HART

®

 Communications with the YHC 4150X 

 

Overview 

The YHC 4150X HART communicator provides device specific HART communication functions that 
allow the user to poll, configure and maintain supported HART field devices.  The YHC uses Universal, 
Common Practice and Device Specific commands to facilitate communication with a HART field device.  
Use the YHC to commission devices, for operational re-configuration needs, or maintain devices through 
analog and sensor trim adjustments and many other features.  
The YHC will communicate with any HART device through Universal and Common Practice Commands 
using the standard Generic DOF (Device Object File) but must have the DOF for a specific HART device 
installed before it can execute Device Specific Commands.  Consult the large and growing list of available 
DOFs at  

http://dpcupdates.1911mptdofs.com/past.aspx

 .  When HART device support for new devices 

becomes available, the YHC can be easily field updated via Internet downloads. 
 

Warning:  To avoid damage to a PC serial port, do not connect the YHC’s HART leads to an AC powered 
HART device while the YHC is on AC power and a serial cable is connected to a PC. Yokogawa 
recommends disconnecting the HART leads from the YHC prior to any communication activity. 

HART Commands 

Three HART command types are used by the YHC to communicate with HART field devices. First, 

Universal Commands

 are primarily used to identify a field device by its model number and tag number and 

to read process data from the device. This communication is referred to as “polling”. The YHC can poll any 
Hart Device. Second, 

Common Practice Commands

 are used for calibration and maintenance functions that 

are common to many devices. An example of this would be trims or adjustments for the devices’ analog 
outputs. Third, 

Device Specific Commands

 are used to handle functions that are unique to a particular device 

or manufacturer. Examples of these commands include sensor zero, sensor trim, calibration curve 
characterization, density inputs required for calculations made by the HART device or other configuration 
functions unique to the specific device.   

 
 
HART Connections 

HART connections are made using two standard banana jacks (3/4” center) located at the top end of the 
YHC.  Refer to the following diagram.  Polarity is not a concern for HART connections, therefore, both jack 
collars are black.  Yokogawa supplies a HART lead kit (P/N ZA900529-00014) complete with mini-grabber 
connections and a 250 Ω load resistor with each model YHC. 

 

 

 

For low load loops (less than 250 Ω), a 250 Ω resistor may be needed in the loop to insure reliable HART 
communications.  Yokogawa supplies a 250 Ω load resistor in the form of a standard adaptor (P/N 
ZA36821).  Refer to the following diagram for connection details. 

YHC 4150X with HART

®

 

HART

®

 connections are standard 

banana jacks (3/4” center) 

 

Содержание YHC4150X

Страница 1: ...Yokogawa YHC4150X Manual Get Pricing Availability at ApexWaves com Call Today 1 800 915 6216 Email sales apexwaves com https www apexwaves com analyzers yokogawa yhc4150x series YHC4150X...

Страница 2: ...Yokogawa Corporation of America 2 Dart Road Newnan GA 30265 770 254 0400 IM 61A YHC1 E A 2nd Edition June 2010 Users Manual YHC 4150X HART Communicator Model YHC 4150X Series HART Communicator...

Страница 3: ...merica directly by phone at 800 888 6400 or by e mail at info us yokogawa com Direct all assistance inquiries to the Meters and Instruments Group HART is a registered trademark of the HART Communicati...

Страница 4: ...Configurations Settings 8 1 Users 8 2 Applications 8 3 Lockouts Lockout PV Prompt setting View Lockout Details 8 Lockout Code 9 Disable Lockout 9 Changing Lockout Code 9 4 Clock Timers 9 1 Clock Edit...

Страница 5: ...us Message 21 Save Send Configuration Functions 21 DOF Memory Maintenance 22 Documenting HART Configurations with Yokogawa DMS Software 23 YHC 4150X Device Specific Generic HART Communication 23 Using...

Страница 6: ...f approved YHCs and applicable restrictions DISPLAY OVERVIEW The display of the YHC is a 128 x 128 pixel graphic display with backlight Viewable area is 2 6 x 2 6 for 13 viewable message lines The dis...

Страница 7: ...ween two separate functions as needed to facilitate data entry Soft key functions change depending on the operating mode Soft key definitions are displayed at the bottom of the LCD just above their re...

Страница 8: ...e LCD display for ambient lighting and user preferences at any time and in any operating mode Pressing and holding this key cycles through all available contrast settings After adjusting Display Contr...

Страница 9: ...ay are Soft Keys The specific functions of these keys change depending on the operating mode of the YHC Present definitions are displayed at the bottom of the YHC display Whenever possible the two Sof...

Страница 10: ...g power When the YHC is used with the optional AC adapter P N Z9B000007 the battery circuit is bypassed and a wall plug icon replaces the battery icon on the display header For AC power use the AC ada...

Страница 11: ...xt page of a list press and then the PgDn soft key To retreat to the prior page press and then PgUp PgUp and PgDn soft keys remain active until the Up or Down soft key is used or until is pressed agai...

Страница 12: ...ion will be indicated when line three changes to Device 0 Online 2 2 Select Online Setup if properly connected HART device is setup for Multidrop loop or Burst Mode operation device address 0 The YHC...

