuits must be derived from a CSA approved Class 2 source For European Community The YPP6870 must be installed in accordance with the ATEX directive 94 9 EC and the product certifi...

Страница 10: ...the pre installed conduit plug is removed or replaced all relevant hazardous area guidelines must be followed for its installation or replacement conduit Mounting The YPP6870 has two slotted mounting...

Страница 11: ...display module Signal connections are made to a three terminal connector on the rear of the display module Grounding connections are made to the two ground screws provided on the base one internal an...

Страница 12: ...l earth grounding screw The 4 20 mA input with no backlight has a maximum voltage drop of 1 V and is wired as shown in Figure 2 The loop powered backlight configuration requires a total maximum voltag...

Страница 13: ...isplay module that are accessed when the meter cover is removed Setup is performed using a 4 20 mA signal source and scaling the 4 and 20 mA readings using the control dials Scaling Controls and Displ...

Страница 14: ...ation procedure by making minor adjustments to the LO and HI controls as necessary Minimum Maximum Input Span A minimum input span of 20 counts is required between a 4 mA and 20 mA input A maximum inp...

Страница 15: ...of the programmable parameters on the meter Next to the factory setting the user may record the new setting for the particular application Model ______________ S N _______________ Date _________ Para...

Страница 16: ...te display unsteady during calibration Adjust LO FINE or HI FINE controls to fine tune the display Meter displays 1 on the left most digit location Check signal level is not over range Dial down the H...

Страница 17: ...YPP6870 Loop Powered Process Meter Instruction Manual 17 MOUNTING DIMENSIONS All units inches mm 3 35 85 1 2 25 57 1 0 32 8 2 5 65 143 5 5 25 133 4 Figure 4 Enclosure Dimensions Front View...

Страница 18: ...s Meter Instruction Manual 18 3 35 85 0 4 15 105 5 3 22 81 9 4 86 123 5 Figure 5 Enclosure Dimensions Side Cross Section View Note The supplied conduit plug may extend up to 0 6 in 15 mm from the cond...

Страница 19: ...ton Chester CH4 9JN England EC Type Examination Certificate Sira 13ATEX1121X Quality Assurance Notification No ITS12ATEXQ7640 Compliance with Standards Product Markings EN 60079 0 2009 II 2 G D EN 600...

Страница 20: ...YPP6870 Loop Powered Process Meter Instruction Manual LIM6870YK_B 10 13...

Отзывы: