4-5
IM 707235-01E
Specification
4
4.3
General Specifications
Safety Standards
Complies with CSA C22.2 No.1010.1 and EN61010-1, conforms to JIS C1010-1
• Overvoltage Category CAT I and II
*1
• Pollution Degree 1 and 2
*2
*1 Overvoltage Categories define transient overvoltage levels, including impulse withstand
voltage levels.
Overvoltage Category I: Applies to equipment supplied with electricity from a circuit
containing an overvoltage control device.
Overvoltage Category II: Applies to equipment supplied with electricity from fixed
installations like a distribution board.
*2 Pollution Degree:
Applies to the degree of adhesion of a solid, liquid, or gas which
deteriorates withstand voltage or surface resistivity.
Pollution Degree 1: Applies to closed atmospheres (with no, or only dry, non-conductive
pollution).
Pollution Degree 2: Applies to normal indoor atmospheres (with only non-conductive pollution).
EMC Standard
Emission
Complying Standard
EN55011 Group 1 Class A
This product is a Class A (for industrial environment) product. Operation of this product in
a residential area may cause radio interference in which case the user is required to
correct the interference.
Immunity
Complying Standard
EN61326 Industrial Environment
Testing Condition
Connect with the 3 m coaxial cable (3D2W).
Maximum Measuring Input Cable Length
30 m
Standard Operating Conditions
Ambient temperature: 23
°
C
±
5
°
C
Ambient humidity: 50
±
10% RH
Supply voltage/frequency error: Within 1% of rating
After warm-up time has passed
Warm-up Time
At least 30 minutes
Maximum Allowable Input Voltage
±
60 V (DC + AC peak)
Operating Conditions
Same as those of the measuring station
Storage Conditions
Temperature: –20
°
C to 60
°
C
Humidity: 20% to 80% RH (no condensation)
Power Consumption
12 VA (typical value at 100 V/50 Hz
*3
)
Weight
Approx. 0.8 kg
External Dimensions
Approx. 33(W)
×
243(H)
×
232(D) mm (projections excluded)
Number of Used Slots
1
Standard Accessories
User’s Manual (this manual) (1)
*3 The typical value is a representative or standard value. It is not a warranted value.