Страница 13: ...at a supervisor may wish to control The functions included are used to set up the YHC for normal use change online HART device configurations create offline HART device configurations update the insta...

Страница 14: ...eys of the YHC will not work here Use the Increment Decrement and Next Soft Keys to input a lockout code value Alternatively you may use the green keys for Increment and Decrement functions When you a...

Страница 15: ...date number of DOFs loaded with corresponding free memory space and number of HART configurations saved with corresponding free memory space 2 Battery shows present battery setting and optimizes the b...

Страница 16: ...gin automatically If address 0 is not found the YHC automatically asks for direction select Multi soft key to start a multi drop poll from address 1 15 or select Retry soft key to try to find address...

Страница 17: ...teries at once with all alkaline cells Do not mix alkaline batteries with each other or with other battery types Battery replacement is recommended when the Replace Batteries notice is posted on the d...

Страница 18: ...ult from explosions Do not make any connection to the YHC s Dongle connector while in a hazardous area Use the connector Dongle only in non hazardous areas 2 HART Jacks Lead Set All YHC models are equ...

Страница 19: ...ith new or mix batteries from different manufacturers DO NOT replace batteries while in explosive or hazardous atmospheres DO NOT use any battery type other than those listed on the Intrinsic Safe Con...

Страница 20: ...vity HART Commands Three HART command types are used by the YHC to communicate with HART field devices First Universal Commands are primarily used to identify a field device by its model number and ta...

Страница 21: ...ice is connected and attempts to establish HART communications this is the factory default Auto poll function When a device with address zero is found the YHC provides feedback to the user and starts...

Страница 22: ...ds with address 15 All addresses on the loop will be displayed on the YHC s screen The address of interest can be selected from the list to launch HART communication with that device This Digital Poll...

Страница 23: ...e Name or by stepping through all Devices one at a time Use the soft key controls to move through the list Pressing the key changes soft key definitions Down and Up to PgUp and PgDn To quickly advance...

Страница 24: ...xisting configuration and includes only the edited parameters MVar Primary Cfg for multivariable devices Primary Variable configuration MVar Sub Config for multivariable devices Sub configuration seco...

Страница 25: ...tructure for the connected device Consult the device manual for menu structure details YHC features two unique online features for added convenience to the user 1 Live HART connection monitor YHC disp...

Страница 26: ...ility of the DOF needed by going to http dpcupdates 1911mptdofs com past aspx Sort the list by clicking on any column header For download instructions see the DOF Firmware Download Site section of thi...

Страница 27: ...ght indicates that only 20 of DOF memory is free This indicates fragmentation To optimize DOF flash memory it is necessary to delete all DOFs and then reload them all in one session Connect the YHC to...

Страница 28: ...with any HART device using Universal and Common Practice commands to poll configure and maintain HART devices Specific functions supported include most polling tagging device configuration and trim op...

Страница 29: ...nder Subscriber Options Firmware updates are free of charge DOFs are available by subscription A list of currently available DOF s for HART device communication can be viewed at the http dpcupdates 19...

Страница 30: ...ications and then Port to select COM port C Dongle and RS 232 Cable are connected to the YHC and the unit is turned on Note HART communication cannot occur while communicating using the RS 232 connect...

Страница 31: ...ownload page for bulk downloads Select individual files for downloading from a list of downloadable files including DPC Manager Utility YHC Firmware and DOF s by locating the file name of interest wit...

Страница 32: ...ettings in the toolbar and select Advance Settings To report any difficulties with downloading operations please contact Yokogawa at 770 254 0400 or Info us yokogawa com 8 Use the browser button to na...

Страница 33: ...ll be provided by the Yokogawa Repair Department when you call fax or e mail your information An RA number must accompany all incoming packages to insure proper tracking processing and repair work To...

Страница 34: ...ERY LIFE Approximate 60 hours using AA alkaline batteries without backlight 27 hours using AA alkaline batteries with backlight TEMPERATURE SPECIFICATIONS Storage 40 F to 140 F 40 C to 60 C Operating...

Страница 35: ...ACCESSORIES LIST 4150 7R Protective red boot provides degree of protection against drop related damage slip on A900529 00014 HART Test Lead Kit included w YHC standard banana plugs mini grabbers 250...

Страница 36: ...Yokogawa Corporation of America 2 Dart Road Newnan GA 30265 770 254 0400 IM 61A YHC1 E A 1st Edition Feb 2008 Page 31 of 34 Intrinsic Safety Control Drawing...

Страница 37: ...als Model YHC 4150X series Certifying Agency UL International DEMKO A S Testing Certification 0539 P O Box 514 Lyskaer 8 DK 2730 Herlev Denmark This Declaration is based on Compliance with the followi...

Страница 38: ...Damping Value Units Analog Alarm Analog Trim Menu 4mA Analog Trim 20mA Analog Trim DAC Trim Loop Test Scaled DAC Trim Revisions HART Revision Device Revision Software Revision Final Assbly Number Basi...

Страница 39: ...ent Material Flange Type Remote Seal Isolator Material Flange Size Number of Remote Universal Revision Transmitter Revision Software Tag Date Descriptor Message ASC Model Ext SW Mode Revisions Const M...

Отзывы: